1 November 2018 in Engineering Geology
1 June 2018 in Soils and Foundations
The vacuum preloading method has been wisely chosen among many ground-improvement methods considering the time limit of many projects and the characteristics of reclaimed soil. However, the loss in vacuum with soil depth, the clogging around prefabricated vertical drains (PVDs), and the deteriorative consolidation of the deep soil layer, among other factors, create a large challenge to vacuum preloading for dredged marine clay fill. Thus, this study proposes a two-stage vacuum preloading method and focuses on its feasibility and effectiveness. Contrasting laboratory tests are performed in two identical experimental tanks with dredged marine clay fill from the Wenzhou land reclamation site in China. In one tank, the one-stage vacuum preloading method is used to serve as a baseline for this study. In the other tank, use of the two-stage vacuum preloading method is proposed for consolidation; it comprises two stages. In the first stage, the dredged marine clay fill is conditioned by vacuum preloading using half of the PVDs, where the dissipation of the excess pore water pressure tends to be steady. In the second stage, vacuum preloading is activated using all the PVDs. The results show that a better consolidation effect is achieved with the proposed method in terms of the settlement, vacuum pressure, pore water pressure, water content, vane shear strength, and soil particle microstructure after soil consolidation. © 2018
1 February 2017 in Geosynthetics International
Two representative laboratory tests, using vacuum preloading alone and vacuum preloading combined with variable-spacing electro-osmosis (EO), were performed on dredged marine clay slurry used for tideland reclamation. This combined method consists of the following three stages: vacuum preloading alone, vacuum preloading in combination with large spacing EO, and vacuum preloading in combination with small spacing EO. This study focused on the feasibility and effectiveness of variable-spacing EO. The results showed that better consolidation was achieved using the combined method in terms of water content, dry density, degree of saturation, Atterberg limits, discharge of water, vane shear strength, current, and excess pore water pressure. Energy consumption for consolidation of the large spacing EO stage was less than for the small-spacing EO stage.
7 February 2019 in Marine Georesources & Geotechnology
To achieve the rapid dewatering of dredged sludge, the flocculation–vacuum-preloading method was tested indoors. In this study, the optimal mixing ratio of six flocculants was determined through the settling column test, and then the proposed method was tested. The water drainage and settlement were monitored during the test, while the soil moisture content and shear strength were measured after the test. The results show that all the flocculants had an optimal mixing ratio, and the addition of 0.8% FeCl3 or 0.08% anionic polyacrylamide (APAM) in the sludge can better accelerate solid–liquid separation of the sludge. After the test, the water content in the sludge decreased from 140% to 60%. Compared with general vacuum preloading, the use of the proposed method increased the water drainage by 46.5% and 56.8% and decreased the soil volumes by 60.5% and 82.4% for FeCl3 and APAM, respectively. Moreover, the corresponding shear strength was increased from 10 to 14 and 17 kPa. In addition, the use of APAM increased the solidification rate of heavy metals in the sludge to more than 80%, effectively inhibiting the migration of heavy metals.
10 February 2017 in Marine Georesources & Geotechnology
The electroosmosis method is regarded especially suitable for the disposal of dredged clay sediment, but its excessive power consumption and electrode corrosion has limited its widespread application. Thus, intermittent current and polarity reversal are applied to offset its drawbacks. This study aims to examine the consolidation effect and internal relationship between the two approaches and optimize their time settings. Laboratory tests were performed with the same intermittent ratio and different reversal ratios. The test results demonstrated that intermittent current with comparatively greater intermittent times and a higher reversal ratio achieved a better drainage effect during the electroosmosis process and soil uniformity after test and the drainage in the reverse direction was lesser than that in the forward direction. The drainage effect during the power-off mode for 1 h was equivalent to that in the reverse electrifying mode for 0.2–0.25 h. Sharp increases in the current were induced by each intermittent current and polarity reversal. Although the polarity reversal approach improved the drainage effect, it partly increased the energy consumption. Compared with the intermittent current approach, reducing the reverse electrifying period to improve soil consolidation is feasible for application to engineering practice.
8 February 2019 in Marine Georesources & Geotechnology
Air booster vacuum preloading method is a useful method for strengthening dredged slurry. Though this method is improved effectively with the rapidly developed technology, the problem of inadequate reinforcement in deep layers of soil is still in existence. In view of the fact that the pressurizing system can effectively enhance the reinforcement effect. Therefore, this paper discusses the reinforcement effect of a new pressurizing system that put the booster pipeline at the bottom of soil. Meanwhile, another problem is found that the booster pipeline type was single at present, the action effect of different kind of booster pipeline is still uncertain. In this paper, laboratory experiments are performed to investigate the influence of two kinds of pressurization position and two types of booster pipeline on the treatment of five dredged slurry samples. The test results showed that though the vertical pressurizing system can be good to reinforce the middle soil layers, but the bottom pressurizing system can make the whole soil layer more homogeneous. Furthermore, the difference of the two kinds of booster pipeline on the reinforcement effect of soil is not significant. These results provide good guidance for practical application of air booster vacuum preloading in land reclamation project.