Júlia Adorno Barbosa

Júlia Adorno Barbosa

Auto-generated profile, based on publicly available information

Júlia Adorno Barbosa

Brazilian Nanotechnology National Laboratory, Brazilian Center for Research in Energy and Materials, Campinas, São Paulo 13083-970, Brazil

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
JBJúlia A. Barbosa
Júlia A. Barbosa
VFVitoria M. S. Freitas
Vitoria M. S. Freitas
LVLourenço H. B. Vidotto
Lourenço H. B. Vidotto
GSGabriel R. Schleder
Gabriel R. Schleder
RORicardo A. G. de Oliveira
Ricardo A. G. de Oliveira
RLRenato S. Lima
Renato S. Lima

15 July 2020 in Chemical Engineering Communications
Verified
Journal Article
Closed access
JBJúlia Adorno Barbosa
Júlia Adorno Barbosa
GLGeórgia Labuto
Geórgia Labuto
ECElma Neide Vasconcelos Martins Carrilho
Elma Neide Vasconcelos Martins Carrilho
A new approach on the sorption of aconitic and citric acids by activated carbon (AC) after nanomodification with Fe3O4 (AC-MNP) is proposed in batch procedures and as SPE (Solid Phase Extraction) cartridges for the treatment of complex samples prior to HPLC analysis. AC and AC-MNP were characterized by XRD, SEM, EDS, and FTIR. The mean crystallite size of AC-MNP and MNP were 19.16 and 10.70 nm, respectively, and FTIR bands characteristics of C = C, C–O, OH, and Fe–O were identified. Amaranth red dye sorption by AC and AC-MNP was evaluated and indicated that the surface charge of AC and AC-MNP is predominantly cationic. Experimental AC-MNP sorption capacity (SC exp) for aconitic and citric acids were 52.44 mg/g and 36.88 mg/g, respectively, and these analytes were determined by high performance liquid chromatography (HPLC). Nanomodified activated carbon (AC-MNP) cartridges were prepared to be used as SPE and compared with commercially available C18. The retention capacity of AC-MNP was 75% higher than that of C18, resulting, respectively, in 29.31 mg/g and 30.06 mg/g AC-MNP for aconitic, and 7.81 mg/g and 8.44 mg/g C18 for citric acids. Among the isotherms models used, Freundlich and Langmuir were better adjusted to aconitic and citric acid, respectively. The AC-MNP sorbent seems to be an efficient low-cost alternative to the commercially C18 cartridges most commonly used for sample pretreatment prior to organic acid determination in complex samples analysis by HPLC.