Department of Anaesthesiology, West China Hospital, Sichuan University & The Research Units of West China, Chinese Academy of Medical Sciences, Chengdu, China
Auto-generated profile, based on publicly available information
Xiao Xiao
Department of Anaesthesiology, West China Hospital, Sichuan University & The Research Units of West China, Chinese Academy of Medical Sciences, Chengdu, China
Purpose: The study aimed to develop a motion capture system that can track, visualize, and analyze the entire performance of self-injection with the auto-injector. Methods: Each of nine healthy subjects and 29 rheumatoid arthritic (RA) patients with different degrees of hand disability performed two simulated injections into an injection pad while six degrees of freedom (DOF) motions of the auto-injector and the injection pad were captured. We quantitatively measured the performance of the injection by calculating needle displacement from the motion trajectories. The max, mean, and SD of needle displacement were analyzed. Assessments of device acceptance and usability were evaluated by a survey questionnaire and independent observations of compliance with the device instruction for use (IFU). Results: A total of 80 simulated injections were performed. Our results showed a similar level of performance among all the subjects with slightly larger, but not statistically significant, needle displacement in the RA group. In particular, no significant effects regarding previous experience in self-injection, grip method, pain in hand, and Cochin score in the RA group were found to have an impact on the mean needle displacement. Moreover, the analysis of needle displacement for different durations of injections indicated that most of the subjects reached their personal maximum displacement in 15 seconds and remained steady or exhibited a small amount of increase from 15 to 60 seconds. Device acceptance was high for most of the questions (ie, >4; >80%) based on a 0–5-point scale or percentage of acceptance. The overall compliance with the device IFU was high for the first injection (96.05%) and reached 98.02% for the second injection. Conclusion: We demonstrated the feasibility of tracking the motions of injection to measure the performance of simulated self-injection. The comparisons of needle displacement showed that even RA patients with severe hand disability could properly perform self-injection with this auto-injector at a similar level with the healthy subjects. Finally, the observed high device acceptance and compliance with device IFU suggest that the system is convenient and easy to use.
We contribute a new integrated system designed for high-quality 3D reconstructions. The system consists of a sparse set of commodity RGB-D cameras, which allows for fast and accurate scan of objects with multi-view inputs. We propose a robust and efficient tile-based streaming pipeline for geometry reconstruction with TSDF fusion which minimizes memory overhead and calculation cost. Our multi-grid warping method for texture optimization can address misalignments of both global structures and small details due to the errors in multi-camera registration, optical distortions and imprecise geometries. In addition, we apply a global color correction method to reduce color inconsistency among RGB images caused by variations of camera settings. Finally, we demonstrate the effectiveness of our proposed system with detailed experiments of multi-view datasets.
This paper provides a sample document for NIME 2021. It is based on previous NIME paper templates, which conform somewhat loosely to the formatting guidelines for ACM SIG Proceedings. The paper submitted to the NIME conference must be a PDF file produced by PubPub. Since PubPub accounts are not anonymous, papers will be reviewed elsewhere. Details are given in this template and also in the Call for Papers . Your abstract should preferably be between 100 and 200 words.