2 March 2023 in Resilient Cities and Structures
16 January 2023 in Earthquake Engineering & Structural Dynamics
Understanding the effects of repair on reinforced concrete (RC) structures is critical to evaluating their performance in future earthquakes. In this research, a system‐level approach is taken by repairing a previously damaged ¼ scale 4‐storey RC structure and subjecting it to a series of dynamic excitations via shake table testing. The repair was undertaken using common construction materials with the primary motivation of restoring original performance. The performance of the repaired structure was compared to that of the original structure prior to repairs. It was found that overall initial stiffness of the structure was recovered to 66% of the original initial stiffness and was generally higher in floors where more intensive repair works were undertaken. Damping capacity was quantified via equivalent viscous damping ratio using three different methods. Regardless of the calculation method, the damping capacity recovery was around 80% for low‐moderate drifts and 100% for high drifts. While collapse was not induced in the structure, drift ratio demands of over 5% could be achieved both before and after repairs, suggesting a full practical recovery of deformation capacity. Structural strength of the repaired structure was found to be 17% higher than that of the original structure.
30 July 2021 in Journal of Structural and Construction Engineering (Transactions of AIJ)
After an earthquake, it is important to evaluate the residual seismic capacity of damaged buildings in order to determine the necessity of repair and retrofit and to make an efficient recovery plan. In this regard, a Japanese guideline developed by the Japan Building Disaster Prevention Association (JBPDA) “Standard for Post-earthquake Damage Level Classification of Buildings 1) ” is currently in use in Japan to estimate the residual seismic capacity of structures based on an index named R. The R-index represents the ratio of seismic capacity before and after the earthquake. The R-index calculation is intended to be a simple seismic evaluation method that does not require complicated analysis. However, this simplified method is based on the assumption that the ultimate deformation capacity of all members is the same; thus, it is not practical for assessing dual systems, such as reinforced concrete (RC) buildings containing both moment resisting frames and walls. The main objective of this study is to propose a new evaluation method to determine the R-index for buildings of mixed structure types. The proposed method uses two factors: (i) explicit consideration of different deformation capacities of structural members, θu, and (ii) a seismic capacity reduction factor, ηW 7) which considers the hysteretic energy absorption reduction of each structural member based on the observed level of damage. The available JBDPA method and the proposed method are assessed using results obtained from a shake-table test of an RC building. Firstly, the proposed simplified calculation method is explained in detail. Next, the results from a 1/4 scale 4-story RC frame-wall shaking table test are summarized (conducted jointly by Tohoku University and Obayashi Corporation). The 4-story specimen was designed with different frame and wall strength contributions in the longitudinal and transverse directions to investigate the impact that this has on the evaluation of residual seismic capacity ratio. The RC walls were designed to fail first, followed by the formation of a ‘strong column-weak beam’ frame-sway mechanism. Finally, each simplified calculation method (the proposed method and the existing Japanese guideline method) are applied to the building. The accuracy of the resulting R-index is verified by comparing with the results of the experiment. In general, the results showed that both methods identified the correct tendency of residual seismic capacity observed from the experimental values. In the longitudinal X-direction, though the proposed method was closer the experimental residual capacity results, both methods were considerably lower than the experimental data as the structure did not shown strength degradation despite extensive wall damage. In the transverse Y-direction the proposed method resulted in a higher residual seismic capacity ratio compared with experimental results. The reason for this being that a flexural failure mode was assumed for the wall in the calculation, whereas a less ductile shear failure was observed in the experiment.
1 December 2025 in Journal of Structural Engineering