Jian Teng

Jian Teng

Auto-generated profile, based on publicly available information

Jian Teng

Science and Technology on Plasma Physics Laboratory, Laser Fusion Research Center, China Academy of Engineering Physics 1 , Mianyang 621900, People’s Republic of China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2024 in Matter and Radiation at Extremes
Verified
Journal Article
Open access
PDF file
CTChao Tian
Chao Tian
MYMinghai Yu
Minghai Yu
LSLianqiang Shan
Lianqiang Shan
FWFengjuan Wu
Fengjuan Wu
BBBi Bi
Bi Bi
BZBaohan Zhang
Baohan Zhang
We present an application of short-pulse laser-generated hard x rays for the diagnosis of indirectly driven double shell targets. Cone-inserted double shell targets were imploded through an indirect drive approach on the upgraded SG-II laser facility. Then, based on the point-projection hard x-ray radiography technique, time-resolved radiography of the double shell targets, including that of their near-peak compression, were obtained. The backlighter source was created by the interactions of a high-intensity short pulsed laser with a metal microwire target. Images of the target near peak compression were obtained with an Au microwire. In addition, radiation hydrodynamic simulations were performed, and the target evolution obtained agrees well with the experimental results. Using the radiographic images, areal densities of the targets were evaluated.

1 January 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ZLZihao Li
Zihao Li
NKNing Kang
Ning Kang
JTJian Teng
Jian Teng
ZZZhimeng Zhang
Zhimeng Zhang
JXJiajie Xie
Jiajie Xie
TLTingshuai Li
Tingshuai Li
The Thomson parabola ion spectrometer is vulnerable to intense electromagnetic pulses (EMPs) generated by a high-power laser interacting with solid targets. A metal shielding cage with a circular aperture of 1 mm diameter is designed to mitigate EMPs induced by a picosecond laser irradiating a copper target in an experiment where additionally an 8-ns delayed nanosecond laser is incident into an aluminum target at the XG-III laser facility. The implementation of the shielding cage reduces the maximum EMP amplitude inside the cage to 5.2 kV/m, and the simulation results indicate that the cage effectively shields electromagnetic waves. However, the laser-accelerated relativistic electrons which escaped the target potential accumulate charge on the surface of the cage, which is responsible for the detected EMPs within the cage. To further alleviate EMPs, a lead wall and an absorbing material (ECCOSORB AN-94) were added before the cage, significantly blocking the propagation of electrons. These findings provide valuable insights into EMP generation in large-scale laser infrastructures and serve as a foundation for electromagnetic shielding design.

1 November 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
JTJ. Teng
J. Teng
LSL. Q. Shan
L. Q. Shan
BZB. Zhu
B. Zhu
ZDZ. G. Deng
Z. G. Deng
SHS. K. He
S. K. He
YGY. Q. Gu
Y. Q. Gu
A compact online proton spectrometer based on a CMOS plate detector was proposed for the diagnosis of picosecond intense-laser accelerated protons. Inside the CMOS plate detector, a composite structure that composed of a scintillator screen, a fiber optic plate (FOP), and a CMOS sensor was designed to detect the protons safely and efficiently. The scintillator screen converted the incident protons to visible light, which, in turn, was collected by using the FOP and detected by using the CMOS sensor. An additional aluminum housing was designed to decrease the strong electromagnetic pulse (EMP) impact on the electronic readout system from picosecond laser–plasma interaction. This online spectrometer is compact and cost-effective than the system based on the micro-channel plate or scintillator screen in combination with an electron multiplying CCD camera and has better resistance to radiation damage than the system based on a single CMOS sensor.