Wen Qin

Wen Qin

Auto-generated profile, based on publicly available information

Wen Qin

Department of Ultrasonography, Xiangyang Central Hospital, Affiliated Hospital of Hubei University of Arts and Science, Xiangyang 441020, Hubei, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2022 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Closed access
GLGuoqing Liu
Guoqing Liu
MGMeiling Gao
Meiling Gao
YHYang Hu
Yang Hu
BWBangjun Wang
Bangjun Wang
YLYunhua Lin
Yunhua Lin
WQWen Qin
Wen Qin

27 October 2023 in European Journal of Horticultural Science
Verified
Journal Article
Open access
CZChao Zhang
Chao Zhang
QWQin Wen
Qin Wen
FYFang Yumei
Fang Yumei
GLGuo Lina
Guo Lina
WLWei Linjuan
Wei Linjuan

1 February 2023 in Wuhan University Journal of Natural Sciences
Verified
Journal Article
Open access
PDF file
WQWen Qin
Wen Qin
SYShengxing Yuan
Shengxing Yuan
XWXingyue Wang
Xingyue Wang
This study aims to compare the differences in sampling satisfaction rates between 5 mL syringe and 22G percutaneous transhepatic cholangiography (PTC) needles in fine-needle aspiration (FNA) to provide economical and reasonable needle selection. From January 2021 to March 2022, 187 patients with thyroid nodules (a total of 200 nodules) who underwent ultrasound-guided FNA were punctured using 22G PTC and 5 mL syringe needles once for each nodule, and the sample was sent for pathological examination. The sample satisfaction rate of the two methods was statistically analyzed, and factors affecting the sample satisfaction rate were determined. Results demonstrated that the overall sample satisfaction rates of 5 mL syringes and 22G PTC needles were 83% and 85% (P>0.05), respectively. The satisfaction rates of the two specimens were 92.6% and 91.1% (P> 0.05) among 136 nodules with poor blood supply. For 64 nodules with rich blood supply, the satisfaction rate of both specimens was significantly lower than that of the nodule with poor blood supply (P <0.05), and that of the 5 mL syringe needle was significantly lower than that of the latter (62.5% vs. 71.8%, P <0.05). The results suggest that satisfactory sampling results can be obtained using either a 5 mL syringe or 22G PTC needles. The 22G PTC needle is more likely to yield FNA results if the nodule is rich in blood supply.