Cenap Zeybek

Cenap Zeybek

Auto-generated profile, based on publicly available information

Cenap Zeybek

Pediatric Cardiology, Yeni Yuzyıl University, Istanbul, TUR

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2010 in Pediatrics International
Verified
Journal Article
Closed access
PDF file
CZCenap Zeybek
Cenap Zeybek
ACAhmet Celebi
Ahmet Celebi
CACigdem Aktuglu‐Zeybek
Cigdem Aktuglu‐Zeybek
HOHasan Onal
Hasan Onal
YYYalim Yalcin
Yalim Yalcin
AAAhmet Aydın
Ahmet Aydın

31 October 2007 in Pediatrics International
Verified
Journal Article
Closed access
PDF file
CZCenap Zeybek
Cenap Zeybek
YYYalim Yalcin
Yalim Yalcin
AEAbdullah Erdem
Abdullah Erdem
TPTugcin Bora Polat
Tugcin Bora Polat
AAA Cigdem Aktuglu‐Zeybek
A Cigdem Aktuglu‐Zeybek
ACAhmet Celebi
Ahmet Celebi

2 June 2009 in Pediatric Cardiology
Verified
Journal Article
Closed access
PDF file
CZCenap Zeybek
Cenap Zeybek
CACigdem Aktuglu-Zeybek
Cigdem Aktuglu-Zeybek
HOHasan Onal
Hasan Onal
SASüheyla Altay
Süheyla Altay
AEAbdullah Erdem
Abdullah Erdem
ACAhmet Celebi
Ahmet Celebi

19 May 2021 in Cureus
Verified
Journal Article
Open access
AZAdil Umut Zubarioglu
Adil Umut Zubarioglu
ÖYÖzgür Yıldırım
Özgür Yıldırım
CZCenap Zeybek
Cenap Zeybek
IBİsMail Balaban
İsMail Balaban
VYVolkan Yazıcıoglu
Volkan Yazıcıoglu
BABahruz Aliyev
Bahruz Aliyev
Objectives: We aimed to validate the vasoactive-ventilation-renal (VVR) score and to compare it with other indices as a predictor of outcome in neonates recovering from surgery for critical congenital heart disease. We also sought to determine the optimal time at which the VVR score should be measured. Methods: We retrospectively reviewed neonates recovering from cardiac surgery between July 2017 and June 2020. The VVR score was calculated at admission, 24, 48, and 72 hours postoperatively. Max values, defined as the highest of the four scores, were also recorded. The main end result of interest was a composite outcome which included prolonged intensive care unit stay and mortality. Receiver operating characteristic curves were generated, and areas under the curve with 95% confidence intervals were calculated for all time points. Multivariable logistic regression modeling was also performed. Results: We reviewed 73 neonates and 21 of them showed composite outcomes. The area under the curve value for VVR score as a predictor of composite outcome was greatest at postoperative 72-hour max (AUC= 0.967; 95% confidence interval, (0.927-1). On multivariable regression analysis, the VVR max 72 hours remained a strong independent predictor of prolonged ICU stay and mortality (odds ratio, 1.452; 95% confidence interval, 1.036-2.035). Conclusions: We validated the utility of the VVR score in neonatal cardiac surgery for critical congenital heart disease. The VVR follow-up in postoperative 72 hours is superior to other indices and especially the maximum VVR value is a potentially powerful clinical tool to predict ICU stay and mortality.

1 September 2010
Verified
Journal Article
Closed access
AEAbdullah Erdem
Abdullah Erdem
NANuman Ali Aydemir
Numan Ali Aydemir
HDHalil Demir
Halil Demir
CZCenap Zeybek
Cenap Zeybek
TSTürkay Sarıtaş
Türkay Sarıtaş
ACAhmet Celebi
Ahmet Celebi

1 January 2012 in Turk Kardiyoloji Dernegi Arsivi-Archives of the Turkish Society of Cardiology
Verified
Journal Article
Closed access
CZCenap Zeybek
Cenap Zeybek
We report the successful closure of an extracardiac Fontan fenestration with a bio-absorbable device, which may be refenestrated by a transcatheter route when needed, in a 10-year-old boy. The patient presented with cyanosis two years after an extracardiac Fontan operation. Echocardiography revealed a moderate shunt from the Fontan circulation into the systemic circulation with a mean pressure gradient of 3-4 mmHg. Treadmill testing revealed a significant decrease in oxygen saturation (down to the low 50's from a baseline level of 80-85%). Cardiac catheterization revealed normal pressure in the Fontan circuit. A temporary balloon occlusion test showed that the defect was suitable for permanent occlusion. The fenestration was then occluded by a bio-absorbable Biostar (NMT medical, Boston, USA) atrial septal occluder device. The oxygen saturation on room air increased up to 95% after closure.