Karim Makki

Karim Makki

Auto-generated profile, based on publicly available information

Karim Makki

EnCoV, Institut Pascal, UMR6602 CNRS/UCA, Clermont-Ferrand, France

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
KMKarim Makki
Karim Makki
KCKilian Chandelon
Kilian Chandelon
ABAdrien Bartoli
Adrien Bartoli

24 February 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
KMKarim Makki
Karim Makki
ABAmine Bohi
Amine Bohi
AOAugustin C. Ogier
Augustin C. Ogier
MBMarc Emmanuel Bellemare
Marc Emmanuel Bellemare

16 September 2021 in IEEE Access
Verified
Journal Article
Open access
KMKarim Makki
Karim Makki
DOURAIED BEN SALEMDOURAIED BEN SALEM
DOURAIED BEN SALEM
BABoulbaba Ben Amor
Boulbaba Ben Amor
Principal and Gaussian curvatures are a commonly used intrinsic metrics for geometric morphometrics analysis: to assess morphometric changes in brain geometry (developmental neuroimaging studies), to quantify shape deformation (organ motion assessment), or to analyze shape variability across subjects (in musculoskeletal studies: statistical shape analysis of bones). However, most of existing algorithms for estimating curvatures act on explicit surfaces (triangle meshes), making them time consuming and sensitive to parameterization and neighborhood size. In this paper, we present a suite of fast and parameterization-free algorithms to estimate second order morphometric parameters given an implicit representation for the surface and without any loss of accuracy. We first show results for direct comparisons of our algorithms with a suite of popular algorithms for estimating curvatures of surfaces represented by triangular meshes. In the context of brain imaging, methods were validated against developmental brain MRI data in which surface based analysis has very often failed. We also provided a modified version of the algorithm that can deal with a Freesurfer output surface mesh, and which was evaluated using an adult brain with more complicated folding patterns. Our algorithm provided a more realistic measures of intrinsic curvature for the white matter (mostly ranged between -0.07 and 0.07 mm-2) which confirms its robustness. As compared to mesh-based algorithms, our algorithm reduces computation times from a few minutes to only a few seconds, showing a decrease by a factor of up to 7.

26 May 2022 in Acta Radiologica
Verified
Journal Article
Closed access
MGMarc Garetier
Marc Garetier
JRJean Rousset
Jean Rousset
KMKarim Makki
Karim Makki
SBSylvain Brochard
Sylvain Brochard
FRFrançois Rousseau
François Rousseau
BBBhushan Borotikar
Bhushan Borotikar
Background: Real-time sequences allow functional evaluation of various joint structures during a continuous motion and help understand the pathomechanics of underlying musculoskeletal diseases. Purpose: To assess and compare the image quality of the two most frequently used real-time sequences for joint dynamic magnetic resonance imaging (MRI), acquired during finger and ankle joint motion. Material and Methods: A real-time dynamic acquisition protocol, including radiofrequency (RF)-spoiled and balanced steady-state free precession (bSSFP) sequences, optimized for temporal resolution with similar spatial resolution, was performed using a 3.0-T MRI scanner on 10 fingers and 12 ankles from healthy individuals during active motion. Image quality criteria were evaluated on each time frame and compared between these two sequences. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined and compared from regions of interest placed on cortical bone, tendon, fat, and muscle. Visualization of anatomical structures and overall image quality appreciation were rated by two radiologists using a 0–10 grading scale. Results: Mean CNR was significantly higher with bSSFP sequence compared to RF-spoiled sequence. The grading score was in the range of 5–9.3 and was significantly higher with RF-spoiled sequence for bone and joint evaluation and overall image appreciation on the two joints. The standard deviation for SNR, CNR, and grading score during motion was smaller with RF-spoiled sequence for both the joints. The inter-reader reliability was excellent (>0.75) for evaluating anatomical structures in both sequences. Conclusion: A RF-spoiled real-time sequence is recommended for the in vivo clinical evaluation of distal joints on a 3.0-T MRI scanner.

3 April 2026
Verified
Thesis
Closed access
KMKarim Makki
Karim Makki
Développement de l'IRM dynamique pour l'étude de l'appareil musculo-squelettique en mouvement: La paralysie cérébrale (PC) est la première cause de l’handicap moteur de l’enfant en France (2 naissances pour 1000). Il s’agit d’une pathologie causée par des atteintes non progressives survenues lors du développement du cerveau chez le foetus ou le nourrisson. L’équin de la cheville est la déformation musculo-squelettique la plus fréquente chez les enfants atteints par la PC. Malgré des thérapies médico-chirurgicales multiples, le taux de récidive post-opératoire demeure très élevé(48%). Une des principales raisons des échecs des thérapies est le manque de connaissance de la biomécanique articulaire et musculaire. Les techniques d’imagerie en IRM dynamique permettent aujourd’hui d’explorer l’appareil musculo-squelettique au cours du mouvement dans les 3 dimensions de l’espace avec une grande précision (<1mm). Cependant, ces techniques viennent avec leur propre liste de problèmes tels que la résolution réduite, l’anisotropie et les artefacts de mouvement. Dans cette thèse, nous abordons ces problèmes en combinant l’information spatiale de l’IRM conventionnel avec l’information temporelle fournie par les séquences IRM dynamique. Nous avons réussi à atteindre l’objectif principal de ces travaux de recherche en développant des algorithmes robustes combinant des aspects informatiques et mathématiques (dont le recalage d’images basé sur l’intensité était le facteur clé) qui nous ont permis de reconstruire les mouvements articulaires et donc d’établir une analyse biomécanique de la cheville en plus de la reconstruction spatio-temporelle de la séquence dynamique en utilisant une approche logeuclidienne. Les algorithmes proposés ont été appliqués sur la base de données actuellement disponible (contenant 6 sujets normaux) et devraient être également appliqués sur une base plus large contenant des sujets pathologiques de la même tranche d’âges afin de comparer les deux populations et de caractériser la pathologie.

17 February 2022 in arXiv
Verified
Preprint
Open access
PDF file
KMKarim Makki
Karim Makki
JLJean François Lecomte
Jean François Lecomte
LFLukas Fuchs
Lukas Fuchs
SSSylvie Schueller
Sylvie Schueller
EMEtienne Mémin
Etienne Mémin
Image-based computational fluid dynamics have long played an important role in leveraging knowledge and understanding of several physical phenomena. In particular, probabilistic computational methods have opened the way to modelling the complex dynamics of systems in purely random turbulent motion. In the field of structural geology, a better understanding of the deformation and stress state both within the salt and the surrounding rocks is of great interest to characterize all kinds of subsurface long-terms energy-storage systems. The objective of this research is to determine the non-linear deformation of the salt boundary over time using a parallelized, stochastic filtering approach from x-ray computed tomography (CT) image time series depicting the evolution of salt structures triggered by gravity and under differential loading. This work represents a first step towards bringing together physical modeling and advanced stochastic image processing methods where model uncertainty is taken into account.