In the quest to increase the share of renewable and residual energy sources in our energy system, and to reduce its greenhouse gas emissions, district heating networks and seasonal thermal energy storage have the potential to play a key role. Different studies prove the techno-economic potential of these technologies but, due to the added complexity, it is challenging to design and control such systems. This paper describes an integrated optimal design and control algorithm, which is applied to the design of a district heating network with solar thermal collectors, seasonal thermal energy storage and excess heat injection. The focus is mostly on the choice of the size and location of these technologies and less on the network layout optimisation. The algorithm uses a two-layer program, namely with a design optimisation layer implemented as a genetic algorithm and an optimal control evaluation layer implemented using the Python optimal control problem toolbox called modesto. This optimisation strategy is applied to the fictional district energy system case of the city of Genk in Belgium. We show that this algorithm can find optimal designs with respect to multiple objective functions and that even in the cheaper, less renewable solutions, seasonal thermal energy storage systems are installed in large quantities.
Network flexibility is the use of the thermal capacity of water that is contained in the district heating network pipes to store energy and shift the heat load in time. Through optimal control, this network flexibility can aid in applications such as peak shaving and operational heat pump optimisation. Yet, optimal control requires perfect predictions and complete knowledge of the system characteristics. In reality, this is not the case and uncertainties exist. To obtain insight into the importance of these uncertainties, this paper studies the influence of imperfect knowledge of building parameters on the optimal network flexibility activation and its performance. It is found that for the optimisation of heat pump operation, building parameter uncertainties do not present large risks. For peak shaving, a more robust result can be achieved by activating more network flexibility than may be required.
With the increasing integration of multiple energy carriers in district energy systems, an accurate simulation of the district energy demand becomes more crucial. To reduce the required computational power, the district energy demand is often quantified through a limited set of archetype buildings, representing the whole district. As the temporal behaviour is important to assess district energy systems, stochastic occupant models should be included in the simulation. However, obtaining representative set-point temperature profiles for archetype buildings is not straightforward, as all buildings respond differently to their demanded set-point temperature due to their thermal inertia. Hence, this paper proposes and compares three techniques to obtain the representative occupant behaviour for the archetype building, by focussing on 847 single-family dwellings. Including a smart occupant aggregation method allows to decrease the percentage error in annual energy demand for space heating between the full and the archetype simulation from around 7.5% to around 2%, depending on the building model and evaluation method.