Raudel Avila

Raudel Avila

Auto-generated profile, based on publicly available information

Raudel Avila

Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2025 in Science Advances
Verified
Journal Article
Open access
JKJunyeop Kim
Junyeop Kim
JYJeongmin Yoo
Jeongmin Yoo
HSHantae Seo
Hantae Seo
RARaudel Avila
Raudel Avila
GCGooyoon Chung
Gooyoon Chung
YPYoonseok Park
Yoonseok Park
The development of stable and multifunctional monitoring or actuating systems for implantable biomedical devices necessitates a high-capacity power supply. By using the oscillation of a magnetic field, energy can be transmitted through various media such as skin, fat, liquids, metals, and fabrics. We demonstrate a magnetically actuated implantable triboelectric generator that can effectively transfer energy independently of the surrounding media. The oscillation of the magnetic field enables contact of elastomeric magnets with the top and bottom electrodes of the generator, generating a path for electrical energy through contact electrification. The performance of the magnetically actuated triboelectric generator exhibits high tolerability for lateral and angular misalignment, transferring energy through different media including tissue, liquid, air, wood, metal, and fabrics. This addresses a critical issue present in ultrasound approaches. These findings suggest that a magnetically actuated triboelectric generator can be an alternative technology capable of overcoming the medium-related challenges of ultrasound, providing power to medical implants.

14 July 2024 in Journal of the Mechanics and Physics of Solids
Verified
Journal Article
Closed access
ZZZichen Zhao
Zichen Zhao
RARaudel Avila
Raudel Avila
DBDongjun Bai
Dongjun Bai
DXDanli Xia
Danli Xia
ESEnxi She
Enxi She
ZXZhaoqian Xie
Zhaoqian Xie

3 October 2025 in Science Advances
Verified
Journal Article
Open access
SPSun Young Park
Sun Young Park
SKSoo Hyun Kim
Soo Hyun Kim
UBUnseong Baik
Unseong Baik
SHSeung Jae Huh
Seung Jae Huh
RARaudel Avila
Raudel Avila
YJYei Hwan Jung
Yei Hwan Jung
Endovascular aneurysm repair, a treatment for abdominal aortic aneurysms, carries the risk of recurrence due to endoleaks following stent graft implantation. Since these leaks do not present with specific symptoms, regular follow-up is necessary; however, now, only imaging-based monitoring is available. This study proposes an ultrathin flexible sensor inserted endovascularly with a stent to detect type I endoleaks, which pose the highest rupture risk. A coplanar capacitive sensor was attached to the stent graft using a specially developed flexible thermal adhesive to monitor blood leakage, without compromising the stent graft’s function. It seamlessly folds and unfolds with the stent, allowing implantation through catheter-based procedures. Experimental validation confirmed that the sensor does not induce blood leakage and demonstrated long-term stability and functionality under vascular and dynamic conditions. This technology enables wireless monitoring of endoleak status, facilitates timely intervention, and improves postoperative outcomes by reducing the risk of recurrent aneurysms.

1 December 2025 in npj Soft Matter
Verified
Journal Article
Open access
PDF file
RMRitika Raj Menghani
Ritika Raj Menghani
RARaudel Avila
Raudel Avila
Substrate materials play a critical role in the design of soft and stretchable bioelectronic systems, providing encapsulation and enabling functional integration with biological tissue in both wearable and implantable applications. This review outlines key design considerations for substrates, including commonly used materials, mechanical requirements, biological compatibility, and additional engineered functionalities. The article concludes with a summary and an outlook on future directions in substrate development for soft bioelectronic applications.

1 January 2026 in Research
Verified
Journal Article
Open access
XGXu Guo
Xu Guo
RARaudel Avila
Raudel Avila
ZWZiqi Wu
Ziqi Wu
XWXinning Wang
Xinning Wang
PXPeixin Xu
Peixin Xu
Zhaoqian XieZhaoqian Xie
Zhaoqian Xie
Wearable haptic systems enable natural and intuitive human–machine interaction, with growing relevance in immersive entertainment, physical rehabilitation, social communication, and personalized therapy. By delivering real-time tactile feedback via electrical, thermal, and mechanical stimulation, individually or in combination, these systems enhance user engagement and enable more dynamic and responsive digital interactions. This review presents a structured overview of the design principles, actuation mechanisms, and material architectures that define current wearable haptic technologies. We evaluate the strengths and limitations of major feedback modalities and highlight how system-level designs are tailored to specific use cases, from immersive gaming and training simulations to postoperative rehabilitation and emotion-sensitive communication. We also identify key challenges in miniaturization, multimodal integration, user comfort, and long-term wearability. The insights presented here aim to inform the development of next-generation haptic interfaces that are adaptive, scalable, and deployable in real-world applications.

18 December 2025 in Advanced Functional Materials
Verified
Journal Article
Open access
JPJeonghwan Park
Jeonghwan Park
HAHak-Young Ahn
Hak-Young Ahn
MSMinho Seong
Minho Seong
TKTaehoon Kim
Taehoon Kim
YZYulin Zhou
Yulin Zhou
John A. RogersJohn A. Rogers
John A. Rogers
Conventional strategies for the management of acute pain have significant limitations. Pharmaceutical approaches carry risks for addiction and misuse. Standard implantable devices require secondary surgeries for removal and physical tethers to external systems for power and control. Recent work on bioresorbable electrical stimulators overcomes certain of these drawbacks, but existing versions still depend on transcutaneous leads. Here, we introduce a platform that employs thermal mechanisms for nerve block to bypass some of these limitations. The system integrates both a Joule heating element and a resistive temperature sensor in a soft cuff structure as a nerve interface, in which most of the materials are bioresorbable over a clinically relevant timeframe. This design enables precise control of nerve temperature within a safe range (≤45°C) for effective nerve block through a feedback‐guided strategy that continuously monitors temperature and adjusts current in real time. Options for wireless power delivery eliminate the need for external interfaces. Small animal model studies confirm the reversible and non‐invasive operation of this system. The results demonstrate effective suppression of compound nerve action potentials in response to thermal stimulation, with recovery of nerve conduction upon cooling. These findings highlight the potential of this platform as a safe and effective solution to acute pain management.