Hyunki In

Hyunki In

Auto-generated profile, based on publicly available information

Hyunki In

Center for Healthcare Robotics, Korea Institute of Science and Technology, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2022 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
HCHo Seon Choi
Ho Seon Choi
YBYoon Su Baek
Yoon Su Baek
HIHyunki In
Hyunki In
Background: Although the ankle strategy is important for achieving frontal plane stability during one-leg stance, previously developed powered ankle–foot orthoses (PAFOs) did not involve ankle strategies because of hardware limitations. Weakness of movement in frontal plane is a factor that deteriorates gait stability and increases fall risk so it should not be overlooked in rehabilitation. Therefore, we used PAFO with subtalar joint for frontal plane movement and tried to confirm that the existence of it is important in balancing through clinical experiments. Methods: We developed a proportional CoP controller to assist ankle strategy or stabilizing moment and enhance eversion to compensate for the tilting moment with 2 dof PAFO. It was true experimental study, and we recruited seven healthy subjects (30 ± 4 years) who did not experience any gait abnormality participated in walking experiments for evaluating the immediate effect of subtalar joint of PAFO on their gait stability. They walked on the treadmill with several cases of controllers for data acquisitions. Indices of gait stability and electromyography for muscle activity were measured and Wilcoxon signed-rank tests were used to identify meaningful changes. Results: We found that subjects were most stable during walking (in terms of largest Lyapunov exponents, p < 0.008) with the assistance of the PAFO when their electromyographic activity was the most reduced (p < 0.008), although postural sway increased when a proportional CoP controller was used to assist the ankle strategy (p < 0.008). Other indices of gait stability, kinematic variability, showed no difference between the powered and unpowered conditions (p > 0.008). The results of the correlation analysis indicate that the actuator of the PAFO enhanced eversion and preserved the location of the CoP in the medial direction so that gait stability was not negatively affected or improved. Conclusions: We verified that the developed 2 dof PAFO assists the ankle strategy by compensating for the tilting moment with proportional CoP controller and that wearer can walk in a stable state when the orthosis provides power for reducing muscle activity. This result is meaningful because an ankle strategy should be considered in the development of PAFOs for enhancing or even rehabilitating proprioception. Trial registration 7001988-202003-HR-833-03

4 October 2023 in IEEE Access
Verified
Journal Article
Open access
MLMyungjoong Lee
Myungjoong Lee
HIHyunki In
Hyunki In
Considering the ambulatory principles for the blind and visually impaired individuals (BVI), who encounter difficulties in independent walking and wayfinding, the acquisition of diverse types of information is required. For independent walking, the spatial and status information are required in addition to directional information. However, delivering information of several types poses a problem because it decreases the perception rate of the information. To address this problem, we applied a strategy that configures the group of vibrotactile information by combining both stationary and moving tactons, as opposed to using stationary or moving alone. In this study, we introduce a novel wrist-worn tactile display with eight vibrators, which can deliver easily distinguishable directional, spatial, and status information. For improving the recognition rate of information provided, the vibration patterns were categorized according to spatial characteristics and were provided to express the different types of information. Through the preliminary study, it was confirmed that the capacity of information transmission improved significantly when employing a combination of stationary and moving tactons, as opposed to relying solely on stationary or moving tactons. The effectiveness of the proposed device was evaluated through user tests with the blind and visually impaired participants. Overall, the categorized vibrotactile information was quickly identified, and it enabled the blind to walk independently without any pre-learned knowledge about the route.

16 December 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
HCHo Seon Choi
Ho Seon Choi
SLSeung Jun Lee
Seung Jun Lee
HIHyunki In
Hyunki In
Introduction: During tasks like minimally invasive surgery (MIS), various factors can make working environment not be ergonomic, and those situations will accumulate fatigue in the surgeon's muscles which will inevitably lead to poor surgical performance. Therefore, there has been a need for technical solutions to solve this problem and one of the methods is exoskeleton robots.Methods: We designed a passive shoulder exoskeleton whose workspace could be used for MIS to assist the surgeon's movements and performed computational and clinical validation. First, the joint order of the shoulder exoskeleton, which consists of three degrees of freedom, was configured differently from previous studies so that the singularity can be located outside the workspace. And a novel gravity compensation mechanism was developed to replace the existing one, which could no longer be used due to these changes on order of joints. Afterwards, it was computationally verified using statics and kinematics whether sufficient shoulder muscle assistance could be implemented for the entire developed system. Lastly, we manufactured an apparatus that simulated the surgical environment in which the shoulder exoskeleton robot would actually be used, recruited human participants, and conducted an experiment.Results: Through computational validation, we can guess that the developed shoulder exoskeleton can provide 18.14% reduction of muscle activation to the wearers in workspace. And the results of clinical experiments with human subjects show that activation of deltoid posterior, medial and anterior decreased with average −8.33%, −14.55%, and −21.0%, respectively during MIS-simulated tasks with developed shoulder exoskeleton than without it. And arm tremor which is equals to movement variability also decreased with average 9.85% by using shoulder exoskeleton and maximum −19.5% in a certain position.Discussion: These experimental results show that our shoulder exoskeleton and its novel gravity compensation mechanism has enough clinical effectiveness for workers of underhead tasks, especially surgeons who conduct MIS. It reduced deltoid activations of wearers and also stabilized arm tremor which are directly related to performance of fine manipulative task, so that this research implies that shoulder exoskeletons are also need for underhead tasks and our shoulder exoskeleton has possibility to contribute to those utilities.

1 November 2014
Verified
Conference Paper
Closed access
DPDaegeun Park
Daegeun Park
HIHyunki In
Hyunki In
HLHaemin Lee
Haemin Lee
SLSangyeop Lee
Sangyeop Lee
IKInwook Koo
Inwook Koo
KCkyujin Cho
kyujin Cho
To assist the walk of the physically weak people is important to increase their quality of life because it can expand their activity area. We present a soft wearable knee extensor, called Knee Tendon-suit, which assist the knee extension during climbing stairs. To achieve our goal, we used the tendon-driven mechanism for transmitting the actuation force and the anchor structure for transmitting the actuation force to the body. Measuring Electromyography (EMG) at the femoral muscles and the tension at the anchor, we verified performance of the Knee Tendon-suit as the first preliminary result.

16 August 2022 in Frontiers in Physiology
Verified
Journal Article
Open access
HCHo Seon Choi
Ho Seon Choi
HIHyunki In
Hyunki In
Sustained shoulder abduction, which results from an inappropriate worktable height or tool shape and long task hours, leads to an accumulation of muscle fatigue and subsequent work-related injuries in workers. It can be alleviated by controlling the table height or ergonomic tool design, but workers who are doing some types of work that require a discomfortable posture, such as minimally invasive surgery, cannot avoid these situations. Loads to the shoulder joint or muscles result in several problems, such as muscle fatigue, deterioration of proprioception or changing movement strategies of the central nervous system, and these are critical to work that requires a high accuracy of the upper extremities. Therefore, in this paper, we designed and conducted an experiment with human participants to discuss how an inappropriate height of the work-table affects the task performance of workers who are performing a fine manipulative task that requires high accuracy of the end point. We developed an apparatus that can control the height and has four touch screens to evaluate the end-point accuracy with two different heights. Eighteen adults (9 women and 9 men) participated in the experiments, and the electromyography of their shoulder muscles, their movement stability, and task performance were measured for the analysis. We found that inappropriate height of a table brings about muscle fatigue, and time elapsed for conducting tasks accelerated the phenomenon. Task performance deteriorated according to increased fatigue, and improved movement stability is not enough to compensate for these situations.

28 March 2024 in IEEE Access
Verified
Journal Article
Open access
MLMyungjoong Lee
Myungjoong Lee
SKSeung-Won Kim
Seung-Won Kim
HIHyunki In
Hyunki In
Tactile maps are crucial for orientation and mobility (O&M) training for visually impaired people (VIP) to gain spatial knowledge of their surroundings. However, existing tactile maps are limited in their ability to facilitate actively generating information, modifying, and sharing by VIP individuals, making it challenging for them and O&M specialists to create and customize maps independently. To address this issue, we propose Archi-TangiBlock (ATB), an accessible computer-aided design (CAD) tool for VIP. ATB comprises a modular block-based tangible user interface that modularizes architectural landmarks, a panel for plugging in block modules, and a computer interface. Visually impaired users can use ATB to create a 3D CAD model by constructing a space with the blocks, enabling active learning. We evaluated ATB with visually impaired participants, and our results demonstrate that ATB enables visually impaired users to easily build maps, achieving a remarkably low error rate of 1.2%, and to gain an understanding of the overall spatial layout at a rate twice as fast as compared to conventional tactile maps.