Iwona Gorczynska

Iwona Gorczynska

Auto-generated profile, based on publicly available information

Iwona Gorczynska

Nicolaus Copernicus Univ. (Poland)

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
BPBenjamin Potsaid
Benjamin Potsaid
IGIwona Gorczynska
Iwona Gorczynska
VSVivek J. Srinivasan
Vivek J. Srinivasan
YCYueli Chen
Yueli Chen
JJJames Jiang
James Jiang
JFJames G. Fujimoto
James G. Fujimoto
We demonstrate ultrahigh speed spectral/Fourier domain optical coherence tomography (OCT) using an ultrahigh speed CMOS line scan camera at rates of 70,000–312,500 axial scans per second. Several design configurations are characterized to illustrate trade-offs between acquisition speed, resolution, imaging range, sensitivity and sensitivity roll-off performance. Ultrahigh resolution OCT with 2.5–3.0 micron axial image resolution is demonstrated at ~100,000 axial scans per second. A high resolution spectrometer design improves sensitivity roll-off and imaging range performance, trading off imaging speed to 70,000 axial scans per second. Ultrahigh speed imaging at > 300,000 axial scans per second with standard image resolution is also demonstrated. Ophthalmic OCT imaging of the normal human retina is investigated. The high acquisition speeds enable dense raster scanning to acquire densely sampled volumetric three dimensional OCT (3D-OCT) data sets of the macula and optic disc with minimal motion artifacts. Imaging with ~8–9 micron axial resolution at 250,000 axial scans per second, a 512 × 512 × 400 voxel volumetric 3D-OCT data set can be acquired in only ~1.3 seconds. Orthogonal registration scans are used to register OCT raster scans and remove residual axial eye motion, resulting in 3D-OCT data sets which preserve retinal topography. Rapid repetitive imaging over small volumes can visualize small retinal features without motion induced distortions and enables volume registration to remove eye motion. Cone photoreceptors in some regions of the retina can be visualized without adaptive optics or active eye tracking. Rapid repetitive imaging of 3D volumes also provides dynamic volumetric information (4D-OCT) which is shown to enhance visualization of retinal capillaries and should enable functional imaging. Improvements in the speed and performance of 3D-OCT volumetric imaging promise to enable earlier diagnosis and improved monitoring of disease progression and response to therapy in ophthalmology, as well as have a wide range of research and clinical applications in other areas.

1 April 2008 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
VSVivek J. Srinivasan
Vivek J. Srinivasan
BMBryan K. Monson
Bryan K. Monson
MWMaciej Wojtkowski
Maciej Wojtkowski
RBRichard A. Bilonick
Richard A. Bilonick
IGIwona Gorczynska
Iwona Gorczynska
JFJames G. Fujimoto
James G. Fujimoto
Purpose. To visualize, quantitatively assess, and interpret outer retinal morphology by using high-speed, ultrahigh-resolution (UHR) OCT. methods. Retinal imaging was performed in the ophthalmic clinic in a cross-section of 43 normal subjects with a 3.5-μm, axial-resolution, high-speed, UHR OCT prototype instrument, using a radial scan pattern (24 images, 1500 axial scans). Outer retinal layers were automatically segmented and measured. High-definition imaging was performed with a 2.8-μm axial-resolution, high-speed, UHR OCT research prototype instrument, to visualize the finer features in the outer retina. results. Quantitative maps of outer retinal layers showed clear differences between the cone-dominated fovea and the rod-dominated parafovea and perifovea, indicating that photoreceptor morphology can explain the appearance of the outer retina in high-speed, UHR OCT images. Finer, scattering bands were visualized in the outer retina using high-definition imaging and were interpreted by comparison to known anatomy. conclusions. High-speed UHR OCT enables quantification of scattering layers in the outer retina. An interpretation of these features is presented and supported by quantitative measurements in normal subjects and comparison with known anatomy. The thick scattering region of the outer retina previously attributed to the retinal pigment epithelium (RPE) is shown to consist of distinct scattering bands corresponding to the photoreceptor outer segment tips, RPE, and Bruch’s membrane. These results may advance understanding of the outer retinal appearance in OCT images. The normative measurements may also aid in future investigations of outer retinal changes in age-related macular degeneration and other diseases.

1 September 2004 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
MWMacIej Wojtkowski
MacIej Wojtkowski
TBTomasz Bajraszewski
Tomasz Bajraszewski
IGIwona Gorczyńska
Iwona Gorczyńska
PTPiotr Targowski
Piotr Targowski
AKAndrzej Kowalczyk
Andrzej Kowalczyk
CRCzesław Radzewicz
Czesław Radzewicz

1 November 2008 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
VSVivek J. Srinivasan
Vivek J. Srinivasan
DADesmond C. Adler
Desmond C. Adler
YCYueli Chen
Yueli Chen
IGIwona Gorczynska
Iwona Gorczynska
RHRobert Huber
Robert Huber
JFJames G. Fujimoto
James G. Fujimoto
Purpose. To demonstrate ultrahigh-speed optical coherence tomography (OCT) imaging of the retina and optic nerve head at 249,000 axial scans per second and a wavelength of 1060 nm. To investigate methods for visualization of the retina, choroid, and optic nerve using high-density sampling enabled by improved imaging speed. methods. A swept-source OCT retinal imaging system operating at a speed of 249,000 axial scans per second was developed. Imaging of the retina, choroid, and optic nerve were performed. Display methods such as speckle reduction, slicing along arbitrary planes, en face visualization of reflectance from specific retinal layers, and image compounding were investigated. results. High-definition and three-dimensional (3D) imaging of the normal retina and optic nerve head were performed. Increased light penetration at 1060 nm enabled improved visualization of the choroid, lamina cribrosa, and sclera. OCT fundus images and 3D visualizations were generated with higher pixel density and less motion artifacts than standard spectral/Fourier domain OCT. En face images enabled visualization of the porous structure of the lamina cribrosa, nerve fiber layer, choroid, photoreceptors, RPE, and capillaries of the inner retina. conclusions. Ultrahigh-speed OCT imaging of the retina and optic nerve head at 249,000 axial scans per second is possible. The improvement of ∼5 to 10× in imaging speed over commercial spectral/Fourier domain OCT technology enables higher density raster scan protocols and improved performance of en face visualization methods. The combination of the longer wavelength and ultrahigh imaging speed enables excellent visualization of the choroid, sclera, and lamina cribrosa.

22 January 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
VSVivek J. Srinivasan
Vivek J. Srinivasan
SSSava Sakadžić
Sava Sakadžić
IGIwona Gorczynska
Iwona Gorczynska
SRSvetlana Ruvinskaya
Svetlana Ruvinskaya
WWWeicheng Wu
Weicheng Wu
DBDavid A. Boas
David A. Boas
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal monitoring of CBF with high resolution in rats and mice. Using three-dimensional Doppler Optical Coherence Tomography and cranial window preparations, we present methods and algorithms for regional CBF measurements in the rat cortex. Towards this end, we develop and validate a quantitative statistical model to describe the effect of static tissue on velocity sensitivity. This model is used to design scanning protocols and algorithms for sensitive 3D flow measurements and angiography of the cortex. We also introduce a method of absolute flow calculation that does not require explicit knowledge of vessel angles. We show that OCT estimates of absolute CBF values in rats agree with prior measures by autoradiography, suggesting that Doppler OCT can perform absolute flow measurements in animal models.

1 February 2010 in Retina
Verified
Journal Article
Open access
ASAlan C. Sull
Alan C. Sull
LVLaurel N. Vuong
Laurel N. Vuong
LPLori Lyn Price
Lori Lyn Price
VSVivek J. Srinivasan
Vivek J. Srinivasan
IGIwona Gorczynska
Iwona Gorczynska
JDJay S. Duker
Jay S. Duker
Purpose: The purpose of this study was to report normal macular thickness measurements and assess reproducibility of retinal thickness measurements acquired by a time-domain optical coherence tomography (OCT) (Stratus, Carl Zeiss Meditec, Inc., Dublin, CA) and three commercially available spectral/Fourier domain OCT instruments (Cirrus HD-OCT, Carl Zeiss Meditec, Inc.; RTVue-100, Optovue, Inc., Fremont, CA; 3D OCT-1000, Topcon, Inc., Paramus, NJ). Methods: Forty randomly selected eyes of 40 normal, healthy volunteers were imaged. Subjects were scanned twice during 1 visit and a subset of 25 was scanned again within 8 weeks. Retinal thickness measurements were automatically generated by OCT software and recorded after manual correction. Regression and Bland–Altman plots were used to compare agreement between instruments. Reproducibility was analyzed by using intraclass correlation coefficients, and incidence of artifacts was determined. Results: Macular thickness measurements were found to have high reproducibility across all instruments with intraclass correlation coefficients values ranging 84.8% to 94.9% for Stratus OCT, 92.6% to 97.3% for Cirrus Cube, 76.4% to 93.7% for RTVue MM5, 61.1% to 96.8% for MM6, 93.1% to 97.9% for 3D OCT-1000 radial, and 31.5% to 97.5% for 3D macular scans. Incidence of artifacts was higher in spectral/Fourier domain instruments, ranging from 28.75% to 53.16%, compared with 17.46% in Stratus OCT. No significant age or sex trends were found in the measurements. Conclusion: Commercial spectral/Fourier domain OCT instruments provide higher speed and axial resolution than the Stratus OCT, although they vary greatly in scanning protocols and are currently limited in their analysis functions. Further development of segmentation algorithms and quantitative features are needed to assist clinicians in objective use of these newer instruments to manage diseases.