Poomin Park

Poomin Park

Auto-generated profile, based on publicly available information

Poomin Park

Advanced Aeroengine Research Team, Korea Aerospace Research Institute, Daejeon 34133, Republic of Korea

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

3 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
SLSangyoon Lee
Sangyoon Lee
SJSangook Jun
Sangook Jun
JHJae-Sung Huh
Jae-Sung Huh
PPPoomin Park
Poomin Park
BLByeung Jun Lim
Byeung Jun Lim
The plate-fin heat exchanger was designed for the liquid cooling thermal management system of the hybrid electric propulsion system for an electric vertical take-off and landing (eVTOL) vehicle. The offset-strip fin design was applied, and the performance of the heat exchanger was evaluated, particularly with respect to the inclination of the airflow entering the heat exchanger. The estimated performance during the design phase matched well with the experimental results. The inclination of the heat exchanger had a minimal effect on thermal performance, with a slight increase in performance as the inclination increased. However, the pressure difference along the airflow was affected, likely increasing as the inclination increased. The sensitivity of various parameters on coolant temperature was also investigated. The air inlet temperature had a significant effect on coolant temperature, followed by the coolant flow rate. Therefore, when designing the thermal management system, careful consideration should be given to the ambient air temperature and coolant flow rate.

4 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
SJSangook Jun
Sangook Jun
SLSangyoon Lee
Sangyoon Lee
JHJae-Sung Huh
Jae-Sung Huh
PPPoo Min Park
Poo Min Park
BLByeung Jun Lim
Byeung Jun Lim
This study presents a hybrid CFD–ε–NTU–neural network framework for evaluating the thermal performance of compact heat exchangers installed in confined nacelle environments under severe space and weight constraints. Airflow was simulated using steady Reynolds-Averaged Navier–Stokes (RANS) equations with the shear stress transport (SST) k–ω turbulence model, while heat-exchanger performance was evaluated using the effectiveness–number of transfer units (ε–NTU) method. To provide a continuous functional interface between the analytical model and the CFD solver, a neural network was employed as a representation of ε–NTU-based thermal performance. The proposed framework was validated against wind tunnel experiments, showing good agreement with measured data, with a maximum deviation of approximately 2.2 °C in coolant outlet temperature. Using the validated framework, a multi-objective redesign of a compact heat exchanger was performed under practical installation constraints. The selected design achieved a 28.4% reduction in heat exchanger mass while maintaining cooling performance comparable to the baseline design. Installation performance was evaluated numerically in a modified nacelle configuration, where the redesigned heat exchanger increased the air mass flow rate by approximately 13% under identical fan operating conditions because of its reduced air-side flow resistance. The proposed framework provides a practical and efficient approach for system-level design and installation analysis of compact heat exchangers for aircraft thermal management systems.