Mykola Kirilyuk

Mykola Kirilyuk

Auto-generated profile, based on publicly available information

Mykola Kirilyuk

Івано-Франківський національний медичний університет, кафедра ортопедичної стоматології, м. Івано-Франківськ, Україна

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2026 in Ukrainian Dental Almanac
Verified
Journal Article
Open access
VTV.M. Tytyk
V.M. Tytyk
RKRoman Kutsyk
Roman Kutsyk
ZOZ.R. Ozhogan
Z.R. Ozhogan
ROR.Z. Ozhohan
R.Z. Ozhohan
MKM.I. Kyrylyuk
M.I. Kyrylyuk
SPS.V. Petryshyn
S.V. Petryshyn
To reduce microbial adhesion and improve the antimicrobial properties of dental materials, surface-modification strategies have been proposed, including mechanical polishing, bioactive chemical coatings, nanocomposite surface treatment, and advanced CAD/CAM technologies. The aim of this study was to compare the adhesion of a broad spectrum of bacteria and fungi of the oral microflora to acrylic and elastic denture base plastics coated with Optiglaze, as a measure to prevent biofilm formation. Materials and Methods. The study used specimens 2 mm thick and 1 cm² in area, fabricated from the acrylic denture base resin Villacryl (40 specimens) and the elastic resin Acron (40 specimens), as well as a control material—glass (40 specimens). After sandblasting, a thin layer of Optiglaze (GC Corp., Japan) was applied to all surfaces of each specimen in three groups (40 specimens per group), polymerized with an LED curing light, and sterilized by X-ray irradiation. The study employed strains of opportunistic microorganisms representing facultative anaerobic transient microflora of the oral cavity. Microbial adhesive capacity was assessed in an in vitro experiment using a modified Lassila L. method, which involves ultrasonic elution of cells attached to the surface followed by counting colony-forming units (CFU). Results. Optiglaze significantly reduced microbial adhesion on Villacryl and glass. Exceptions included S. epidermidis and P. aeruginosa, for which no reduction was observed, and C. lipolytica, for which the reduction was partial. Two-way ANOVA for each strain demonstrated significant main effects of both material type and Optiglaze coating for most microorganisms. A significant material × coating interaction was observed for S. aureus (MSSA and MRSA), S. gordonii, E. coli, A. baumannii, C. albicans, and C. lipolytica, indicating that the effect of Optiglaze depends on the base material. Overall, Optiglaze significantly decreased adhesion on all tested materials, with the strongest effect observed on Villacryl (Holm p = 3.99 × 10⁻¹⁰; BH p = 3.99 × 10⁻¹⁰), and a moderate effect on Acron (Holm p = 2.41 × 10⁻⁶; BH p = 1.81 × 10⁻⁶) and glass (Holm/BH p = 1.63 × 10⁻⁵). Conclusion. The type of denture base material and the presence of the Optiglaze coating significantly affect the adhesion of oral microbial strains to the surface of experimental specimens. The Optiglaze protective coating reduces microbial adhesion on all three materials: most pronounced on glass (almost all strains showed significant differences), and moderate on Villacryl and Acron.

1 July 2025 in Art of Medicine
Verified
Journal Article
Open access
PDF file
АБА. В. Бібен
А. В. Бібен
ЗОЗ. Р. Ожоган
З. Р. Ожоган
МКМ. І. Кирилюк
М. І. Кирилюк
ОШО. В. Шутак
О. В. Шутак
ЛМЛ. В. Мізюк
Л. В. Мізюк
ІВІ. В. Виклюк
І. В. Виклюк
Low clinical crowns of teeth are a pathological process characterized by a pronounced loss of enamel and dentin, accompanied by functional and aesthetic disorders of the dentofacial system. Despite the rapid development of modern dentistry, pathological tooth erosion remains a difficult problem for treatment, having significant variability depending on the patient's age, type of bite, presence, size and localization of dentition defects, degree of erosion and associated complications. Treatment of this pathology is two-stage, with preliminary preparation for prosthetics and increasing the interalveolar height using temporary, and at the final stage of treatment and permanent orthopedic structures. Acrylic or fixed dentures are most often used as temporary orthopedic structures, the second stage using permanent fixed dentures is characterized by a great variability of orthopedic structures. CAD/CAM technology allows for the high-precision manufacture of orthopedic fixed prostheses, ensuring an incomparably high, compared to traditional manufacturing methods, congruence of the surface of the prepared tooth and the artificial crown, therefore we are increasingly using half crowns and occlusal overlays for the treatment of pathological attrition of teeth. Regarding the choice of structural material for half crowns, the most widely used are press ceramics and zirconium dioxide. However, zirconium dioxide has significantly higher tribological characteristics. In addition, zirconium dioxide has high aesthetic, biological properties, and is able to restrain the spread of microcracks under excessive loads. It is well known that a protective coating of zirconium dioxide eliminates the manifestations of galvanosis and galvanism in the oral cavity. Based on the above studies, we recommend using half crowns of zirconium dioxide for the treatment of pathological attrition of teeth.

30 December 2024 in Archive of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ZOZinoviy Ozhogan
Zinoviy Ozhogan
IKIryna Kumgyr
Iryna Kumgyr
LMLidiia Mizyuk
Lidiia Mizyuk
VLVolodymyr Levko
Volodymyr Levko
YKYurii Klymiuk
Yurii Klymiuk
IVIhor Viklyuk
Ihor Viklyuk
To the presence healthy teeth is an integral part of human health. Their partial or complete loss can have complex consequences for our functioning and quality of life. There are a number of factors that lead to tooth loss. In particular, genetic factors, periodontal diseases, caries complications, poor diet and bad habits. In some cases, tooth loss can be hereditary, caused by an increased tendency to develop caries or periodontal diseases. The presence of various abnormalities in the development of teeth can also be the reason for their loss in the future. Furthermore, the most common methods of treating partial defects of the dentition combined with periodontal tissue diseases are fixed partial and adhesive metal-ceramic prostheses, the design of which involves significant preparation of the hard tissues of the teeth that limit the defect. An adhesive metal-ceramic prosthesis, the design of which consists of an artificial tooth and fixing elements made in the form of cores or overlays, completely covered with ceramic material, has a number of disadvantages and limited indications for use. For the proposed adhesive splint prosthesis allows minimally dissection of supporting teeth hard tissues; at the expense of high accuracy production maybe to be used for minor deformations of the dentition, if present carious and non-carious lesions; due to high bioinertness recommended construction of choice for periodontal tissue diseases. The purpose of the study. To increase the effectiveness of orthopedic treatment of patients with chronic periodontitis of moderate severity and to substantiate the method of splinting mobile teeth in the presence of small dentition defects in the frontal area, taking into account the anatomical features, functionality and aesthetic appearance of the structure. Materials and methods.​ With the help of adhesive splint prosthesis are made of high-tech polymer PEEK-"Bio Hpp" proposed a new approach to the problem of treating small dentition defects in the frontal area. A comparative analysis was conducted and the advantages of the proposed design with similar prostheses were proven. Research results. The obtained results indicate that the proposed design allows for splinting and restoration of the aesthetic appearance and integrity of the dentition, preventing the occurrence of deformations and ensuring the functionality of the maxillofacial system. Conclusions 1. The proposed design of the adhesive splint prosthesis made of high-tech polymer PEEK-"Bio Hpp" allows you to restore the integrity of the dentitions in the presence of small included defects in the frontal area and provides a good splinting result. 2. Production of a frame from high-tech polymer PEEK-"Bio Hpp”, allows to significantly reduce the depth of preparation of teeth hard tissues, providing an excellent aesthetic result, which makes it possible to significantly expand the indications for use. 3. The long-term results of the treatment indicate the absence of marginal staining at the border of the hard tissue of the tooth - indirect restoration, i.e. marginal detachment, which provides good aesthetics, functional integrity of the structure and a satisfactory splinting result.