1 June 2016 in Circulation: Cardiovascular Interventions
Background—: Approximately one third of patients with symptomatic aortic stenosis have reduced left ventricular ejection fraction (LVEF) before transcatheter aortic valve replacement. The incidence, predictors, and significance of early LVEF recovery after CoreValve transcatheter aortic valve replacement have not been described. Methods and Results—: We studied 156 patients from the CoreValve Extreme and High-Risk trials with LVEF ≤40% at baseline who had 30-day LVEF data. All patients underwent core laboratory echocardiographic assessment of LVEF at baseline, post procedure, discharge, 30 days, 6 months, and 1 year. Early LVEF recovery was defined as an absolute increase of ≥10% in EF at 30 days. One-year outcomes were compared between patients with and without early recovery. Multivariable analysis was performed to determine independent predictors of early recovery. Early LVEF recovery occurred in 62% of patients, generally before discharge. By 30 days LVEF increased >17% compared with baseline in the early recovery group with minimal increase in the no–early recovery group (48.9±8.8% versus 31.5±6.9%; P <0.001). One-year all-cause mortality was numerically (but not statistically) higher in the no–early recovery group (24% versus 12%; P =0.07). Absence of previous myocardial infarction (odds ratio, 0.44; 95% confidence interval, 0.19–1.03) and baseline mean gradient ≥40 mm Hg (odds ratio, 4.59; 95% confidence interval, 1.76–11.96) were identified as predictors of early LVEF recovery. Conclusions—: Nearly two thirds of patients with reduced LVEF will have a marked early improvement after transcatheter aortic valve replacement. Early LVEF recovery is associated with improved clinical outcomes and is most likely among patients with higher baseline aortic valve gradients and no previous myocardial infarction. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01240902.
1 May 2015 in Circulation: Cardiovascular Interventions
Background—: Current American College of Cardiology/American Heart Association guidelines recommend transfer and primary percutaneous coronary intervention (PCI) for ST-segment–elevation myocardial infarction (STEMI) patients within the time limit of first contact to device ≤120 minutes. We determined the hospital-level, patient-level, and process characteristics of timely versus delayed primary PCI for a diverse national sample of transfer patients confined to a travel distance that facilitates the process. Methods and Results—: We studied 14 518 patients transferred from non–PCI-capable hospitals for primary PCI to 398 National Cardiovascular Data Registry Acute Coronary Treatment and Intervention Outcomes Network Registry-Get With The Guidelines hospitals between July 2008 and December 2012. Patients with estimated transfer times >60 minutes (by Google Maps driving times) were excluded from the analysis. Patients achieving first door-to-device time ≤120 minutes were compared with patients with delayed treatment; independent predictors of timely treatment were determined using generalized estimating equations logistic regression models. The median estimated transfer distance was 26.5 miles. First door-to-device ≤120 minutes was achieved in 65% of patients (n=9380); only 37% of the hospitals were high-performing hospitals (defined as risk-adjusted rate, ≥75% of transfer STEMI patients with ≤120-minute first door-to-device time). In addition to known predictors of delay (cardiogenic shock, cardiac arrest, and prolonged door-in door-out time), STEMI referral hospitals’ rural location and longer estimated transfer time were identified as predictors of delay. In this diverse national sample, regional and racial variations in care were observed. Finally, lower PCI hospital annual STEMI volume was a potent predictor of delay. Conclusions—: More than one third of US STEMI patients transferred for primary PCI fail to achieve first door-to-device time ≤120 minutes, despite estimated transfer times <60 minutes. Delays are related to process variables, comorbidities, and lower annual PCI hospital STEMI volumes.
1 November 2023 in Circulation: Cardiovascular Interventions
BACKGROUND: Coronary accessibility following redo–transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 ( P <0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 ( P <0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P <0.001), and the highest at Evolut node 5 (61% versus 32%; P <0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02701283.
30 March 2022 in The American Journal of Cardiology