1 October 2005 in Journal of Bone and Joint Surgery
Background: Several reference axes are used to establish femoral rotational alignment during total knee arthroplasty, but debate continues with regard to which axis is most accurately and easily identified during surgery. Computer-assisted navigation systems have been developed in an attempt to more accurately and consistently align implants during total knee arthroplasty, but it is unknown if navigation systems can improve the accuracy of femoral rotational alignment as compared with that achieved with more traditional techniques involving mechanical guides. The purposes of the present study were to characterize the variability associated with femoral rotational alignment techniques and to determine whether the use of a computer-assisted surgical navigation system reduced this variability. Methods: Eleven orthopaedic surgeons used five alignment techniques (including one computer-assisted technique and four traditional techniques) to establish femoral rotational alignment axes on ten cadaveric specimens, and the orientation of these axes was recorded with use of a navigation system. These derived axes were compared against a reference transepicondylar axis on each femur that was established after complete dissection of all soft tissues. Results: There was no difference between the mean errors of all five techniques (p > 0.11). Only 17% of the knees were rotated <5° from the reference transepicondylar axis, with alignment errors ranging from 13° of internal rotation to 16° of external rotation. There were significant differences among the surgeons with regard to their ability to accurately establish femoral rotational alignment axes (p < 0.001). Conclusions: All techniques resulted in highly variable rotational alignment, with no technique being superior. This variability was primarily due to the particular surgeon who was performing the alignment procedure. A navigation system that relies on directly digitizing the femoral epicondyles to establish an alignment axis did not provide a more reliable means of establishing femoral rotational alignment than traditional techniques did.
4 April 2018 in Journal of Bone and Joint Surgery
Background: Morbidly obese patients with severe osteoarthritis benefit from successful total joint arthroplasty. However, morbid obesity increases the risk of complications. Because of this, some surgeons enforce a body mass index (BMI) eligibility criterion above which total joint arthroplasty is denied. In this study, we investigate the trade-off between avoiding complications and restricting access to care when enforcing BMI-based eligibility criteria for total joint arthroplasty. Methods: In this retrospective cohort study, the Veterans Health Administration (VHA) Corporate Data Warehouse (CDW) and Veterans Affairs Surgical Quality Improvement Program (VASQIP) databases were reviewed for patients undergoing total joint arthroplasty from October 2011 through September 2014. We determined, if various BMI eligibility criteria had been enforced over that period of time, how many short-term complications would have been avoided, how many complication-free surgical procedures would have been denied, and the positive predictive value of BMI eligibility criteria as tests for major complications. To provide a frame of reference, we also determined what would have happened if eligibility for total joint arthroplasty were arbitrarily determined by flipping a coin. Results: In this study, 27,671 total joint arthroplasties were reviewed. With a BMI criterion of ≥40 kg/m2, 1,148 patients would have been denied a surgical procedure free of major complications, and 83 patients would have avoided a major complication. The positive predictive value of a complication using a BMI of ≥40 kg/m2 as a test for major complications was 6.74% (95% confidence interval [CI], 5.44% to 8.33%). The positive predictive value of a complication using a BMI criterion of 30 kg/m2 was 5.33% (95% CI, 4.99% to 5.71%). Flipping a coin had a positive predictive value of 5.05%. Conclusions: A 30 kg/m2 criterion for total joint arthroplasty eligibility is marginally better than flipping a coin and should not determine surgical eligibility. With a BMI criterion of ≥40 kg/m2, the number of patients denied a complication-free surgical procedure is about 14 times larger than those spared a complication. Although the acceptable balance between avoiding complications and providing access to care can be debated, such a quantitative assessment helps to inform decisions regarding the advisability of enforcing a BMI criterion for total joint arthroplasty. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
1 November 2006 in Clinical Orthopaedics and Related Research
Although various techniques are advocated to establish tibial rotational alignment during total knee arthroplasty, it is unknown which is most repeatable. We evaluated the precision and accuracy of five tibial rotational alignment techniques to determine whether computer-assisted navigation systems can reduce variability of tibial component rotational alignment when compared to traditional instrumentation. Eleven orthopaedic surgeons used four computer-assisted techniques that required identification of anatomical landmarks and one that used traditional extramedullary instrumentation to establish tibial rotational alignment axes on 10 cadaver legs. Two computer-assisted techniques (axes between the most medial and lateral border of the tibial plateau, and between the posterior cruciate ligament [PCL] and the anterior tibial crest) and the traditional technique were least variable, with standard deviations of 9.9°, 10.8°, and 12.1°, respectively. Computer-assisted techniques referencing the tibial tubercle (axes between the PCL and the medial border or medial ⅓ of the tubercle) were most variable, with standard deviations of 27.4° and 28.1°. The axis between the medial border of the tibial tubercle and the PCL was internally rotated compared to the other techniques. None of the techniques consistently established tibial rotational alignment, and navigation systems that establish rotational alignment by identifying anatomic landmarks were not more reliable than traditional instrumentation. Level of Evidence: Level I, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.
19 March 2014 in Journal of Bone and Joint Surgery
Xamine how many diabetic patients scheduled for primary total joint arthroplasty underwent a delay because of an HbA1c value of >7.0%, how many subsequently achieved this goal, and how much time was necessary to achieve this goal. Methods: The study involved a retrospective chart review at one Veterans Affairs medical center. Patients with an HbA1c of >7.0% were referred to their primary care provider for better diabetic control. Unless reduction of the HbA1c to ≤7.0% was deemed medically inadvisable, surgery proceeded only after the patient returned with an HbA1c of ≤7.0%. Results: A total of 404 diabetic patients were scheduled for total joint arthroplasty. In fifty-nine cases, the surgery was delayed because of an HbA1c of >7.0%. Thirty-five of these patients were able to reduce the HbA1c level to ≤7.0% after a median of 141 days (range, seven to 1043 days), and twenty-four failed to achieve this goal. If an HbA1c goal of ≤8.0% had been used, the surgery would have been delayed in thirty cases, and twenty-one of these patients would have subsequently achieved the goal. Conclusions: When establishing a goal designed to reduce perioperative risks, there should be an expectation that the goal is achievable. Overall, an HbA1c of ≤7.0% was achieved by 380 of the 404 diabetic patients (94%; 95% confidence interval [CI], 91% to 96%), but it was achieved by only thirty-five (59%; 95% CI, 46% to 72%) of the fifty-nine patients presenting with an HbA1c of >7.0%. An HbA1c of 8.0% was achieved by 395 (98%; 95% CI, 96% to 99%) of the diabetic patients and by twenty-one (70%; 95% CI, 50% to 85%) of the thirty patients presenting with an HbA1c of >8.0%. Achieving an HbA1c value of ≤7.0% may not be possible for certain diabetic patients, and such a requirement may risk access to total joint arthroplasty treatment. Level of Evidence: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence....
1 October 2010 in Clinical Orthopaedics and Related Research
Various landmarks can guide tibial component rotational alignment in routine TKA, but with the deeper tibial resection levels common in complex primary and revision TKAs, it is unknown whether these landmarks remain reliable. We asked whether three techniques for determining tibial component rotation based on local anatomic landmarks are reliable deeper tibial resection levels. The femoral transepicondylar axis was identified by three independent reviewers on MR images of knees from 24 men and 24 women and transposed at a traditional tibial resection level and at the level of the proximal, middle, and distal parts of the proximal tibiofibular joint. Three axes were drawn on axial slices at these levels: the geometric center of the tibial plateau to the medial 1/3 of the tubercle, the posterior condylar line of the tibia, and the largest mediolateral dimension of the tibia. These lines were compared with the transposed femoral epicondylar axis line. The posterior condylar line of the tibia is the least variable local landmark for tibial component positioning at deep resection levels. Assuming the normal posterior condylar line of the tibia is visible at revision, setting the tibial component at 10° external rotation with respect to the posterior condylar axis of the tibia gets the tibial component within 10° of proper rotation in 86% to 98% of patients, even to the distal part of the proximal tibiofibular joint. The experienced surgeon then can adjust this position based on cues from an assortment of other axes.
1 October 2008 in Journal of Bone and Joint Surgery
Hesized that establishing femoral rotational alignment with the use of kinematic techniques is more accurate and precise (repeatable) than the use of anatomic techniques and that establishing femoral rotational alignment by averaging the results of different alignment techniques is more accurate and precise than the use of a single technique....