James R. Sanger

James R. Sanger

Auto-generated profile, based on publicly available information

James R. Sanger

Department of Plastic Surgery, The Medical College of Wisconsin, Milwaukee, WI, USA

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 1991 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
BGBrad K. Grunert
Brad K. Grunert
JSJames R. Sanger
James R. Sanger
HMHani S. Matloub
Hani S. Matloub
NYN. John Yousif
N. John Yousif

1 January 1985 in Muscle & Nerve
Verified
Journal Article
Closed access
PDF file
JWJacqueline J. Wertsch
Jacqueline J. Wertsch
JSJames R. Sanger
James R. Sanger
HMHani S. Matloub
Hani S. Matloub

1 May 1996 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
PDF file
HMHani S. Matloub
Hani S. Matloub
WDWilliam W. Dzwierzynski
William W. Dzwierzynski
SEScott Erickson
Scott Erickson
JSJames R. Sanger
James R. Sanger
NYN. John Yousif
N. John Yousif
VMVincent Mouneke
Vincent Mouneke

1 December 2014 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
JMJ.A. Machol
J.A. Machol
PLP. Langenstroer
P. Langenstroer
JSJ.R. Sanger
J.R. Sanger

1 December 1992 in Annals of Plastic Surgery
Verified
Journal Article
Closed access
HMHani S. Matloub
Hani S. Matloub
PJPaul Jensen
Paul Jensen
BGBrad K. Grunert
Brad K. Grunert
JSJames R. Sanger
James R. Sanger
NYN. John Yousif
N. John Yousif
This study evaluated two types of prosthetic mesh and autogenous fascia in long-term abdominal wall reconstruction for rats. Marlex mesh, Gore-Tex patch, and autogenous fascia were implanted and left in place for 1 year. Materials were removed and evaluated using tensile strength of the material, tensile strength of the suture line, and adhesions. No change in the tensile strength of any of the materials were found at 1 year follow-up. Tensile strengths were significantly greater for Gore-Tex patch and Marlex mesh than the autogenous fascia. The Marlex mesh, however, had a weak and a strong tensile strength direction. These were significantly different (p < 0.05). Suture line tensile strength was greater for autogenous fascia and Marlex mesh than it was for the Gore-Tex patch, which was significantly weaker (p < 0.05). The greatest number of adhesions were seen in the Marlex mesh group. No significant difference was present in adhesions between Gore-Tex patch and autogenous fascia. In summary, autogenous fascia showed virtually no adhesions and good suture line strength. While it was the weakest of the three materials examined, the strength was still within the normal range and adequate for abdominal wall reconstruction.

19 June 2014 in HAND
Verified
Journal Article
Closed access
NFNicholas A. Flugstad
Nicholas A. Flugstad
JSJames R. Sanger
James R. Sanger
DHDonald A. Hackbarth
Donald A. Hackbarth
A 20-year-old male was evaluated for winging of the scapula and an enlarging axillary mass of 4 months' duration. Imaging demonstrated a multiloculated cystic lesion that extended into the axilla and superiorly displaced the brachial plexus and axillary vessels surrounding an exostotic mass arising from the scapula. Surgery confirmed the mass to be a benign osteochondroma with a reactive bursa. The long thoracic nerve was intact and the serratus anterior muscle contracted normally with nerve stimulation. The scapular winging resolved completely following resection of the osteochondroma, and shoulder and arm function remained normal. A literature review of causes of pseudo-winging of the scapula was performed. Scapular osteochondroma is a rarely reported cause of scapula winging.