Yinglun Tan

Yinglun Tan

Auto-generated profile, based on publicly available information

Yinglun Tan

School of Artificial Intelligence and Data Science, Hebei University of Technology, Hong Qiao, Tianjin, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2021 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
YTYinglun Tan
Yinglun Tan
ZFZhuoxin Fu
Zhuoxin Fu
LDLunhui Duan
Lunhui Duan
RCRui Cui
Rui Cui
MWMengkun Wu
Mengkun Wu
HSHao Sun
Hao Sun

27 December 2021
Verified
Conference Paper
Closed access
LDLunhui Duan
Lunhui Duan
HSHao Sun
Hao Sun
BXBokai Xuan
Bokai Xuan
YTYinglun Tan
Yinglun Tan
RCRui Cui
Rui Cui
MWMengkun Wu
Mengkun Wu
ArUco is an efficient and convenient method to estimate pose of the robot or the object by detecting corner points. However, ArUco cannot be used in some cases due to its lack of detection stability and insufficient accuracy. In this paper, an improved monocular 6D pose estimation method based on the spatial icosahedron marked by ArUco is proposed. By identifying the marked points on the surface of the icosahedron in the image, matching the 3D points in the database and solving with the Perspective-n-points(PnP) method, the accurate 6D pose estimation of the robot can be obtained. Compared with the original ArUco, the method proposed in this paper can cope with larger pose changes, provide higher accuracy, and improve the detection stability, while the time complexity is not significantly increased. In most cases, the method proposed in this paper can achieve translation accuracy of sub-millimeter level and rotation accuracy of less than 1°. Besides, it realized the ±180° large-scale rotation detection of three axes, and the real-time indicators is also satisfied.

10 January 2022 in Journal of Digital Imaging
Verified
Journal Article
Open access
PDF file
LDLunhui Duan
Lunhui Duan
HSHao Sun
Hao Sun
DLDelong Liu
Delong Liu
YTYinglun Tan
Yinglun Tan
YGYue Guo
Yue Guo
XDXiaojing Ding
Xiaojing Ding
Clinically, Taylor spatial frame (TSF) is usually used to correct femoral deformity. The first step in correction is to analyze skeletal deformities and measure the center of rotation of angulation (CORA). Since the above work needs to be done manually, the doctor’s workload is heavy. Therefore, an automatic femoral deformity analysis system was proposed. Firstly, the Hough forest and constrained local models were trained on the femur image set. Then, the position and size of the femur in the X-ray image were detected by the trained Hough forest. Furthermore, the position and size were served as the initial values of the trained constrained local models to fit the femoral contour. Finally, the anatomical axis line of the proximal femur and the anatomical axis line of the distal femur could be drawn according to the fitting results. According to these lines, CORA can be found. Compared with manual measurement by doctors, the average error of the hip joint orientation line was 1.7°, the standard deviation was 1.75, the average error of the anatomic axis line of the proximal femur was 2.9°, and the standard deviation was 3.57. The automatic femoral deformity analysis system meets the accuracy requirements of orthopedics and can significantly reduce the workload of doctors.