Takayuki Yanagida

Takayuki Yanagida

Auto-generated profile, based on publicly available information

Takayuki Yanagida

Kyushu Institute of Technology

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2013 in Optical Materials
Verified
Journal Article
Closed access
TYTakayuki Yanagida
Takayuki Yanagida
KKKei Kamada
Kei Kamada
YFYutaka Fujimoto
Yutaka Fujimoto
HYHideki Yagi
Hideki Yagi
TYTakagimi Yanagitani
Takagimi Yanagitani

30 January 2007 in Publications of the Astronomical Society of Japan
Verified
Journal Article
Open access
PDF file
TTTadayuki Takahashi
Tadayuki Takahashi
KAKeiichi Abe
Keiichi Abe
MEManabu Endo
Manabu Endo
YEYasuhiko Endo
Yasuhiko Endo
YEYuuichiro Ezoe
Yuuichiro Ezoe
DYDaisuke Yonetoku
Daisuke Yonetoku
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by the combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit background based on a combination of new techniques, including the concept of a well-type active shield counter. With an effective area of $142 \,\mathrm{cm}^{2}$ at 20 keV and $273 \,\mathrm{cm}^{2}$ at 150 keV, the background level at sea level reached $\sim 1 \times 10^{-5} \,\mathrm{cts} \,\mathrm{s}^{-1} \,\mathrm{cm}^{-2} \,\mathrm{keV}^{-1}$ at 30 keV for the PIN diodes, and $\sim 2 \times 10^{-5} \,\mathrm{cts} \,\mathrm{s}^{-1} \,\mathrm{cm}^{-2} \,\mathrm{keV}^{-1}$ at 100 keV, and $\sim 7 \times 10^{-6} \,\mathrm{cts} \,\mathrm{s}^{-1} \,\mathrm{cm}^{-2} \,\mathrm{keV}^{-1}$ at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of $\sim 4 \,\mathrm{cm}$ thick BGO crystals, have a large effective area for sub-MeV to MeV $\gamma$-rays. They work as an excellent $\gamma$-ray burst monitor with limited angular resolution ($\sim 5^{\circ}$). The on-board signal-processing system and the data transmitted to the ground are also described.

8 September 2011 in Crystal Growth & Design
Verified
Journal Article
Closed access
KKKei Kamada
Kei Kamada
TETakanori Endo
Takanori Endo
KTKousuke Tsutumi
Kousuke Tsutumi
TYTakayuki Yanagida
Takayuki Yanagida
YFYutaka Fujimoto
Yutaka Fujimoto
MNMartin Nikl
Martin Nikl

14 May 2014 in Applied Physics Express
Verified
Journal Article
Closed access
TYTakayuki Yanagida
Takayuki Yanagida
YFYutaka Fujimoto
Yutaka Fujimoto
TITakashi Ito
Takashi Ito
KUKoro Uchiyama
Koro Uchiyama
KMKuniyoshi Mori
Kuniyoshi Mori

1 August 2012 in Journal of Crystal Growth
Verified
Journal Article
Closed access
KKKei Kamada
Kei Kamada
TYTakayuki Yanagida
Takayuki Yanagida
TETakanori Endo
Takanori Endo
KTKousuke Tsutumi
Kousuke Tsutumi
YUYoshiyuki Usuki
Yoshiyuki Usuki
AYAkira Yoshikawa
Akira Yoshikawa

30 January 2007 in Publications of the Astronomical Society of Japan
Verified
Journal Article
Open access
PDF file
MKMotohide Kokubun
Motohide Kokubun
KMKazuo Makishima
Kazuo Makishima
TTTadayuki Takahashi
Tadayuki Takahashi
TMToshio Murakami
Toshio Murakami
MTMakoto Tashiro
Makoto Tashiro
TTthe HXD team
the HXD team
The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10–600 keV, energy resolutions of $\sim 4 \,\mathrm{keV}$ (FWHM) at 40 keV and $\sim 11\%$ at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of PIN-Si diodes have been stable within 1% for half a year, and those of scintillators have decreased by 5–20%. The residual non-X-ray background of the HXD is the lowest among past non-imaging hard X-ray instruments in energy ranges of 15–70 and 150–500 keV. We provide accurate calibrations of energy responses, angular responses, timing accuracy of the HXD, and relative normalizations to the X-ray CCD cameras using multiple observations of the Crab Nebula.