Chase M. Hartquist

Chase M. Hartquist

Auto-generated profile, based on publicly available information

Chase M. Hartquist

Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine , St. Louis, MO 63110; , St. Louis, MO 63130

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2025 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
MQMichael Y. Qiu
Michael Y. Qiu
VCVinay Chandrasekaran
Vinay Chandrasekaran
CHChase M. Hartquist
Chase M. Hartquist
HLHalle R. Lowe
Halle R. Lowe
CSCharles B. Suskin
Charles B. Suskin
GGGuy M. Genin
Guy M. Genin
Endovascular procedures require sheaths with contradictory mechanical properties: flexibility for navigation through tortuous vessels, yet rigidity for device delivery. Current approaches rely on multiple device exchanges, increasing procedural time, and complication risks. Here we present a novel endovascular sheath design scheme with dynamically controllable flexural rigidity along its entire length. The device incorporates axially aligned metal string arrays between inner and outer lumens, enabling transition between flexible and rigid states through suction actuation. Three-point bend testing demonstrated that actuation increases flexural rigidity from the range associated with diagnostic catheters to that associated with support sheaths. In simulated contralateral access procedures, the device reduced access time to 1/3 of the time required when using conventional approaches. in vivo porcine studies validated the sheath's ability to navigate tortuous anatomy in its flexible state and successfully support advancement of increasingly rigid therapeutic devices when actuated. Technology enables single-sheath delivery of treatment, potentially reducing procedural complexity, decreasing complication rates, and improving patient outcomes across various endovascular interventions. This design represents a promising approach to combining catheter and sheath design that benefits both peripheral and neurovascular procedures.

5 June 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
CHChase M. Hartquist
Chase M. Hartquist
JLJin Vivian Lee
Jin Vivian Lee
MQMichael Y. Qiu
Michael Y. Qiu
CSCharles Suskin
Charles Suskin
VCVinay Chandrasekaran
Vinay Chandrasekaran
GGGuy M. Genin
Guy M. Genin
Endovascular procedures provide surgeons and other interventionalists with minimally invasive methods to treat vascular diseases by passing guidewires, catheters, sheaths and treatment devices into the vasculature to and navigate toward a treatment site. The efficiency of this navigation affects patient outcomes, but is frequently compromised by catheter “herniation”, in which the catheter-guidewire system bulges out from the intended endovascular pathway so that the interventionalist can no longer advance it. Here, we showed herniation to be a bifurcation phenomenon that can be predicted and controlled using mechanical characterizations of catheter-guidewire systems and patientspecific clinical imaging. We demonstrated our approach in laboratory models and, retrospectively, in patients who underwent procedures involving transradial neurovascular procedures with an endovascular pathway from the wrist, up in the arm, around the aortic arch, and into the neurovasculature. Our analyses identified a mathematical navigation stability criterion that predicted herniation in all of these settings. Results show that herniation can be predicted through bifurcation analysis, and provide a framework for selecting catheter-guidewire systems to avoid herniation in specific patient anatomy.