Thomas Sanchez

Thomas Sanchez

Auto-generated profile, based on publicly available information

Thomas Sanchez

CIBM Center for Biomedical Imaging, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2024 in Medical Image Analysis
Verified
Journal Article
Open access
TSThomas Sanchez
Thomas Sanchez
OEOscar Esteban
Oscar Esteban
YGYvan Gomez
Yvan Gomez
APAlexandre Pron
Alexandre Pron
Meriam KoobMeriam Koob
Meriam Koob
MCMeritxell Bach Cuadra
Meritxell Bach Cuadra
Fetal brain MRI is becoming an increasingly relevant complement to neurosonography for perinatal diagnosis, allowing fundamental insights into fetal brain development throughout gestation. However, uncontrolled fetal motion and heterogeneity in acquisition protocols lead to data of variable quality, potentially biasing the outcome of subsequent studies. We present FetMRQC, an open-source machine-learning framework for automated image quality assessment and quality control that is robust to domain shifts induced by the heterogeneity of clinical data. FetMRQC extracts an ensemble of quality metrics from unprocessed anatomical MRI and combines them to predict experts' ratings using random forests. We validate our framework on a pioneeringly large and diverse dataset of more than 1600 manually rated fetal brain T2-weighted images from four clinical centers and 13 different scanners. Our study shows that FetMRQC's predictions generalize well to unseen data while being interpretable. FetMRQC is a step towards more robust fetal brain neuroimaging, which has the potential to shed new insights on the developing human brain.

1 September 2019
Verified
Conference Paper
Open access
BGBaran Gozcu
Baran Gozcu
TSThomas Sanchez
Thomas Sanchez
VCVolkan Cevher
Volkan Cevher

10 October 2024
Verified
Book Chapter
Closed access
PDF file
TSThomas Sanchez
Thomas Sanchez
AMAngeline Mihailov
Angeline Mihailov
YGYvan Gomez
Yvan Gomez
GJGerard Martí Juan
Gerard Martí Juan
EEElisenda Eixarch
Elisenda Eixarch
MCMeritxell Bach Cuadra
Meritxell Bach Cuadra

12 October 2023
Verified
Book Chapter
Closed access
PDF file
TSThomas Sanchez
Thomas Sanchez
OEOscar Esteban
Oscar Esteban
YGYvan Gomez
Yvan Gomez
EEElisenda Eixarch
Elisenda Eixarch
MCMeritxell Bach Cuadra
Meritxell Bach Cuadra

16 January 2026 in Medical Image Analysis
Verified
Journal Article
Open access
VZVladyslav Zalevskyi
Vladyslav Zalevskyi
TSThomas Sanchez
Thomas Sanchez
MKMisha Kaandorp
Misha Kaandorp
MRMargaux Roulet
Margaux Roulet
DFDiego Fajardo-Rojas
Diego Fajardo-Rojas
MCMeritxell Bach Cuadra
Meritxell Bach Cuadra
Accurate fetal brain tissue segmentation and biometric measurement are essential for monitoring neurodevelopment and detecting abnormalities in utero. The Fetal Tissue Annotation (FeTA) Challenges have established robust multi-center benchmarks for evaluating state-of-the-art segmentation methods. This paper presents the results of the 2024 challenge edition, which introduced three key innovations. First, we introduced a topology-aware metric based on the Euler characteristic difference (ED) to overcome the performance plateau observed with traditional metrics like Dice or Hausdorff distance (HD), as the performance of the best models in segmentation surpassed the inter-rater variability. While the best teams reached similar scores in Dice (0.81-0.82) and HD95 (2.1-2.3 mm), ED provided greater discriminative power: the winning method achieved an ED of 20.9, representing roughly a 50% improvement over the second- and third-ranked teams despite comparable Dice scores. Second, we introduced a new 0.55T low-field MRI test set, which, when paired with high-quality super-resolution reconstruction, achieved the highest segmentation performance across all test cohorts (Dice=0.86, HD95=1.69, ED=6.26). This provides the first quantitative evidence that low-cost, low-field MRI can match or surpass high-field systems in automated fetal brain segmentation. Third, the new biometry estimation task exposed a clear performance gap: although the best model reached a mean average percentage error (MAPE) of 7.72%, most submissions failed to outperform a simple gestational-age-based linear regression model (MAPE=9.56%), and all remained above inter-rater variability with a MAPE of 5.38%. Finally, by analyzing the top-performing models from FeTA 2024 alongside those from previous challenge editions, we identify ensembles of 3D nnU-Net trained on both real and synthetic data with both image- and anatomy-level augmentations as the most effective approaches for fetal brain segmentation. Our quantitative analysis reveals that acquisition site, super-resolution strategy, and image quality are the primary sources of domain shift, informing recommendations to enhance the robustness and generalizability of automated fetal brain analysis methods.

8 August 2025 in Pediatric Radiology
Verified
Journal Article
Open access
TSThomas Sanchez
Thomas Sanchez
AMAngeline Mihailov
Angeline Mihailov
MKMériam Koob
Mériam Koob
NGNadine Girard
Nadine Girard
AMAurélie Manchon
Aurélie Manchon
MCMeritxell Bach Cuadra
Meritxell Bach Cuadra
Background: Fetal brain MRI is increasingly used to complement ultrasound imaging. Images are processed using complex super-resolution reconstruction pipelines, which may bias biometric and volumetric measurements. Objective: To assess the consistency of 2-dimensional (D) biometric and 3-D volumetric measurements across three hospitals using three widely used super-resolution reconstruction pipelines. Materials and methods: This retrospective multi-centric study used T2-weighted fetal brain MRI scans acquired at three hospitals between 2009 and 2023. MRIs from each subject were reconstructed with each super-resolution reconstruction method, and biometric measurements were performed by four experts. Automated 3-D volumetry was performed using a state-of-the-art segmentation method. A qualitative evaluation assessed the clinicians’ likelihood of using super-resolution reconstructed volumes in their practice. Results: Eighty-four healthy subjects were included. Biometric measurements revealed statistically significant changes that consistently remained below voxel width (0.8 mm; P<0.001). Automated 3-D volumetry revealed small systematic effects (<2.8%; P<0.001). The qualitative evaluation showed systematic differences between super-resolution reconstruction methods for the perception of white matter intensity (P=0.02) and sharpness of the image (P=0.01). Conclusion: Variations in 2-D and 3-D quantitative measurements did not show any large systematic bias when using different super-resolution reconstruction methods for clinical radiological assessment across centers, scanners, and raters.