Chintamani Vyjayanthi

Chintamani Vyjayanthi

Auto-generated profile, based on publicly available information

Chintamani Vyjayanthi

National Institute of Technology Goa

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2021 in IEEE Systems Journal
Verified
Journal Article
Closed access
AMAjit A. Muzumdar
Ajit A. Muzumdar
CMChirag N. Modi
Chirag N. Modi
MMMadhu G. M
Madhu G. M
CVChintamani Vyjayanthi
Chintamani Vyjayanthi
The consumer’s short-term load forecasting plays an essential role in microgrid energy distribution. However, the load forecasting at consumer level is more challenging than at substation level due to high volatility and uncertainty in energy consumption. In literature, many machine learning-based forecasting models have been explored. However, there is a need of developing a robust and accurate model to handle highly inconsistent energy consumption. In this article, we propose a robust and accurate model for consumer’s short-term load forecasting, which uses feasible techniques such as random forest, support vector regressor, and long short-term memory as base predictors to handle varying traits of energy consumption. For the final decision-making on forecasting result of these predictors, it assigns weights to each predictor dynamically as per the forecasting efficacy. The proposed model is tested on different consumer’s varying traits of energy consumption. The experimental results show that the proposed model achieves forecasting error reduction by 3.46 and 2.53 in terms of average RMSE and MAE, respectively, in comparison with the existing models. It is robust and accurate even in presence of highly volatile and uncertain load patterns, and thus, it can better fit for microgrid energy management.

19 March 2022 in Journal of Cleaner Production
Verified
Journal Article
Closed access
AMAjit Muzumdar
Ajit Muzumdar
CMChirag N. Modi
Chirag N. Modi
CVC. Vyjayanthi
C. Vyjayanthi

1 June 2021 in Journal of Network and Computer Applications
Verified
Journal Article
Closed access
AMAjit Muzumdar
Ajit Muzumdar
CMChirag Modi
Chirag Modi
MGMadhu G.M.
Madhu G.M.
CVC. Vyjayanthi
C. Vyjayanthi

24 February 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
AMAjit Muzumdar
Ajit Muzumdar
CMChirag Modi
Chirag Modi
CVC. Vyjayanthi
C. Vyjayanthi

17 July 2023 in IEEE Access
Verified
Journal Article
Open access
NNNivedita Naik
Nivedita Naik
CVC. Vyjayanthi
C. Vyjayanthi
CMChirag N. Modi
Chirag N. Modi
Dual Active Bridge (DAB) converter is well suited for off-board fast Electric Vehicle Charging Stations (EVCS) and in DC microgrid-connected EVCS applications. However, proper modification in DAB converter topology is crucial for fast charging, as the charging current is very high, and any oscillations would shorten the EV battery life. As per literature, DAB converter topology integrated with a series inductor at the output for EV battery charging reduces the output current ripple by 40%. However, as per our observation, potentially unstable dynamics are introduced in the system with the inclusion of an LC filter. This affects the controller stability; hence, these dynamics must be damped using active or passive damping. Passive damping is less efficient due to the considerable losses it produces, partly induced by low-frequency noise and partly from switching-frequency noise. Also, placing the damping at the selective resonant frequency is very complex. In comparison, active damping offers selective placement and loss reduction. This paper presents the DAB converter mathematical modeling using the generalized average model (GAM) and the average output current linearization model (AOCLM). The paper presents stability analysis and proposes a novel and robust approach to control the dynamics in the current and voltage control loops during EV charging, thereby reducing battery degradation. The charge flow to the battery is controlled using Constant Current Constant Voltage (CCCV) algorithm. The proposed scheme also eliminates the need for extra sensors by selectively attenuating the oscillations at the frequency of interest. The performance of the proposed model for EV fast charging application is verified using MATLAB/Simulink and experimentally validated in a real-time simulator OPAL-RT hardware platform.

7 July 2021 in IEEE Access
Verified
Journal Article
Open access
GMG. M. Madhu
G. M. Madhu
CVC. Vyjayanthi
C. Vyjayanthi
CMChirag N. Modi
Chirag N. Modi
This paper presents the effect of irradiance change in solar photovoltaic (PV) array interconnection schemes under partial shading conditions (PSCs) for optimal selection of PV interconnection schemes in order to extract maximum power (MP) from the PV array. A 4×4 PV array is considered to examine the well-known PV interconnection schemes under different shading scenarios at distinct irradiance conditions. Simulation studies and experimental verification are carried out by considering a 30 W PV panel to analyse the performance of the PV array under various dynamic conditions. Comprehensive analysis in terms of fill factor, output power and mismatching power loss is presented by considering different interconnection schemes under various shading scenarios and irradiance levels. From the simulation studies and experimental verification, it is observed that the irradiance magnitude has a significant impact on the PV power generation from array interconnection schemes under PSCs wherein the performance characteristics of the array interconnection schemes vary with the variation in irradiance levels. It is also identified that the irradiance factor needs to be considered as a design variable while selecting the optimal PV array interconnection schemes for maximum power extraction under PSCs.