1 October 2018 in Physica Medica
JDJ. Domienik-Andrzejewska
+22
1 January 2011 in Radiology and Oncology
External photon beam modulation using compensators in order to achieve a desired dose distribution when brachytherapy treatment is followed by external beam radiation is a well-established technique. A compensator modulates the central part of the beam, and the dose beneath the thickest part of the compensator is delivered mostly by scattered, low energy photons. A two-dimensional detector with a good spatial resolution is needed for the verification of those beams. In this work, the influence of different types of detectors on the measured modulated dose distributions was examined. Dosimetric verification was performed using X-Omat V, Eastman Kodak radiographic films at different depths in a solid water phantom. The film measurements were compared with those made by ionization chambers. Photon beams were also modelled using EGSnrc Monte Carlo algorithm to explain the measured results. Monte Carlo calculated over-response of the film under the thickest part of the compensator was over 15%, which was confirmed by measurements. The magnitude of over-response could be associated with changes in the spectra of photon energy in the beam. The radiographic film can be used for the dosimetry of compensated high energy photon beams, with limitations in volumes where photon spectra are hardly degraded.
1 March 2013 in Medical Dosimetry
4 May 2018 in Radiation Protection Dosimetry
Quality Assurance program on using ionizing radiation is mandatory in all EU member states but this is still not implemented in most facilities in Croatia mostly because of a lack of medical physicists in diagnostic radiology. Since public health institutions in Croatia do not employ medical physicists in diagnostic radiology, collaboration between these institutions in west region of Croatia with Clinical Hospital Center Rijeka (CHC) was initiated during the year 2015. Physicists from CHC Rijeka performed periodical Quality Control (QC) tests and were included in optimization process. Results of QC tests during the period of 2 years showed a lot of improvements—equipment is maintained more frequently, some old units were replaced with new ones and all institutions acquired QC equipment so radiographers could perform daily and monthly QC tests. All these activities showed that medical physics support in radiology departments is necessary and can improve clinical practice.
1 September 2011 in Archives of Industrial Hygiene and Toxicology
Implementation of advanced radiation therapy techniques in clinical practice can greatly improve tumour control and normal tissue sparing. An important part of this implementation is quality control (QC) of every part of the radiotherapy process, as it helps to detect errors and provides instant remedy. This increases the probability of successful radiation treatment and ensures patient radiation safety. Every radiotherapy quality assurance (QA) programme is based on quality control of radiotherapy equipment. The aim of our survey was to review QC practices in a number of radiotherapy centres in Croatia. As a first step, we defined a set of tests to check different parameters of linear accelerators and simulators in these centres. The tests were defined and performed according to protocols developed at two university hospitals. Test results varied largely between the centres. This calls for harmonisation of QC protocols.