Alexandre Mendonça Munhoz

Alexandre Mendonça Munhoz

Auto-generated profile, based on publicly available information

Alexandre Mendonça Munhoz

Coordinator of the Plastic Surgery Department, Hospital Moriah , São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2019 in Aesthetic Plastic Surgery
Verified
Journal Article
Closed access
PDF file
IJIvan Maluf Junior
Ivan Maluf Junior
RGRuth Maria Graf
Ruth Maria Graf
AAAdriana Sayuri Kurogi Ascenço
Adriana Sayuri Kurogi Ascenço
WIWillian Itikawa
Willian Itikawa
PBPriscilla Balbinot
Priscilla Balbinot
RFRenato da Silva Freitas
Renato da Silva Freitas

1 September 2020 in Aesthetic Surgery Journal
Verified
Journal Article
Closed access
PDF file
EAEduardo Rocha Arruda
Eduardo Rocha Arruda
AMAlexandre Mendonça Munhoz
Alexandre Mendonça Munhoz
WMWalter Matsumoto
Walter Matsumoto
TUThiago Ueda
Thiago Ueda
EMEduardo Montag
Eduardo Montag
RGRolf Gemperli
Rolf Gemperli
Autologous fat grafting (AFG) has been used in surgical practice as a filling method. However, controversies remain on the specifics of this technique. So far, few relevant experimental large animal studies have objectively assessed factors related to AFG integration. This study uses an experimental medium-sized animal model to compare the feasibility of AFG collected using two different techniques with instruments of distinct thicknesses. Twenty minipigs (Sus scropha domesticus) were subjected to AFG harvesting via en bloc resection using 3 (Group I) and 5 mm diameter (Group II) round punch blades (PB) and liposuction (LS) with 3 (Group III) and 5 mm diameter cannulas (Group IV). Both samples were grafted intramuscularly (biceps femoralis). Hematoxylin and eosin (HE) staining was used to identify intact adipocytes, fat necrosis, fibrosis, inflammation, and oil cysts. Immunohistochemical staining (IHC) (perilipin-A, TNF-α, CD31) were utilized to quantify the feasibility of adipocytes, tissue necrosis, neoangiogenesis, respectively. HE analysis showed that fat necrosis/histiocyte presence were significant lower in the AFG harvested using a PB than in LS. For perilipin-A, a statistical difference was observed between subgroups I and III (p=0.001) and I and IV (p=0.004). Instrument diameter was seen to have no effect on graft integration, as seen in comparisons between groups II and III (p=0.059) and II and IV (p=0.132). In this experimental study, fat collected using a PB demonstrated higher adipocyte viability than fat collected with LS. The diameter of the collection instruments, whether PB or LS, had no effect on graft integration.

1 April 2020 in Plastic and Reconstructive Surgery
Verified
Journal Article
Closed access
AMAlexandre Mendonça Munhoz
Alexandre Mendonça Munhoz

1 November 2021 in RECIMA21 - Revista Científica Multidisciplinar
Verified
Journal Article
Open access
PDF file
WFWesley Oliveira Ferreira
Wesley Oliveira Ferreira
AMAlexandre Munhoz
Alexandre Munhoz
MMMarco Antônio Mantese
Marco Antônio Mantese
O objetivo é abordar as iniciativas agindo de forma proativa para a melhoria do sistema de satélite e venha a ser totalmente operacional. Este estudo visa superar problemas relacionados a um planejamento ineficiente do sistema, onde a antena de satélite é fixada em um suporte o qual acumula água devido a fazer troca de calor, entre os ambiente interno e externo, neste processo de troca de calor entre os ambientes foi puxado a água acumulada que fica no suporte para dentro de si, gerando assim o problema que está em estudo, a infiltração na antena de satélite. Nas analises realizadas, foi utilizado o programa PRTG Monitor Network para monitorar este processo de funcionamento da mesma, observado o mal funcionamento desta antena, foi retirada esta antena da locomotiva para a análise mais aprofundada, e assim constatado que a mesma saia bastante água de dentro dela, pelo respiro, onde ela faz essa troca de calor. Os resultados experimentais mostraram que ao abrir uma circunferência no meio deste suporte foram eficazes, deixando assim a parte do respiro livre entre os ambientes interno e externo, também a manutenção interna de seus componentes eletrônicos, e por último a validação dos níveis de sinais da antena de satélite.