Siddharth Tripathi

Siddharth Tripathi

Auto-generated profile, based on publicly available information

Siddharth Tripathi

New Jersey Center for Engineered Particulates, New Jersey Institute of Technology, Newark, NJ 07102, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

29 August 2025 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
STSiddharth Tripathi
Siddharth Tripathi
AOAnna Owasit
Anna Owasit
EAElzar Adham
Elzar Adham
CKChristopher Kossor
Christopher Kossor
Rajesh N. DaveRajesh N. Dave
Rajesh N. Dave
As predicted by the multi-asperity particle contact model, powder cohesion can be significantly reduced through dry coating of silica using a high-intensity vibratory mixer (HIVM). To promote industry adoption of dry coating, industry-relevant devices, a low-intensity V-blender and a medium-intensity comil, were evaluated against HIVM as a benchmarking control. Since low/medium intensity devices could lead to less effective silica dispersion, the contact model was extended to account for silica agglomeration. Three model APIs, belonging to very cohesive and cohesive flow category, were coated with two silica types (A200 and R972P) for enhancing flow (flow function coefficient - FFC) and conditioned bulk density (CBD). The V-blender exhibited least improvements in FFC and CBD. Corresponding SEM images revealed poor silica dispersion and presence of large porous agglomerates on coated API surfaces. Comil, at one and five passes with different-sized screens, performed better than V-blender. While FFC and CBD improved, some silica agglomeration on API surfaces was evident. HIVM, due to well-dispersed silica coating, achieved the most significant, 2-3 category enhancements in FFC and CBD at higher intensities. These results, in line with the extended model predictions, indicated that whereas V-blender would be unsuitable for dry coating due to excessive silica agglomeration, comil with finer screens would be a promising continuous manufacturing option for enhancing fine powder flowability. Device equivalence analysis identified lower intensity HIVM operating conditions that could achieve performance comparable to best outcomes from V-blender or comil; potentially enabling HIVM as a surrogate material sparing screening device.

16 July 2025 in Separation and Purification Technology
Verified
Journal Article
Open access
YSYufeng Song
Yufeng Song
LFLixin Feng
Lixin Feng
WZWei Zhong
Wei Zhong
STSiddharth Tripathi
Siddharth Tripathi
PAPadmini K. Ananthoji
Padmini K. Ananthoji
KSKamalesh K. Sirkar
Kamalesh K. Sirkar

14 May 2025 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
STSiddharth Tripathi
Siddharth Tripathi
MEM. Sebastian Escotet-Espinoza
M. Sebastian Escotet-Espinoza
JTJames Tarabokija
James Tarabokija
GKGerard Klinzing
Gerard Klinzing
JDJames DiNunzio
James DiNunzio
Rajesh N. DaveRajesh N. Dave
Rajesh N. Dave
Dry coating fine pharmaceutical powders with nano-silica has been shown to enhance their bulk properties and their blend processability at lab-scale, potentially facilitating tablet manufacturing. This study critically investigates key aspects of dry coating from industrial applicability perspective: (1) evaluating the selection of silica amount based on the host particle surface area coverage (SAC) against the industry standard 1 wt% addition, (2) assessing the feasibility of continuous dry coating using a pilot-scale conical screen mill (comil-U10) compared to the lab-scale batch high-intensity vibratory mixer (HIVM), and (3) investigating downstream processing improvements from dry coating via feedability and tabletability studies. Results from six different pharmaceutical powders (d50 ∼ 3-35 μm) demonstrated that SAC-based silica wt.% selection outperformed 1 wt% silica for bulk properties enhancements. Multi-faceted characterization revealed that FFC was the most reliable amongst Hausner's ratio, compressibility, and permeability tests. Three selected materials (d50 ∼ 16-26 μm) for comil processing showed remarkable one-flow category improvement, though two finer materials fell short of the HIVM performance. The dry coated materials demonstrated superior feed rate stability, demonstrating reduced flow variability, attributed to enhanced flowability and lower compressibility. Tablets of formulations containing dry-coated API using either comil or HIVM outperformed formulations with blended silica at three drug loads, 10 %, 30 %, and 60 %, likely due to better silica dispersion. These outcomes demonstrate the benefits of potentially scalable comil-based dry coating to continuous manufacturing of tableting, potentially eliminating the need for granulation.

27 April 2026 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
AOAnna Owasit
Anna Owasit
STSiddharth Tripathi
Siddharth Tripathi
Rajesh N. DaveRajesh N. Dave
Rajesh N. Dave
Segregation behavior of binary blends of free-flowing powders was systematically investigated to develop a quantitative model for predicting segregation tendencies as a function of key particle properties. Binary blends, eight training and two testing, were prepared from seven materials, spanning a range of ratios of particle size, bulk density, and aspect ratios. A novel tape test sample preparation technique, developed to enhance the accuracy of blend uniformity measurements, reduce material usage, and minimize sampling errors, helps validate the use of a Near-Infrared (NIR) probe-based SPECTester to assess segregation intensity (SI) of those binary blends. Cumulative segregation area (CSA), defined as the integrated absolute deviation area between the cumulative concentration profile and the no-segregation baseline, was introduced as a novel measure of segregation that better captured the segregation tendency across a range of variables. A multi-variate power-law model, capturing the combined influence of these properties on segregation behavior, was developed. For the segregation intensity (SI)-based model, predictions closely matched experimental measurements for the training dataset (R2 ≈ 0.98) and maintained good accuracy for unseen test blends (R2 ≈ 0.85). When evaluated using CSA, the model exhibited strong generalization, achieving R2 = 0.92 for the training dataset and R2 = 0.96 for the test blends. Heatmap visualizations overlaid with experimental data confirmed that higher D50 × bulk density ratios increased segregation intensity, whereas larger ratios of aspect ratio mitigated segregation. Overall, a robust quantitative framework was established for understanding and predicting segregation in free-flowing powder systems, potentially enabling improved blend uniformity.

19 April 2026 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
STSiddharth Tripathi
Siddharth Tripathi
AOAnna Owasit
Anna Owasit
CKChristopher Kossor
Christopher Kossor
RBRoopal Bhat
Roopal Bhat
Rajesh N. DaveRajesh N. Dave
Rajesh N. Dave
The granular Bond number, estimated using Chen's multi-asperity particle adhesion model, has been shown as a basis for powder flowability prediction for both as-received and dry-coated powders. Here, the prediction model calibrated solely using as-received powders is tested by estimating the expected flowability enhancement after dry coating with two different nano-silicas. Prediction accuracy for 9 APIs and 18 excipients is compared for three characteristic particle size parameters for the Bond number; median particle size (d50), Sauter mean diameter (d3,2), and the size class-dependent (SCD) metric utilizing entire particle size distribution (PSD). A new sigmoid-function based flowability prediction model is proposed and fitted for as-received powders. Both d3,2 and SCD lead to better predictive accuracy with narrower prediction intervals as compared to d50, suggesting d3,2 captures the same surface-area-dependent PSD effects as SCD without added computational burden. The model could accurately predict flow category for all but one as-received powder. The model calibrated through as-received uncoated powders can predict enhancement of one to three flow categories for most dry coated powders with high accuracy. Notable exceptions are materials with SSA above ∼2 m2/g whose experimental SSA deviates significantly from PSD-estimated theoretical SSA (high ΔSSA), indicating surface roughness or adherent debris that restricts dry coating effectiveness. Materials with high SSA but low ΔSSA, where high surface area is simply a consequence of fine particle size, respond well to dry coating as predicted. In summary, the proposed unifying model can be calibrated using small samples of as-received powders to estimate expected flowability improvements after dry coating and, importantly, to identify dry coated powders likely to underperform.