Paul R. Selvin

Paul R. Selvin

Auto-generated profile, based on publicly available information

Paul R. Selvin

Department of Physics, University of Illinois, Urbana, IL 61801

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2000 in Nature Structural & Molecular Biology
Verified
Journal Article
Closed access
PSPaul R. Selvin
Paul R. Selvin

1 June 2002 in Annual Review of Biophysics
Verified
Journal Article
Closed access
PSPaul R. Selvin
Paul R. Selvin
▪ Abstract Using luminescent lanthanides, instead of conventional fluorophores, as donor molecules in resonance energy transfer measurements offers many technical advantages and opens up a wide range of new applications. Advantages include farther measurable distances (∼100 Å) with greater accuracy, insensitivity to incomplete labeling, and the ability to use generic relatively large labels, when necessary. Applications highlighted include the study of ion channels in living cells, protein-protein interaction in cells, DNA-protein complexes, and high-throughput screening assays to measure peptide dimerization associated with DNA transcription factors and ligand-receptor interactions.

1 August 1999 in Analytical Biochemistry
Verified
Journal Article
Closed access
EGElise Burmeister Getz
Elise Burmeister Getz
MXMing Xiaob
Ming Xiaob
TCTania Chakrabartyb
Tania Chakrabartyb
RCRoger Cookea
Roger Cookea
PSPaul R. Selvin
Paul R. Selvin

19 April 2004 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
MGMatthew P. Gordon
Matthew P. Gordon
THTaekjip Ha
Taekjip Ha
PSPaul R. Selvin
Paul R. Selvin
Conventional light microscopy is limited in its resolving power by the Rayleigh limit to length scales on the order of 200 nm. On the other hand, spectroscopic techniques such as fluorescence resonance energy transfer cannot be used to measure distances >10 nm, leaving a “gap” in the ability of optical techniques to measure distances on the 10- to 100-nm scale. We have previously demonstrated the ability to localize single dye molecules to a precision of 1.5 nm with subsecond time resolution. Here we locate the position of two dyes and determine their separation with 5-nm precision, using the quantal photobleaching behavior of single fluorescent dye molecules. By fitting images both before and after photobleaching of one of the dyes, we may localize both dyes simultaneously and compute their separation. Hence, we have circumvented the Rayleigh limit and achieved nanometer-scale resolution. Specifically, we demonstrate the technique by measuring the distance between single fluorophores separated by 10–20 nm via attachment to the ends of double-stranded DNA molecules immobilized on a surface. In addition to bridging the gap in optical resolution, this technique may be useful for biophysical or genomic applications, including the generation of super-high-density maps of single-nucleotide polymorphisms.

25 April 2006 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
ETErdal Toprak
Erdal Toprak
JEJoerg Enderlein
Joerg Enderlein
SSSheyum Syed
Sheyum Syed
SMSean A. McKinney
Sean A. McKinney
RPRolfe G. Petschek
Rolfe G. Petschek
PSPaul R. Selvin
Paul R. Selvin
The centroid of a fluorophore can be determined within ≈1.5-nm accuracy from its focused image through fluorescence imaging with one-nanometer accuracy (FIONA). If, instead, the sample is moved away from the focus, the point-spread-function depends on both the position and 3D orientation of the fluorophore, which can be calculated by defocused orientation and position imaging (DOPI). DOPI does not always yield position accurately, but it is possible to switch back and forth between focused and defocused imaging, thereby getting the centroid and the orientation with precision. We have measured the 3D orientation and stepping behavior of single bifunctional rhodamine probes attached to one of the calmodulins of the light-chain domain (LCD) of myosin V as myosin V moves along actin. Concomitant with large and small steps, the LCD rotates and then dwells in the leading and trailing position, respectively. The probe angle relative to the barbed end of the actin (β) averaged 128° while the LCD was in the leading state and 57° in the trailing state. The angular difference of 71° represents rotation of LCD around the bound motor domain and is consistent with a 37-nm forward step size of myosin V. When β changes, the probe rotates ±27° azimuthally around actin and then rotates back again on the next step. Our results remove degeneracy in angles and the appearance of nontilting lever arms that were reported.

11 August 2005 in Nature
Verified
Journal Article
Closed access
PDF file
DPDavid J. Posson
David J. Posson
PGPinghua Ge
Pinghua Ge
CMChristopher Miller
Christopher Miller
FBFrancisco Bezanilla
Francisco Bezanilla
PSPaul R. Selvin
Paul R. Selvin