To evaluate the quantitative characteristics of the radial peripapillary capillary (RPC) network in glaucoma, glaucoma suspect, and normal eyes using speckle variance optical coherence tomography angiography (OCT-A). To determine correlations between RPC density, nerve fiber layer (NFL) thickness, and visual field indices. Cross-sectional study. OCT-A images of RPCs were acquired at a single institution using a custom-built 1060 nm system from 3 groups: unilateral glaucoma (10 eyes from 5 subjects), glaucoma suspects (6 eyes from 3 subjects), and normal control eyes (16 eyes from 9 normal subjects). Peripapillary NFL thickness measurements were determined using spectral-domain optical coherence tomography. Glaucoma and glaucoma suspects also underwent automated 30-2 Humphrey visual field analysis. Manual tracing techniques were used to quantify RPC density in the OCT-A images. Data were analyzed using a linear mixed model with 1 fixed-effect covariate. Correlations between main outcome measures (RPC density, NFL thickness, and visual field index) were determined. Mean age was not significantly different between the 3 groups (P = .25). The density of RPCs was significantly lower in glaucomatous eyes compared with matched-peripapillary regions in the fellow eye, glaucoma suspect group, and normal group (all P < .001). RPC density was strongly correlated with NFL thickness (P < .001) and visual field index (P < .001). Significant reductions in RPC density were correlated with sites of NFL decrease and visual field loss in glaucoma. Speckle variance OCT-A allows visualization and quantification of RPCs and may therefore be a useful tool for indirectly quantifying and monitoring retinal ganglion cell axonal injury in glaucoma.
28 January 2020 in Translational Vision Science & Technology
Purpose: To evaluate the role of ensemble learning techniques with deep learning in classifying diabetic retinopathy (DR) in optical coherence tomography angiography (OCTA) images and their corresponding co-registered structural images. Methods: A total of 463 volumes from 380 eyes were acquired using the 3 × 3-mm OCTA protocol on the Zeiss Plex Elite system. Enface images of the superficial and deep capillary plexus were exported from both the optical coherence tomography and OCTA data. Component neural networks were constructed using single data-types and fine-tuned using VGG19, ResNet50, and DenseNet architectures pretrained on ImageNet weights. These networks were then ensembled using majority soft voting and stacking techniques. Results were compared with a classifier using manually engineered features. Class activation maps (CAMs) were created using the original CAM algorithm and Grad-CAM. Results: The networks trained with the VGG19 architecture outperformed the networks trained on deeper architectures. Ensemble networks constructed using the four fine-tuned VGG19 architectures achieved accuracies of 0.92 and 0.90 for the majority soft voting and stacking methods respectively. Both ensemble methods outperformed the highest single data-type network and the network trained on hand-crafted features. Grad-CAM was shown to more accurately highlight areas of disease. Conclusions: Ensemble learning increases the predictive accuracy of CNNs for classifying referable DR on OCTA datasets. Translational Relevance: Because the diagnostic accuracy of OCTA images is shown to be greater than the manually extracted features currently used in the literature, the proposed methods may be beneficial toward developing clinically valuable solutions for DR diagnoses.
To evaluate the performance of a federated learning framework for deep neural network-based retinal microvasculature segmentation and referable diabetic retinopathy (RDR) classification using OCT and OCT angiography (OCTA). Retrospective analysis of clinical OCT and OCTA scans of control participants and patients with diabetes. The 153 OCTA en face images used for microvasculature segmentation were acquired from 4 OCT instruments with fields of view ranging from 2 × 2-mm to 6 × 6-mm. The 700 eyes used for RDR classification consisted of OCTA en face images and structural OCT projections acquired from 2 commercial OCT systems. OCT angiography images used for microvasculature segmentation were delineated manually and verified by retina experts. Diabetic retinopathy (DR) severity was evaluated by retinal specialists and was condensed into 2 classes: non-RDR and RDR. The federated learning configuration was demonstrated via simulation using 4 clients for microvasculature segmentation and was compared with other collaborative training methods. Subsequently, federated learning was applied over multiple institutions for RDR classification and was compared with models trained and tested on data from the same institution (internal models) and different institutions (external models). For microvasculature segmentation, we measured the accuracy and Dice similarity coefficient (DSC). For severity classification, we measured accuracy, area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve, balanced accuracy, F1 score, sensitivity, and specificity. For both applications, federated learning achieved similar performance as internal models. Specifically, for microvasculature segmentation, the federated learning model achieved similar performance (mean DSC across all test sets, 0.793) as models trained on a fully centralized dataset (mean DSC, 0.807). For RDR classification, federated learning achieved a mean AUROC of 0.954 and 0.960; the internal models attained a mean AUROC of 0.956 and 0.973. Similar results are reflected in the other calculated evaluation metrics. Federated learning showed similar results to traditional deep learning in both applications of segmentation and classification, while maintaining data privacy. Evaluation metrics highlight the potential of collaborative learning for increasing domain diversity and the generalizability of models used for the classification of OCT data.
We present wavefront sensorless adaptive optics (WSAO) Fourier domain optical coherence tomography (FD-OCT) for in vivo small animal retinal imaging. WSAO is attractive especially for mouse retinal imaging because it simplifies optical design and eliminates the need for wavefront sensing, which is difficult in the small animal eye. GPU accelerated processing of the OCT data permitted real-time extraction of image quality metrics (intensity) for arbitrarily selected retinal layers to be optimized. Modal control of a commercially available segmented deformable mirror (IrisAO Inc.) provided rapid convergence using a sequential search algorithm. Image quality improvements with WSAO OCT are presented for both pigmented and albino mouse retinal data, acquired in vivo.
Cellular-resolution in vivo fluorescence imaging is a valuable tool for longitudinal studies of retinal function in vision research. Wavefront sensorless adaptive optics (WSAO) is a developing technology that enables high-resolution imaging of the mouse retina. In place of the conventional method of using a Shack-Hartmann wavefront sensor to measure the aberrations directly, WSAO uses an image quality metric and a search algorithm to drive the shape of the adaptive element (i.e. deformable mirror). WSAO is a robust approach to AO and it is compatible with a compact, low-cost lens-based system. In this report, we demonstrated a hill-climbing algorithm for WSAO with a variable focus lens and deformable mirror for non-invasive in vivo imaging of EGFP (enhanced green fluorescent protein) labelled ganglion cells and microglia cells in the mouse retina.
Small animal models of retinal diseases are important to vision research, and noninvasive high resolution in vivo rodent retinal imaging is becoming an increasingly important tool used in this field. We present a custom Fourier domain optical coherence tomography (FD-OCT) instrument for high resolution imaging of mouse retina. In order to overcome aberrations in the mouse eye, we incorporated a commercial adaptive optics system into the sample arm of the refractive FD-OCT system. Additionally, a commercially available refraction canceling lens was used to reduce lower order aberrations and specular back-reflection from the cornea. Performance of the adaptive optics (AO) system for correcting residual wavefront aberration in the mice eyes is presented. Results of AO FD-OCT images of mouse retina acquired in vivo with and without AO correction are shown as well.