Bambang Ariantara

Bambang Ariantara

Auto-generated profile, based on publicly available information

Bambang Ariantara

Applied Heat Transfer Research Group, Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus Baru-Depok, Jawa Barat, 16424

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
NPNandy Putra
Nandy Putra
BABambang Ariantara
Bambang Ariantara
RPRangga Aji Pamungkas
Rangga Aji Pamungkas

1 November 2017 in Applied Thermal Engineering
Verified
Journal Article
Closed access
NPNandy Putra
Nandy Putra
BABambang Ariantara
Bambang Ariantara

24 January 2018 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
BABambang Ariantara
Bambang Ariantara
NPNandy Putra
Nandy Putra
SSSugeng Supriadi
Sugeng Supriadi
Loop heat pipes (LHPs) with Lotus-Type Porous Copper (LTP Copper) capillary wick are expected to be applied to battery thermal management systems for safe operation at high performance with a long service life. Sintered LTP Copper is a high permeability porous metal with an excellent capillary pumping characteristic. The objective of this work is to determine the performance of the battery thermal management system using LHP with sintered LTP Copper capillary wick experimentally. The experiment used two battery simulators made of aluminum. The heat generation of the battery was simulated using cartridge heaters. The LHP was made of 10 m OD copper tube, and the sintered LTP Copper capillary wick was placed in the liquid line. Water was used as working fluid with filling ratio of 50%. The evaporator section of the LHP was inserted between the battery simulators surfaces. A thermostatic bath was used to regulate the condenser cooling fluid temperature. K-type 0.3 mm thermocouples were used for temperature measurement, and a digital power meter was used to measure the electric power. Experiments were conducted with various heating power with the condenser cooling fluid temperature was kept at 28°C. At a heat generation of 20 W, the LHP was capable of maintaining the battery surface temperature below 50°C. At a heat generation of 40 W, the utilization of LHP with LTP Copper can reduce the average battery simulator surface temperature from 93°C to 65°C.

26 November 2018 in E3S Web of Conferences
Verified
Conference Paper
Open access
MAMuhammad Amin
Muhammad Amin
BABambang Ariantara
Bambang Ariantara
NPNandy Putra
Nandy Putra
ASAdjie Fahrizal Sandi
Adjie Fahrizal Sandi
NANasruddin A. Abdullah
Nasruddin A. Abdullah
The performance of an electric vehicle depends on the battery used. While, in the operation of an electric vehicle, batteries experience a quick heating especially at the beginning of charging and could cause a fire. Therefore, the solution could be proposed is by employing heat pipe and Phase Change Material (PCM) for cooling of battery. The heat pipe serves to transfer the battery’s heat energy. In other hands, PCM functions as a heat sink when the battery runs, so its performance will stable and extend the lifespan. This study aimed to evaluate the performance of electric vehicle batteries at a temperature of 50°C using the combination of heat pipe and PCM. The ‘L’ type of heat pipe and beeswax PCM were assembled as cooling device. In addition, a battery simulator was employed as a test instrument by varying the heat load of 20, 30, 40, and 50 W. The experiments were successfully conducted, and the results showed that the addition of heat pipe and PCM could keep the surface temperature of battery below 50°C, at heat load of 20 - 50 W. Heat pipe and PCM for battery’s cooling system, can reduce the battery surface temperature significantly and can be proposed as an alternative system for cooling battery.

26 November 2018
Verified
Conference Paper
Open access
NANurhalimah Aprianingsih
Nurhalimah Aprianingsih
AWAdi Winarta
Adi Winarta
BABambang Ariantara
Bambang Ariantara
NPNandy Putra
Nandy Putra
Heat generated in an electric motor can increase the operating temperature. The excessive operating temperature will reduce the electric motor performance and shorten the service life. An appropriate thermal management system is required to reduce the electric motor operating temperature. The objective of this study is to determine the thermal performance of pulsating heat pipes which applied to the electric motor thermal management system. A prototype of electric motor thermal management system was made from an induction motor with a cartridge heater instead of a heat-generating rotor and stator. Six pieces of pulsating heat pipe were mounted using hexagonal heat pipe holder which placed inside the electric motor housing. The pulsating heat pipes are made of a copper capillary tube using acetone as working fluid with a filling ratio of 0.5. The electric power input was varied from 30 W to 150 W. The use of pulsating heat pipes can reduce the electric motor surface temperature by 55.3°C with the minimum thermal resistance of 0.151°C/W.

1 April 2019 in Journal of Energy Storage
Verified
Journal Article
Closed access
NPNandy Putra
Nandy Putra
IHImansyah Ibnu Hakim
Imansyah Ibnu Hakim
FEFadel Prawira Erwin
Fadel Prawira Erwin
NANasruddin A. Abdullah
Nasruddin A. Abdullah
BABambang Ariantara
Bambang Ariantara
EKEny Kusrini
Eny Kusrini