Dip Ghosh

Dip Ghosh

Auto-generated profile, based on publicly available information

Dip Ghosh

Department of Animal Science, Faculty of Animal Husbandry Bangladesh Agricultural University Mymensigh Bangladesh

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2024 in Meat Research
Verified
Journal Article
Open access
PDF file
TST Sarker
T Sarker
RDRa Deen
Ra Deen
DGDip Ghosh
Dip Ghosh
Nayeem MiaNayeem Mia
Nayeem Mia
MRMm Rahman
Mm Rahman
MHMa Hashem
Ma Hashem
Consumers' increasing demand for high-quality and safe meat products has led the food industry to explore advanced analytical techniques, such as artificial intelligence and nearinfrared reflectance spectroscopy to assess and monitor the quality and safety of meat. The quality and safety of meat products have become increasingly important considerations for consumers, driven by concerns over health implications and the need for transparency in the meat supply chain. The meat industry faces increasing demands from consumers for higher quality and safer products, driven by concerns over food-borne illnesses and the nutritional value of meat. Addressing these growing consumer expectations has become a priority, prompting researchers to actively investigate the potential of innovative nondestructive techniques, including near-infrared spectroscopy and others in combination with advanced data analysis methodologies to enable rapid, objective, and environmentally-friendly assessment of diverse meat quality and safety attributes. This review examines the current state of research on the application of these technologies in the meat industry. Additionally, it explores the integration of artificial intelligence algorithms with near-infrared spectroscopy data to enhance the accuracy and reliability of meat quality prediction and authentication.


31 August 2024 in Meat Research
Verified
Journal Article
Closed access
PDF file
RSRr Sarkar
Rr Sarkar
RDRa Deen
Ra Deen
DGDip Ghosh
Dip Ghosh
TST Sarker
T Sarker
SAS Akther
S Akther
MHMa Hashem
Ma Hashem
This study investigates the effectiveness of two methods— the standard bag method and filter paper wetness (FPW) method—in assessing drip loss (DL) and their potential application in broiler chicken meat quality classification. The standard bag method measures drip loss by suspending meat samples in plastic bags to capture expelled fluids over a set period, whereas the filter paper wetness method involves pressing the meat onto filter paper to evaluate the amount of moisture released. In this study, samples from broiler chickens were assessed using both methods, and the resulting drip loss values were compared against meat quality categories such as PSE (pale, soft, exudative), normal, and DFD (dark, firm, dry) classifications. Both methods are widely used for evaluating drip loss, but their reliability and correlation with meat quality classification have not been extensively compared. Thirty broiler chickens were selected, and their breast meat was evaluated to understand the relationships between water-holding capacity (WHC), pH, lightness (L*), and other meat quality attributes. To facilitate this analysis, samples were categorized into three meat quality classes: Pale, Soft, and Exudative (PSE); Normal; and Dark, Firm, and Dry (DFD). The study aimed to assess the correlation between WHC and other evaluated characteristics and employed linear regression analyses to examine FPW and WHC as functions of 24-hour drip loss. Results showed that 5% DL corresponded to 64.77 mg water in FPW and was equivalent to 93.61% in WHC, establishing benchmarks for broiler meat quality classification. Using these 5% DL equivalents (93.61% WHC), along with immediate pH and lightness criteria, samples were accurately categorized across all quality classes. The high R² values (R 2 = 0.83, and P < 0.0001.) observed between WHC (%) and DL (%), as well as between FPW (mg) and DL (%) (R 2 = 0.82, and P < 0.0001.), underscored the reliability of these assessment methods. This study supports the efficacy of using WHC and FPW in the classification of broiler chicken meat quality, providing a reliable and quantifiable approach to meat quality evaluation. These findings have significant implications for meat industry practices, enabling precise classification and enhancing quality control in poultry meat production.

28 February 2025 in Meat Research
Verified
Journal Article
Open access
PDF file
RKR Khatun
R Khatun
IAI Akter
I Akter
RDRa Deen
Ra Deen
DGDip Ghosh
Dip Ghosh
MHMa Hashem
Ma Hashem
This study investigated the differences in sensory and physicochemical attributes between pre- and post-rigor broiler meat. Five live broilers were collected from the K.R. Market of BAU, Mymensingh, and meat samples were analyzed immediately after slaughter and deboning for pre-rigor conditions, while post-rigor samples were analyzed after 24-hour chilling at 4°C. A 2×2 factorial experiment in a completely randomized design (CRD) was employed for data analysis. Sensory parameters, including color, flavor, texture, tenderness, and overall acceptability, were assessed, along with physicochemical properties such as pH, cooking loss, drip loss, water-holding capacity, and instrumental color measurements (CIE L*, CIE a*, CIE b*, hue angle, and saturation index). The results revealed that sensory attributes of both breast and thigh meat improved significantly (p<0.05) after post-rigor aging, indicating better flavor, tenderness, and overall acceptability. Physicochemical analysis showed a significant decrease (p<0.05) in pH for both breast and thigh meat, while instrumental color analysis indicated that post-rigor breast meat had significantly higher CIE L* (lightness) and hue angle but lower CIE a* (redness). These findings highlight that post-rigor aging significantly enhances both sensory and physicochemical qualities, making it the more preferable and acceptable treatment. This study provides valuable insights for optimizing meat processing methods to improve consumer satisfaction and meat quality.

14 September 2026 in Efood
Verified
Journal Article
Open access
PDF file
DGDip Ghosh
Dip Ghosh
RDRaad Al Deen
Raad Al Deen
MHMd. Abul Hashem
Md. Abul Hashem
Ensuring the authenticity of high‐value indigenous meats such as cattle ( Bos indicus ) and water buffalo ( Bubalus bubalis ) has gained heightened attention as a result of frequent adulteration in global supply chains. This study established a rapid, non‐destructive authentication framework comparing physicochemical profiling and portable near‐infrared spectroscopy (NIRS) combined with machine learning (ML). Forty longissimus thoracis et lumborum samples ( n = 20/species) were analyzed for pH, color ( L *, a *, b *), water‐holding capacity, drip loss, cooking loss, and shear force. A total of 4000 NIR spectra (700–1100 nm) were acquired using a handheld spectrometer. Buffalo samples exhibited significantly higher shear force (77.82 N), cooking loss (32.56%), and redness ( a * = 20.92) than cattle ( p < 0.001). NIRS analysis revealed distinct absorbance peaks in buffalo in the O–H (900–980 nm) and C─ H/N─H (750–850, 1060–1088 nm) regions. ML models, including XGBoost and a 1D convolutional neural network, achieved 98.12% and 98.4% accuracy, respectively. SHAP analysis identified 1075.30 nm as a key differentiating wavelength associated with protein and moisture. However, further validation using larger and more diverse sample sets, external test datasets, and intentional adulteration scenarios is required before confirming its broader applicability for routine authentication and fraud detection.

5 November 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
RDRaad Al Deen
Raad Al Deen
DGDip Ghosh
Dip Ghosh
MHMd. Abul Hashem
Md. Abul Hashem
The misrepresentation of frozen-thawed meat as fresh constitutes economic fraud that can result in financial losses and erode consumer confidence in meat products. Portable near-infrared (NIR) spectroscopy could serve as a process analytical tool for on-site screening if its predictive performance can be maintained across previously unseen animals. This study developed a leakage-controlled, explainable and reliability-calibrated workflow to screen chevon (goat meat) for freeze-thaw history with a handheld short-wave NIR spectrometer (710 to 1027 nm). Longissimus dorsi samples from 400 Black Bengal goats were scanned fresh and after vacuum-packed storage at −18 °C for 60 d and thawing. All data-driven steps used 320 training animals, nested animal-grouped cross-validation estimated performance and 80 unseen animals formed an independent test set. Freeze-thaw increased absorbance by 0.137 AU on average (median paired dz = 1.06) and changed spectral shape regionally. A support vector machine selected by the one-standard-error rule reached a nested accuracy of 0.865 ± 0.022 and a test accuracy of 0.888 (95% CI 0.831 to 0.931, AUC 0.961), equivalent to linear models. Discrimination relied mainly on the broadband absorbance level. At 95% confidence, class-conditional conformal prediction classified 56.2% of test samples with 98.9% accuracy and referred the remainder. Since the two states were scanned on different days, same-session validation is required before deployment. These results highlight the potential of handheld NIR spectroscopy for reliable on-site screening of freeze-thaw history in chevon.