Edward Lamere

Edward Lamere

Auto-generated profile, based on publicly available information

Edward Lamere

Massachusetts Institute of Technology

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in Physical Review C
Verified
Journal Article
Closed access
PDF file
ELE. Lamere
E. Lamere
MCM. Couder
M. Couder
MBM. Beard
M. Beard
ASA. Simon
A. Simon
Antonio SimonettiAntonio Simonetti
Antonio Simonetti
ESE. Stech
E. Stech
Cross sections for 34 proton-induced nuclear reactions on isotopically enriched molybdenum (Mo92,94−98,100) leading to production of Tc92, Tc93m, Tc93g, Tc94m, Tc94g, Tc95m, Tc95g, Tc96m+g, Tc97m, Tc99m, Tc101, Mo91(m+g), Mo93m, Mo99, Nb89m, Nb89g, Nb91m, Nb92m, Nb95m, Nb95g, Nb96, and Nb97m+g were measured in the energy range 8–19 MeV with the activation method using individual irradiations. The experimental data were compared with published data from natural abundance and isotopically enriched targets as well as with the predictions of the nuclear reaction code talys. Special attention was given to the medically relevant Mo100(p,2n)Tc99m and Mo100(p,pn)Mo99 as well as nine reaction cross sections that had not previously been measured in this energy range.

30 March 2020 in medRxiv
Verified
Preprint
Open access
PDF file
ACAvilash Cramer
Avilash Cramer
ETEnze Tian
Enze Tian
SYSherry H. Yu
Sherry H. Yu
MGMitchell Galanek
Mitchell Galanek
ELEdward Lamere
Edward Lamere
MSMichael P. Short
Michael P. Short
The current COVID-19 pandemic has led to a dramatic shortage of masks and other personal protective equipment (PPE) in hospitals around the globe [1]. One component of PPE that is in particular demand are disposable N95 face masks. To alleviate this, many methods of N95 mask sterilization have been studied and proposed with the hope of being able to safely reuse masks [2]. Two major considerations must be made when re-sterilizing masks: (1) the sterilization method effectively kills pathogens, penetrating into the fibers of the mask, and (2) the method does not degrade the operational integrity of the N95 filters. We studied Cobalt-60 ( 60 Co) gamma irradiation as a method of effective sterilization without inducing mask degradation. Significant literature exists supporting the use of gamma radiation as a sterilization method, with viral inactivation of SARS-CoV reported at doses of at most 10 kGy [3], with other studies supporting 5 kGy for many types of viruses [4]. However, concerns have been raised about the radiation damaging the fiber material within the mask, specifically by causing cross-linking of polymers, leading to cracking and degradation during fitting and/or deployment [5, 6]. A set of 3M 8210 and 9105 masks were irradiated using MIT’s 60 Co irradiator. Three masks of each type received 0 kiloGray (kGy), 10 kGy and 50 kGy of approximately 1.3 MeV gamma radiation from the circular cobalt sources, at a dose rate of 2.2kGy per hour. Following this sterilization procedure, the irradiated masks passed a OSHA Gerson Qualitative Fit Test QLFT 50 (saccharin apparatus) [7] when donned correctly, performed at the Brigham and Women’s Hospital, in a blinded study repeated in triplicate. However, the masks’ filtration of 0.3 µ m particles was significantly degraded, even at 10 kGy. These results suggest against gamma, and possibly all ionizing radiation, as a method of disposable N95 sterilization. Even more importantly, they argue against using the qualitative fit test alone to assess mask integrity.