16 October 2020 in IEEE Transactions on Instrumentation and Measurement
To solve the problems of low resolution, weak anti-noise performance, and imprecise fault location in discharge recognition of ultraviolet imaging, an intelligent state recognition method of surface discharge based on visible images and machine learning is proposed in this paper. A visible image library of surface discharge(AC) under different experimental conditions was established, and the chromatic, grayscale, and morphological features of images were extracted. The image library was divided into 4 stages by clustering. Combined with spectrum correlation experiments, the physical meaning of the division results was explained. Supervised learning algorithms, including classic algorithms and deep learning, were used to train intelligent recognition models. The results showed that models based on chromatic features had a higher accuracy for recognition; the accuracy of artificial neural networks reached 0.982, which was obviously higher than that of classical learning algorithms (0.886). The results show that visible images can be used for the state recognition of surface discharges effectively. The application of machine learning ensures high efficiency and accuracy. This method will enable state recognition and fault location to be completed simultaneously.
22 April 2020 in IEEE Sensors Journal
Discharge is a process, which involves changes in multiple species, and it is important for researchers to be able to describe changes in discharge status holistically. In this study, we applied AC and DC high voltage power sources to a short-gap needle-plane device in an atmospheric environment. We propose two new corona diagnosis methods based on spectral data and visible images. The experimental results demonstrate that, in the RGB system, the proportion of the blue component in AC corona images has the characteristic of decrease-stable-increase with voltage, and the corresponding result of the spectra is stable-increase. In the XYZ system, the AC corona chromaticity coordinates of both images and spectra demonstrate a linear fitting result with the voltage, and the image results contain a retracement process, showing shows the increase-stable-decrease trend of chromaticity coordinates x and y, which correlates well with oscilloscope results. The difference between the image and spectra results indicates that, compared to the spectra, high-resolution visible images are more sensitive to imperceptible changes in colorimetry information. The change of DC corona colorimetry characteristics can illustrate the change in AC corona colorimetry characteristics. Additionally, the dominant wavelength is proven to reflect the discharge species, and can reflect the vibrational temperatures. To the best of our knowledge, this paper represents the first attempt to systematically introduce colorimetry theory into discharge images and spectra. We successfully obtained colorimetric indicators with the linearity and low-dimension characteristics, which correspond well with known physical parameters.
13 September 2021 in IEEE Transactions on Instrumentation and Measurement
Thermal radiant energy of metal surfaces is weak in visible bands at normal temperatures, making it difficult to perform non-contact temperature measurements by visible images based on thermal radiation principle. However, this paper proposed an intelligent temperature measurement method of metal surfaces at normal temperatures in sunlight based on thermal-modulated reflection. A digital camera was used to take photos of iron, aluminum alloy, and copper, with their temperature ranging from 26.0°C to 100.0°C. These images composed three corresponding image libraries of these materials. For each image in each library, two kinds of statistical features, RGB gray level histograms (RGB-GLHs) and deep semantic chromatic features (DSCFs), were extracted and labeled by the image’s corresponding measured temperature, forming two kinds of Feature-Label datasets of the image library. For each library, both kinds of Feature-Label datasets were used to train machine learning (ML) models for temperature prediction. Besides, a baseline model, Resnet50, was trained for temperature prediction. Results showed that the trained ML models predicted the surface temperature of these materials well. Models trained by DSCFs greatly improved prediction accuracy compared with those trained by RGB-GLHs and Resnet50. The K-Nearest Neighbor models had a mean absolute error under 1.0. Meanwhile, using DSCFs significantly saved the calculation time and data storage spaces. This method would provide a new choice for the temperature measurement of electrical equipment’s metal parts and other cases requiring non-contact measurements.
3 August 2021 in IEEE Sensors Journal
The temperature of metal surfaces at normal temperatures under sunlight can be measured by combining visible images with machine learning (ML). But this method is susceptible to illumination conditions, which causes large errors. To solve this problem, a method of temperature difference measurement based on visible images’ differential chromatic features (DCFs) between two metal surfaces, which are at different temperatures but the same illumination, is proposed in this paper. Through experiments, temperature difference image libraries of brass surfaces under varying illumination are established. DCFs of each image are extracted, and temperature difference between two surfaces is used as the label. Models that can predict the temperature difference between two surfaces are trained by ML. Prediction results show that the mean absolute error of this temperature difference measurement method can be as low as 1.6, decreasing by 42% at most compared with those of simply measuring the surface temperature. The effect of temperature and illumination on visible images’ gray levels is analyzed. And it is concluded that the introduction of a temperature-constant surface provides a reference item for illumination, which helps to weaken the influence of illumination changes and filter out the interference caused by them. This is why the prediction accuracy can be improved by the temperature difference measurement method.