We present experimental and theoretical results on a new interferometer topology that nests a SU(2) interferometer, e.g., a Mach-Zehnder or Michelson interferometer, inside a SU(1,1) interferometer, i.e., a Mach-Zehnder interferometer with parametric amplifiers in place of beam splitters. This SU(2)-in-SU(1,1) nested interferometer (SISNI) simultaneously achieves a high signal-to-noise ratio (SNR), sensitivity beyond the standard quantum limit (SQL) and tolerance to photon losses external to the interferometer, e.g., in detectors. We implement a SISNI using parametric amplification by four-wave mixing (FWM) in Rb vapor and a laser-fed Mach-Zehnder SU(2) interferometer. We observe path-length sensitivity with SNR 2.2 dB beyond the SQL at power levels (and thus SNR) 2 orders of magnitude beyond those of previous loss-tolerant interferometers. We find experimentally the optimal FWM gains and find agreement with a minimal quantum noise model for the FWM process. The results suggest ways to boost the in-practice sensitivity of high-power interferometers, e.g., gravitational wave interferometers, and may enable high-sensitivity, quantum-enhanced interferometry at wavelengths for which efficient detectors are not available.
In the past few decades, optical magnetometry has experienced remarkable development and reached to an outstanding sensitivity. For magnetometry based on optical readout of atomic ensemble, the fundamental limitation of sensitivity is restricted by spin projection noise and photon shot noise. Meanwhile, in practical applications, ambient magnetic noise also greatly limits the sensitivity. To achieve the best sensitivity, it is essential to find an efficacious way to eliminate the noises from different sources, simultaneously. Here, we demonstrate a quantum magnetic gradiometer with sub-shot-noise sensitivity using entangled twin beams with differential detection. The quantum enhancement spans a frequency range from 7 Hz to 6 MHz with maximum squeezing of 5.5 dB below the quantum noise limit. The sensitivity of gradiometer reaches 18 fT/cm at 20 Hz. Our study inspires future possibilities to use quantum-enhanced technology in developing sensitive magnetometry for practical applications in noisy and physically demanding environments.
With the help of quantum entanglement, quantum dense metrology (QDM) is a technique that can make joint estimates of two conjugate quantities such as phase and amplitude modulations of an optical field, with an accuracy beating the standard quantum limit simultaneously. SU(1,1) interferometers (SUIs) can realize QDM with detection loss tolerance but is limited in absolute sensitivity. Here, we present a QDM scheme with a linear or SU(2) interferometer nested inside an SUI. By using a degenerate SUI and controlling the phase angle of the phase-sensitive amplifiers in the SUI, we can achieve the optimum quantum enhancement in the measurement precision of an arbitrary mixture of phase and amplitude modulation.
Rydberg atoms have shown remarkable performance in sensing microwave fields. The sensitivity of such an electrometer based on optical readout of the atomic ensemble has been demonstrated to approach the photon-shot-noise limit. However, the sensitivity cannot be promoted infinitely by increasing the power of the probe light due to the increased collision rates and power broadening. Compared with classical light, the use of quantum light may lead to a better sensitivity with a lower number of photons. In this paper, we exploit entanglement in a microwave-dressed Rydberg electrometer to suppress the fluctuation of noise. The results show a sensitivity enhancement that beats the shot-noise limit in both cold- and hot-atom schemes. Through optimizing the transmission of the optical readout, our quantum advantage can be maintained with differing absorptive indexes of the atomic vapor, which makes it possible to apply a quantum light source in the absorptive electrometer.
Quantum-correlated interferometer is an emerging tool in quantum technology that offers classical-limit-breaking phase sensitivity. However, to date, there exists a configurational bottleneck for its practicability due to the low phase-sensing power limited by the current detection strategies. Here, we establish an innovative development termed as “quantum twin interferometer” with dual pairs of entangled twin beams arranged in the parallel configuration, allowing full exploitation of the quantum resource through the configuration of entangled detection. We observe the distributed phase sensing with 3-decibel quantum noise reduction in phase-sensing power at the level of milliwatts, which advances the record of signal-to-noise ratio so far achieved in photon-correlated interferometers by three orders of magnitude. The developed techniques in this work can be used to revolutionize a diversity of quantum devices requiring phase measurement.
Chiral discrimination of enantiomeric biomolecules is vital in chemistry, biology, and medicine. Conventional methods, relying on circularly polarized light, face weak chiroptical signals and potential photodamage. Despite extensive efforts to improve sensitivity under low-photon exposure, classical chiral probes remain fundamentally bound by the shot noise limit due to quantum fluctuations. To beat these limitations, we demonstrate quantum-elevated chiral discrimination using continuous-variable polarization-entangled states as moderate–photon flux, high-sensitivity, quantum noise–squeezed chiral probes. We achieve a 5-decibel improvement beyond the shot noise limit in distinguishing l - and d -amino acids in liquid phase. This nondestructive, biocompatible protocol enables high-sensitivity chiral analysis, with broad implications for drug development, biochemical research, environmental monitoring, and asymmetric synthesis.