Eric. C. Frey

Eric. C. Frey

Auto-generated profile, based on publicly available information

Eric. C. Frey

Department of Electrical and Computer Engineering Johns Hopkins University Baltimore MD USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2022 in Medical Image Analysis
Verified
Journal Article
Closed access
JCJunyu Chen
Junyu Chen
EFEric C. Frey
Eric C. Frey
YHYufan He
Yufan He
WSWilliam P. Segars
William P. Segars
YLYe Li
Ye Li
YDYong Du
Yong Du

24 February 2011 in Medical Physics
Verified
Journal Article
Closed access
XWXiaolan Wang
Xiaolan Wang
DMDirk Meier
Dirk Meier
KTKatsuyuki Taguchi
Katsuyuki Taguchi
DWDouglas J. Wagenaar
Douglas J. Wagenaar
BPBradley E. Patt
Bradley E. Patt
EFEric C. Frey
Eric C. Frey

1 September 2002 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
EFE.C. Frey
E.C. Frey
KGK.L. Gilland
K.L. Gilland
BTB.M.W. Tsui
B.M.W. Tsui
In this paper, we apply the channelized Hotelling observer (CHO) using a defect detection task to the optimization and evaluation of three-dimensional iterative reconstruction-based compensation methods for myocardial perfusion single-photon emission computed tomography (SPECT). We used a population of 24 mathematical cardiac-torso phantoms that realistically model the activity and attenuation distribution in three classes of patients: females, and males with flat diaphragms and raised diaphragms. Projection data were generated and subsequently reconstructed using methods based on the ordered subsets-expectation maximization (OSEM) algorithm. The methods evaluated included compensation for attenuation, detector response blurring, and scatter in various combinations. We applied the CHO to optimize the number of iterations for OSEM and the cutoff frequency and order of a three-dimensional postreconstruction Butterworth filter. Using the optimal parameters, we then compared the compensation methods. The index of comparison in these studies was the area under the receiver operating characteristics curve (AUC) for the CHO. We found that attenuation compensation with either detector response or scatter compensation gave statistically significant increases in the AUC compared to attenuation compensation alone. The greatest increase in the AUC occurred when all three compensations were applied. These results indicate that compensation for detector response and scatter, in addition to attenuation compensation, will improve defect detectability in myocardial SPECT images.

5 April 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
XWX Wang
X Wang
DMD Meier
D Meier
SMS Mikkelsen
S Mikkelsen
GMG E Maehlum
G E Maehlum
DWD J Wagenaar
D J Wagenaar
EFE C Frey
E C Frey
The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts. Each detector pixel can simultaneously count x-ray photons above six energy thresholds, providing the capability for energy-selective x-ray imaging. We tested the spectroscopic performance of the system using polychromatic x-ray radiation and various filtering materials with K-absorption edges. Tomographic images were then acquired of a cylindrical PMMA phantom containing holes filled with various materials. Results were also compared with those acquired using an intensity-integrating x-ray detector and single-energy (i.e. non-energy-selective) CT. This paper describes the functionality and performance of the system, and presents preliminary spectroscopic and tomographic results. The spectroscopic experiments showed that the energy-resolved photon-counting detector was capable of measuring energy spectra from polychromatic sources like a standard x-ray tube, and resolving absorption edges present in the energy range used for imaging. However, the spectral quality was degraded by spectral distortions resulting from degrading factors, including finite energy resolution and charge sharing. We developed a simple charge-sharing model to reproduce these distortions. The tomographic experiments showed that the availability of multiple energy thresholds in the photon-counting detector allowed us to simultaneously measure target-to-background contrasts in different energy ranges. Compared with single-energy CT with an integrating detector, this feature was especially useful to improve differentiation of materials with different attenuation coefficient energy dependences.

30 September 2016 in Medical Physics
Verified
Journal Article
Closed access
PDF file
JYJianting Yue
Jianting Yue
TMThibault Mauxion
Thibault Mauxion
DRDiane K. Reyes
Diane K. Reyes
MLMartin A. Lodge
Martin A. Lodge
RHRobert F. Hobbs
Robert F. Hobbs
EFEric C. Frey
Eric C. Frey

27 January 2009 in Medical Physics
Verified
Journal Article
Closed access
BHBin He
Bin He
YDYong Du
Yong Du
WSW. Paul Segars
W. Paul Segars
RWRichard L. Wahl
Richard L. Wahl
GSGeorge Sgouros
George Sgouros
EFEric C. Frey
Eric C. Frey