George T. Gillies

George T. Gillies

Auto-generated profile, based on publicly available information

George T. Gillies

Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA, USA

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2021 in Journal of Modern Optics
Verified
Journal Article
Open access
GSGianfranco Spavieri
Gianfranco Spavieri
GGGeorge T. Gillies
George T. Gillies
EHEspen Haug
Espen Haug
We thoroughly examine the role of absolute and relative simultaneity in the interpretation of the Sagnac effect, using an approach that allows for determining the local speed along the light path. If the local speed of light is assumed to be c over the whole closed contour, there is no agreement with the observed result. There is agreement if the local speed is c along an open section of the contour only. Thus a rigorous and coherent interpretation of the Sagnac effect favours absolute over relative simultaneity. The implications for the Lorentz transformations and synchronization by means of the Global Positioning System are considered.

1 June 2018 in Journal of Pain Research
Verified
Journal Article
Open access
PDF file
CRChandan G Reddy
Chandan G Reddy
JMJohn W Miller
John W Miller
KAKingsley Abode-Iyamah
Kingsley Abode-Iyamah
SSSina Safayi
Sina Safayi
SWSaul Wilson
Saul Wilson
TBTimothy J Brennan
Timothy J Brennan
Background: It is becoming increasingly important to understand the mechanisms of spinal cord stimulation (SCS) in alleviating neuropathic pain as novel stimulation paradigms arise. Purpose: Additionally, the small anatomic scale of current SCS animal models is a barrier to more translational research. Methods: Using chronic constriction injury (CCI) of the common peroneal nerve (CPN) in sheep (ovine), we have created a chronic model of neuropathic pain that avoids motor deficits present in prior large animal models. This large animal model has allowed us to implant clinical grade SCS hardware, which enables both acute and chronic testing using von Frey filament thresholds and gait analysis. Furthermore, the larger anatomic scale of the sheep allows for simultaneous single-unit recordings from the dorsal horn and SCS with minimal electrical artifact. Results: Detectable tactile hypersensitivity occurred 21 days after nerve injury, with preliminary indications that chronic SCS may reverse it in the painful limb. Gait analysis revealed no hoof drop in the CCI model. Single neurons were identified and discriminated in the dorsal horn, and their activity was modulated via SCS. Unlike previous large animal models that employed a complete transection of the nerve, no motor deficit was observed in the sheep with CCI. Conclusion: To our knowledge, this is the first reported large animal model of chronic neuropathic pain which facilitates the study of both acute and chronic SCS using complementary behavioral and electrophysiologic measures. As demonstrated by our successful establishment of these techniques, an ovine model of neuropathic pain is suitable for testing the mechanisms of SCS.

17 September 2004 in Metrologia
Verified
Journal Article
Closed access
GSGianfranco Spavieri
Gianfranco Spavieri
GGG T Gillies
G T Gillies
MRM Rodriguez
M Rodriguez

31 October 2018 in Journal of Investigative Surgery
Verified
Journal Article
Closed access
SWS. Wilson
S. Wilson
SNS. J. Nagel
S. J. Nagel
LFL. A. Frizon
L. A. Frizon
DFD. C. Fredericks
D. C. Fredericks
NDN. A. DeVries-Watson
N. A. DeVries-Watson
MHM. A. Howard
M. A. Howard
Introduction: Translating basic science research into a safe and effective therapy for spinal cord injury (SCI) requires suitable large animal models for testing both implantable devices and biologic approaches to better approximate human anatomy and function. Hemisection lesions, routinely used for investigational purposes in small animals, are less frequently described in large animals that might be appropriate for translational studies. Size constraints of small animals (mice and rats) limits the predictability of the findings when scaled up. Our goal is to review the status of hemisection SCI in large animals across species and time to prepare for the testing of a novel intradural spinal cord stimulation device for control of spasticity in an ovine model. Methods and Results: We surveyed the literature on hemisection in quadrupeds and nonhuman primates, and catalogued the species, protocols and outcomes of the experimental work in this field. Feline, lapine, canine, simian, porcine, ovine and bovine models were the primary focal points. There is a consistent body of literature reporting use of the hemisection approach in large animals, but with differences in surgical technique depending on the goals and nature of the individual studies. While the injuries are not always consistent, the experimental variability is generally lower than that of the contusion-based approach. In general, as the body size of the animal increases, animal care requirements and the associated costs follow. In most cases, this is inversely correlated with the number of animals used in hemisection models. Conclusions: The hemisection approach to modeling SCI is straightforward compared with other methods such as the contusive impact and enables the transection of isolated ascending and descending tracts and segment specific cell bodies. This has certain advantages in models investigating post-injury axonal regrowth. However, this approach is not generally in line with the patho-physiologies encountered in SCI patients. Even so, the ability to achieve more control over the level of injury makes it a useful adjunct to contusive and ischemic approaches, and suggests a useful role in future translational studies.

19 January 2016 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
SSS. Safayi
S. Safayi
JMJ. W. Miller
J. W. Miller
SWS. Wilson
S. Wilson
SSS. K. Shivapour
S. K. Shivapour
TOT. F. Oelfke
T. F. Oelfke
MIM. A. Howard Iii
M. A. Howard Iii
Our laboratories are developing treadmill-based gait analysis employing sheep to investigate potential efficacy of intra-dural spinal cord stimulation in the treatment of spinal cord injury and neuropathic pain. As part of efforts to establish the performance characteristics of the experimental arrangement, this study measured the treadmill speed via a tachometer, video belt-marker timing and ambulation-rate observations of the sheep. The data reveal a 0.1–0.3% residual drift in the baseline (unloaded) treadmill speed which increases with loading, but all three approaches agree on final speed to within 1.7%, at belt speeds of ≈4 km/h. Using the tachometer as the standard, the estimated upper limit on uncertainty in the video belt-marker approach is ± 0.18 km h−1 and the measured uncertainty is ± 0.15 km h−1. Employment of the latter method in determining timing differences between contralateral hoof strikes by the sheep suggests its utility in assessing severity of SCI and responses to therapeutic interventions.

15 August 2012 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
SSSuk-Heung Song
Suk-Heung Song
GGGeorge T. Gillies
George T. Gillies
MHMatthew A. Howard
Matthew A. Howard
BKBrian Kuhnley
Brian Kuhnley
MUMarcel Utz
Marcel Utz