Tom Eelbode

Tom Eelbode

Auto-generated profile, based on publicly available information

Tom Eelbode

Department of Electrical Engineering (ESAT/PSI), Medical Imaging Research Center, KU Leuven, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
TETom Eelbode
Tom Eelbode
JBJeroen Bertels
Jeroen Bertels
MBMaxim Berman
Maxim Berman
DVDirk Vandermeulen
Dirk Vandermeulen
FMFrederik Maes
Frederik Maes
MBMatthew B. Blaschko
Matthew B. Blaschko
In many medical imaging and classical computer vision tasks, the Dice score and Jaccard index are used to evaluate the segmentation performance. Despite the existence and great empirical success of metric-sensitive losses, i.e. relaxations of these metrics such as soft Dice, soft Jaccard and Lovász-Softmax, many researchers still use per-pixel losses, such as (weighted) cross-entropy to train CNNs for segmentation. Therefore, the target metric is in many cases not directly optimized. We investigate from a theoretical perspective, the relation within the group of metric-sensitive loss functions and question the existence of an optimal weighting scheme for weighted cross-entropy to optimize the Dice score and Jaccard index at test time. We find that the Dice score and Jaccard index approximate each other relatively and absolutely, but we find no such approximation for a weighted Hamming similarity. For the Tversky loss, the approximation gets monotonically worse when deviating from the trivial weight setting where soft Tversky equals soft Dice. We verify these results empirically in an extensive validation on six medical segmentation tasks and can confirm that metric-sensitive losses are superior to cross-entropy based loss functions in case of evaluation with Dice Score or Jaccard Index. This further holds in a multi-class setting, and across different object sizes and foreground/background ratios. These results encourage a wider adoption of metric-sensitive loss functions for medical segmentation tasks where the performance measure of interest is the Dice score or Jaccard index.

10 October 2019
Verified
Book Chapter
Closed access
PDF file
JBJeroen Bertels
Jeroen Bertels
TETom Eelbode
Tom Eelbode
MBMaxim Berman
Maxim Berman
DVDirk Vandermeulen
Dirk Vandermeulen
FMFrederik Maes
Frederik Maes
MBMatthew B. Blaschko
Matthew B. Blaschko

1 June 2021 in Best Practice & Research Clinical Gastroenterology
Verified
Journal Article
Closed access
TETom Eelbode
Tom Eelbode
PSPieter Sinonquel
Pieter Sinonquel
FMFrederik Maes
Frederik Maes
RBRaf Bisschops
Raf Bisschops

15 October 2024 in Gut
Verified
Journal Article
Closed access
PDF file
GAGiulio Antonelli
Giulio Antonelli
DLDiogo Libanio
Diogo Libanio
AGAlbert Jeroen De Groof
Albert Jeroen De Groof
Fons van der SommenFons van der Sommen
Fons van der Sommen
PMPietro Mascagni
Pietro Mascagni
MRMario Dinis Ribeiro
Mario Dinis Ribeiro
Artificial intelligence (AI) holds significant potential for enhancing quality of gastrointestinal (GI) endoscopy, but the adoption of AI in clinical practice is hampered by the lack of rigorous standardisation and development methodology ensuring generalisability. The aim of the Quality Assessment of pre-clinical AI studies in Diagnostic Endoscopy (QUAIDE) Explanation and Checklist was to develop recommendations for standardised design and reporting of preclinical AI studies in GI endoscopy. The recommendations were developed based on a formal consensus approach with an international multidisciplinary panel of 32 experts among endoscopists and computer scientists. The Delphi methodology was employed to achieve consensus on statements, with a predetermined threshold of 80% agreement. A maximum three rounds of voting were permitted. Consensus was reached on 18 key recommendations, covering 6 key domains: data acquisition and annotation (6 statements), outcome reporting (3 statements), experimental setup and algorithm architecture (4 statements) and result presentation and interpretation (5 statements). QUAIDE provides recommendations on how to properly design (1. Methods, statements 1–14), present results (2. Results, statements 15–16) and integrate and interpret the obtained results (3. Discussion, statements 17–18). The QUAIDE framework offers practical guidance for authors, readers, editors and reviewers involved in AI preclinical studies in GI endoscopy, aiming at improving design and reporting, thereby promoting research standardisation and accelerating the translation of AI innovations into clinical practice.

14 June 2024 in Gut
Verified
Journal Article
Open access
PDF file
PSPieter Sinonquel
Pieter Sinonquel
TETom Eelbode
Tom Eelbode
OPOliver Pech
Oliver Pech
DWDominiek De Wulf
Dominiek De Wulf
PDPieter Dewint
Pieter Dewint
RBRaf Bisschops
Raf Bisschops
Background and aim Randomised trials show improved polyp detection with computer-aided detection (CADe), mostly of small lesions. However, operator and selection bias may affect CADe’s true benefit. Clinical outcomes of increased detection have not yet been fully elucidated. Methods In this multicentre trial, CADe combining convolutional and recurrent neural networks was used for polyp detection. Blinded endoscopists were monitored in real time by a second observer with CADe access. CADe detections prompted reinspection. Adenoma detection rates (ADR) and polyp detection rates were measured prestudy and poststudy. Histological assessments were done by independent histopathologists. The primary outcome compared polyp detection between endoscopists and CADe. Results In 946 patients (51.9% male, mean age 64), a total of 2141 polyps were identified, including 989 adenomas. CADe was not superior to human polyp detection (sensitivity 94.6% vs 96.0%) but outperformed them when restricted to adenomas. Unblinding led to an additional yield of 86 true positive polyp detections (1.1% ADR increase per patient; 73.8% were <5 mm). CADe also increased non-neoplastic polyp detection by an absolute value of 4.9% of the cases (1.8% increase of entire polyp load). Procedure time increased with 6.6±6.5 min (+42.6%). In 22/946 patients, the additional detection of adenomas changed surveillance intervals (2.3%), mostly by increasing the number of small adenomas beyond the cut-off. Conclusion Even if CADe appears to be slightly more sensitive than human endoscopists, the additional gain in ADR was minimal and follow-up intervals rarely changed. Additional inspection of non-neoplastic lesions was increased, adding to the inspection and/or polypectomy workload.

1 June 2019 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
TETom Eelbode
Tom Eelbode
IDIngrid Demedts
Ingrid Demedts
RBRaf Bisschops
Raf Bisschops
PRPhilip Roelandt
Philip Roelandt
CHCesare Hassan
Cesare Hassan
FMFrederik Maes
Frederik Maes