Eduardo B. Mariottoni

Eduardo B. Mariottoni

Auto-generated profile, based on publicly available information

Eduardo B. Mariottoni

Department of Ophthalmology, Federal University of Sao Paulo, Sao Paulo, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in JAMA Ophthalmology
Verified
Journal Article
Open access
PDF file
ATAtalie C. Thompson
Atalie C. Thompson
AJAlessandro A. Jammal
Alessandro A. Jammal
SBSamuel I. Berchuck
Samuel I. Berchuck
EMEduardo B. Mariottoni
Eduardo B. Mariottoni
FMFelipe A Medeiros
Felipe A Medeiros
In clinical practice, glaucoma is usually diagnosed by a combined analysis of several clinical parameters, including risk factors, such as age and intraocular pressure; tests for evaluation of structural damage to the optic nerve; and visual function assessment with perimetry. Among tests for structural evaluation,1,2 spectral-domain optical coherence tomography (SD-OCT) is the most commonly used one, providing objective quantification of damage to the optic nerve head and retinal nerve fiber layer (RNFL).3 To provide quantitative RNFL thickness measurements, conventional SD-OCT software applies segmentation algorithms to delineate the RNFL and extract its thickness. Although SD-OCT RNFL thickness measurements can be generally accurate for diagnosing glaucoma,3,4 they may fail in the presence of segmentation errors.5,6 Such errors have been reported in 20% to more than 40% of scans5 and significantly affect the diagnostic accuracy of SD-OCT in glaucoma.5,6

1 March 2020 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
AJAlessandro A. Jammal
Alessandro A. Jammal
ATAtalie C. Thompson
Atalie C. Thompson
EMEduardo B. Mariottoni
Eduardo B. Mariottoni
SBSamuel I. Berchuck
Samuel I. Berchuck
CUCarla N. Urata
Carla N. Urata
FMFelipe A Medeiros
Felipe A Medeiros

28 January 2020 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
EMEduardo B. Mariottoni
Eduardo B. Mariottoni
SDShounak Datta
Shounak Datta
DDDavid Dov
David Dov
AJAlessandro A. Jammal
Alessandro A. Jammal
SBSamuel I. Berchuck
Samuel I. Berchuck
FMFelipe A Medeiros
Felipe A Medeiros
Purpose: To develop an artificial intelligence (AI)–based structure-function (SF) map relating retinal nerve fiber layer (RNFL) damage on spectral domain optical coherence tomography (SDOCT) to functional loss on standard automated perimetry (SAP). Methods: The study included 26,499 pairs of SAP and SDOCT from 15,173 eyes of 8878 patients with glaucoma or suspected of having the disease extracted from the Duke Glaucoma Registry. The data set was randomly divided at the patient level in training and test sets. A convolutional neural network (CNN) was initially trained and validated to predict the 52 sensitivity threshold points of the 24-2 SAP from the 768 RNFL thickness points of the SDOCT peripapillary scan. Simulated localized RNFL defects of varied locations and depths were created by modifying the normal average peripapillary RNFL profile. The simulated profiles were then fed to the previously trained CNN, and the topographic SF relationships between structural defects and SAP functional losses were investigated. Results: The CNN predictions had an average correlation coefficient of 0.60 (P < 0.001) with the measured values from SAP and a mean absolute error of 4.25 dB. Simulated RNFL defects led to well-defined arcuate or paracentral visual field losses in the opposite hemifield, which varied according to the location and depth of the simulations. Conclusions: A CNN was capable of predicting SAP sensitivity thresholds from SDOCT RNFL thickness measurements and generate an SF map from simulated defects. Translational Relevance: AI-based SF map improves the understanding of how SDOCT losses translate into detectable SAP damage.

7 January 2021 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
TLTerry Lee
Terry Lee
AJAlessandro Jammal
Alessandro Jammal
EMEduardo B. Mariottoni
Eduardo B. Mariottoni
FMFelipe A Medeiros
Felipe A Medeiros

15 January 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EMEduardo B. Mariottoni
Eduardo B. Mariottoni
AJAlessandro Jammal
Alessandro Jammal
CUCarla N. Urata
Carla N. Urata
SBSamuel I. Berchuck
Samuel I. Berchuck
ATAtalie C. Thompson
Atalie C. Thompson
FMFelipe A Medeiros
Felipe A Medeiros
This study describes a segmentation-free deep learning (DL) algorithm for measuring retinal nerve fibre layer (RNFL) thickness on spectral-domain optical coherence tomography (SDOCT). The study included 25,285 B-scans from 1,338 eyes of 706 subjects. Training was done to predict RNFL thickness from raw unsegmented scans using conventional RNFL thickness measurements from good quality images as targets, forcing the DL algorithm to learn its own representation of RNFL. The algorithm was tested in three different sets: (1) images without segmentation errors or artefacts, (2) low-quality images with segmentation errors, and (3) images with other artefacts. In test set 1, segmentation-free RNFL predictions were highly correlated with conventional RNFL thickness (r = 0.983, P < 0.001). In test set 2, segmentation-free predictions had higher correlation with the best available estimate (tests with good quality taken in the same date) compared to those from the conventional algorithm (r = 0.972 vs. r = 0.829, respectively; P < 0.001). Segmentation-free predictions were also better in test set 3 (r = 0.940 vs. r = 0.640, P < 0.001). In conclusion, a novel segmentation-free algorithm to extract RNFL thickness performed similarly to the conventional method in good quality images and better in images with errors or other artefacts.

8 July 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AJAlessandro Jammal
Alessandro Jammal
ATAtalie C. Thompson
Atalie C. Thompson
NONara G. Ogata
Nara G. Ogata
EMEduardo B. Mariottoni
Eduardo B. Mariottoni
CUCarla N. Urata
Carla N. Urata
FMFelipe A Medeiros
Felipe A Medeiros
In this study we developed a deep learning (DL) algorithm that detects errors in retinal never fibre layer (RNFL) segmentation on spectral-domain optical coherence tomography (SDOCT) B-scans using human grades as the reference standard. A dataset of 25,250 SDOCT B-scans reviewed for segmentation errors by human graders was randomly divided into validation plus training (50%) and test (50%) sets. The performance of the DL algorithm was evaluated in the test sample by outputting a probability of having a segmentation error for each B-scan. The ability of the algorithm to detect segmentation errors was evaluated with the area under the receiver operating characteristic (ROC) curve. Mean DL probabilities of segmentation error in the test sample were 0.90 ± 0.17 vs. 0.12 ± 0.22 (P < 0.001) for scans with and without segmentation errors, respectively. The DL algorithm had an area under the ROC curve of 0.979 (95% CI: 0.974 to 0.984) and an overall accuracy of 92.4%. For the B-scans with severe segmentation errors in the test sample, the DL algorithm was 98.9% sensitive. This algorithm can help clinicians and researchers review images for artifacts in SDOCT tests in a timely manner and avoid inaccurate diagnostic interpretations.