Nicholas Kaufmann

Nicholas Kaufmann

Auto-generated profile, based on publicly available information

Nicholas Kaufmann

SCHOTTEL Hydro

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2023 in Renewable Energy
Verified
Journal Article
Open access
MMMarinos Manolesos
Marinos Manolesos
LCL. Chng
L. Chng
NKN. Kaufmann
N. Kaufmann
POPablo Ouro
Pablo Ouro
DND. Ntouras
D. Ntouras
GPG. Papadakis
G. Papadakis

14 February 2021 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
KVKevin Volkmer
Kevin Volkmer
NKNicholas Kaufmann
Nicholas Kaufmann
Thomas CarolusThomas Carolus
Thomas Carolus

1 June 2021 in Renewable Energy
Verified
Journal Article
Open access
TLThomas Lake
Thomas Lake
JHJack Hughes
Jack Hughes
MTMichael Togneri
Michael Togneri
AWAlison J. Williams
Alison J. Williams
PJPenny Jeffcoate
Penny Jeffcoate
IMIan Masters
Ian Masters

25 August 2023 in Journal of Ocean Engineering and Marine Energy
Verified
Journal Article
Open access
PDF file
Alessandro CaponeAlessandro Capone
Alessandro Capone
Fabio Di FeliceFabio Di Felice
Fabio Di Felice
Francesco SalvatoreFrancesco Salvatore
Francesco Salvatore
HMHarish Maddukkari
Harish Maddukkari
NKNicholas Kaufmann
Nicholas Kaufmann
RSRalf Starzmann
Ralf Starzmann
The impact of cavitation and inflow perturbation by an upstream support structure on the performance of a horizontal-axis tidal turbine has been studied by experiments at model scale in a depressurized water channel at CNR-INM. Measurements of turbine generated power and thrust have been carried out at varying channel flow speed, tip-speed ratio, and cavitation number. The visualization of cavitation patterns has been associated with the performance measurements to identify the role played by different cavitation types on turbine behavior. Radiated noise measurement were also performed to assess the impact of cavitation phenomena on turbine induced acoustic signature.

19 December 2022 in International Marine Energy Journal
Verified
Journal Article
Open access
PDF file
RSRalf Starzmann
Ralf Starzmann
NKNicholas Kaufmann
Nicholas Kaufmann
PJPenny Jeffcoate
Penny Jeffcoate
RPRay Pieroway
Ray Pieroway
MGMaricarmen Guerra
Maricarmen Guerra
AHAlex Hay
Alex Hay
As the tidal energy industry starts to mature towards commercial projects a key focus is on reliable power performance. As for any marine application, fouling poses a potential performance reduction risk for instream turbine deployments. SCHOTTEL HYDRO have developed their current commercial SCHOTTEL Instream Turbines. Four drivetrains with 6.3m rotors were deployed on the surface platform PLAT-I by Sustainable Marine Energy. One of PLAT-Is key features is access to the turbines for inspection and maintenance in situ. The system has undergone sea testing from 2017 to 2021 in Scotland and Nova Scotia (Canada). This paper presents the hydrodynamic rotor performance reduction due to fouling based on full-scale experimental results. An in-house blade element momentum model is used to quantify the changes of the hydrodynamic forces in terms of lift and drag for the hydrofoils used. Furthermore, the effect of fouling on the downstream wake was quantified in the field. The performance reduction due to fouling is significant and leads to a power drop of up to 43%, whereas the thrust is reduced by 25%. This is also reflected in a reduction of the turbine’s downstream wake as a “fouled” rotor extracts less energy from the flow. Modifications of the polar data, used for semi-empirical performance predictions, are able to predict the effect of fouling on the rotor performance. In general, the results derived from the testing prove the significance of access to the turbines in order to avoid reduction in the turbines’ performance due to fouling.

8 September 2025 in Proceedings of the European Wave and Tidal Energy Conference
Verified
Journal Article
Closed access
PDF file
UZUrs Zweiffel
Urs Zweiffel
GJGeorg Jacobs
Georg Jacobs
JRJulian Röder
Julian Röder
TSTim Scholz
Tim Scholz
MZMaximilian Zweiffel
Maximilian Zweiffel
NKNicholas Kaufmann
Nicholas Kaufmann
Tidal turbines show predictable energy output. Thus, this form of energy generation has potential to supplement established, but less predictable, renewable energy systems like PV and wind energy. However, the levelized cost of electricity (LCOE) of tidal energy is roughly ten times higher than those of solar and wind energy. Therefore, the LCOE must be reduced to ascertain economic competitiveness. A high share of the LCOE consists of the maintenance costs. Thus, decreasing the maintenance costs is an effective way to reduce the LCOE. The current lack of monitoring systems necessitates a time-based maintenance schedule. Compared to predictive maintenance systems, this results in premature and sometimes unnecessary service. The application of a load monitoring system and corresponding maintenance plans allows to maintain the turbines based on the loads experienced, reducing not needed service and therefore maintenance costs. A novel concept for a load monitoring system for tidal turbines based on strain measurements has been developed. The considered tidal turbine system consists of a support arm structure which is attached to a floating vessel. The strains are measured with strain gauges attached to the bespoken support arm structure. To reduce effects of the environmental conditions, strains are measured on the arm above sea level and not at the rotor. Measuring the strains on the support arm distant from the rotor necessitates a robust transfer function to determine the rotor loads. In this paper, the development and optimization of the transfer function is presented. FEM simulations are used to determine the strains on the arm for varying static rotor loads. The simulation results are used to derive a transfer function from arm strain to rotor loads. The transfer function with strain measurements on the support arm in the field as an input comprises a real-time capable load monitoring system. To develop a cheap but reliable system, the number of measuring points of the system needs to be minimized, while still achieving a robust transfer function. The influence of the strain gauge’s measuring range is also considered for the robustness of the transfer function. An optimization algorithm is used to find the minimal amount of measuring points for a 1 % relative error between applied and measured load. The layout is optimized regarding the condition of the transfer function to mispositioning and misalignment measuring points.