Zhenxi Ma

Zhenxi Ma

Auto-generated profile, based on publicly available information

Zhenxi Ma

School of Energy and Environment, Southeast University 1 , Nanjing 210096

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in International Journal of Refrigeration
Verified
Journal Article
Closed access
RZRui Zhang
Rui Zhang
ZTZhongyun Tian
Zhongyun Tian
FLFengguo Liu
Fengguo Liu
CTChangfei Tian
Changfei Tian
ZMZhenxi Ma
Zhenxi Ma
LJLeilei Jia
Leilei Jia

11 July 2023 in Thermal Science and Engineering Progress
Verified
Journal Article
Closed access
XZXiao Zhang
Xiao Zhang
LCLiang Cai
Liang Cai
ZMZhenxi Ma
Zhenxi Ma
JLJian Liu
Jian Liu
XZXiaosong Zhang
Xiaosong Zhang

26 March 2023 in International Journal of Green Energy
Verified
Journal Article
Closed access
HGHouchang Gao
Houchang Gao
LCLiang Cai
Liang Cai
YFYing Fang
Ying Fang
ZMZhenxi Ma
Zhenxi Ma
HWHuimin Wang
Huimin Wang
This paper combines the advantages of air source heat pumps and proton exchange membrane fuel cells, and analyses the dynamic performance, environmental benefits, and economic benefits of combined cooling, heating, and power (CCHP) systems combined with energy storage systems applied to residential buildings. The fuel cell voltage and heat model, air source heat pump (ASHP) model, and energy storage system model are developed in MATLAB. The results show that the problem of thermoelectric asynchrony and excess energy wastage can be solved by using the heat-following strategy with a battery and the electric-following strategy with a water tank. With the heat-following strategy in winter, the total thermodynamic efficiency of the system is 1.265, the carbon emission reduction is 6208.6 g, and the initial cost, operation cost, and maintenance cost are 6007$, 11.99$, and 300.35$, respectively. The efficiency of the system with the winter electric-following strategy is 1.284, the emission reduction is 6781.4 g, and the initial cost, operation cost, and maintenance cost are 7202.9$, 11.88$, and 360.14$, respectively. In summer with the electric-following strategy, the thermodynamic efficiency of the system is 1.514; the carbon reduction is 8,033.6 g. The initial cost, operation cost, and maintenance cost are 7,208.3$, 14.84$, and 360.42$.

1 July 2025 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
YGYanyu Gao
Yanyu Gao
ZMZhenxi Ma
Zhenxi Ma
WLWenqing Liang
Wenqing Liang
LCLiang Cai
Liang Cai
High-temperature proton exchange membrane fuel cells have high efficiency, a simple water management system, high tolerance to impurities, and generate high-temperature heat, making them suitable for integrated energy systems (IES). Currently, research on the power allocation strategy of a multi-stack fuel cell system (MFCS) is mostly focused on transportation applications, emphasizing electrical efficiency and hydrogen consumption. However, MFCS often provides heating in IES, necessitating the consideration of thermal efficiency. Additionally, the lifespan of the stack is a major factor affecting the economic cost of the system and must also be incorporated into power allocation strategies. This paper aims to further promote the efficient application of MFCS within IES by proposing a solar-hydrogen coupled IES for office buildings. Considering the overall efficiency and stack lifespan, a segmented-optimal point operation allocation strategy is proposed. Furthermore, a coordinated operation strategy for the system's equipment is designed. MATLAB modeling is employed to configure the installed capacity of each equipment and calculate the operational results. The results show that the optimal number of stacks for this system is 5. Compared to an IES using a single-stack fuel cell system, MFCS-IES reduces the specific exergy cost by 9.15%, with a notable 56.0% decrease in stack replacement costs. During the operation of the stack, the thermal efficiency increased by an average of 13.27%, and the overall efficiency improved by 7.73%. This strategy avoids operation of the stack in low-power regions and reduces load fluctuations. As a result, the average degradation rate of the stack decreases by 50.44% in the MFCS, demonstrating significant performance enhancement.