Sandra Branco

Sandra Branco

Auto-generated profile, based on publicly available information

Sandra Branco


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2025 in RevSALUS - Revista Científica da Rede Académica das Ciências da Saúde da Lusofonia
Verified
Journal Article
Closed access
BSBruno Silva
Bruno Silva
HSHelena Sousa
Helena Sousa
SBSandra Branco
Sandra Branco
PPPaula Portugal
Paula Portugal
ACAna Campolargo
Ana Campolargo
ACAna Cavalheiro
Ana Cavalheiro
Introduction: Peripheral Nerve Injuries significantly impact quality of life and independence, affecting both movement and sensation. Reintegration into daily routines is particularly challenging due to changes in strength and sensitivity of the affected limb, which vary according to the injured nerve. While sensory re-education is recognized for its benefits, there is a gap in the literature regarding specific intervention protocols. Objective: To evaluate the impact of the "Sensory Discrimination Program" on the rehabilitation of sensory deficits in brachial plexus injury. Materials and Methods: A micro-level, multi-method case study focusing on an individual with carpal tunnel syndrome. Assessments were conducted at baseline, midpoint, and final stages, alongside 14 intervention sessions. Various evaluation tools were used, including the Mini Mental State Examination, a three-section questionnaire, Barthel Index, Lawton & Broady Scale, WHOQOL-Bref, and Semmes-Weinstein Monofilaments. Data were analyzed using Microsoft Excel (version 2305). Results: After 14 intervention sessions using the "Sensory Discrimination Program," positive results were observed in sensory rehabilitation for individuals with carpal tunnel syndrome, suggesting a broader impact on peripheral nerve injury rehabilitation. Conclusions: Despite positive outcomes, further studies with larger samples are necessary to reinforce the effectiveness of this program and support occupational therapists in similar cases.

4 September 2025 in JMIR Preprints
Verified
Preprint
Open access
EGEugénio Moita Gonçalves
Eugénio Moita Gonçalves
MSMaria Catarina Silva
Maria Catarina Silva
HRHenrique Ribeiro
Henrique Ribeiro
MAMariana Almeida
Mariana Almeida
BFBernardo Filipe
Bernardo Filipe
CJCristina Jácome
Cristina Jácome
BACKGROUND The Michigan Hand Outcomes Questionnaire (MHQ) is a key instrument for assessing hand and wrist conditions, but a validated version for European Portuguese speakers is unavailable. Furthermore, the potential of an electronic format to improve data collection and clinical workflows has not been formally evaluated. OBJECTIVE This study aimed to translate and culturally adapt the MHQ for European Portuguese and to evaluate the measurement properties and comparability of its paper and electronic formats. METHODS An observational study was conducted in three phases: (1) translation and expert review, (2) content validation through cognitive interviews, and (3) psychometric evaluation in a cohort of 81 adult patients with hand or wrist conditions. Exploratory known-groups analyses were performed according to clinical, sociodemographic, and digital-access variables. Analysis also included internal consistency (Cronbach α and McDonald ω), measurement error (standard error of measurement [SEM]), relative and absolute reliability (intraclass correlation coefficient [ICC], Spearman correlation coefficient [ρ], and Bland-Altman analysis). The electronic format’s usability was assessed with the System Usability Scale (SUS). RESULTS The translation and cognitive interviews confirmed the content validity and conceptual equivalence of the European Portuguese MHQ. The instrument demonstrated excellent internal consistency (Cronbach α=0.85-0.98; McDonald ω=0.88-0.99). Exploratory known-groups analyses showed significant gender-related differences and suggested side-specific clinical discrimination in fracture cases. While group-level relative reliability between formats was strong (ρ=0.68-0.91; ICC=0.76-0.95), individual-level absolute reliability was poor, with wide 95% limits of agreement spanning a 32.83-point interval. Format-related score discrepancies were most pronounced among older participants, those with lower educational attainment, and those with low digital literacy. The electronic MHQ was the preferred format (43 out of 74, 58%), showed acceptable usability (median SUS score 70, IQR 66-88), and had lower SEM in pain and function domains. CONCLUSIONS The European Portuguese MHQ is a relevant and reliable instrument with adequate measurement properties for both clinical practice and research. The electronic version demonstrated superior precision and user preference. However, maintaining the paper format as a viable alternative is essential to ensure equitable access for patients with digital barriers. Due to the overall low absolute reliability between formats, once a patient-preferred format is adopted, it should be used consistently for longitudinal patient monitoring. CLINICALTRIAL

4 September 2025 in JMIR Rehabilitation and Assistive Technologies
Verified
Journal Article
Open access
EGEugénio Moita Gonçalves
Eugénio Moita Gonçalves
MSMaria Catarina Silva
Maria Catarina Silva
HRHenrique Ribeiro
Henrique Ribeiro
MAMariana Almeida
Mariana Almeida
BFBernardo Filipe
Bernardo Filipe
CJCristina Jácome
Cristina Jácome
Background: The Michigan Hand Outcomes Questionnaire (MHQ) is a key instrument for assessing hand and wrist conditions, but a validated version for European Portuguese speakers is unavailable. Furthermore, the potential of an electronic format to improve data collection and clinical workflows has not been formally evaluated. Objective: This study aimed to translate and culturally adapt the MHQ for European Portuguese and to evaluate the measurement properties and comparability of its paper and electronic formats. Methods: An observational study was conducted in three phases: (1) translation and expert review, (2) content validation through cognitive interviews, and (3) psychometric evaluation in a cohort of 81 adult patients with hand or wrist conditions. Exploratory known-groups analyses were performed according to clinical, sociodemographic, and digital-access variables. Analysis also included internal consistency (Cronbach α and McDonald ω), measurement error (standard error of measurement [SEM]), relative and absolute reliability (intraclass correlation coefficient [ICC], Spearman correlation coefficient [ρ], and Bland-Altman analysis). The electronic format’s usability was assessed with the System Usability Scale (SUS). Results: The translation and cognitive interviews confirmed the content validity and conceptual equivalence of the European Portuguese MHQ. The instrument demonstrated excellent internal consistency (Cronbach α=0.85-0.98; McDonald ω=0.88-0.99). Exploratory known-groups analyses showed significant gender-related differences and suggested side-specific clinical discrimination in fracture cases. While group-level relative reliability between formats was strong (ρ=0.68-0.91; ICC=0.76-0.95), individual-level absolute reliability was poor, with wide 95% limits of agreement spanning a 32.83-point interval. Format-related score discrepancies were most pronounced among older participants, those with lower educational attainment, and those with low digital literacy. The electronic MHQ was the preferred format (43 out of 74, 58%), showed acceptable usability (median SUS score 70, IQR 66-88), and had lower SEM in pain and function domains. Conclusions: The European Portuguese MHQ is a relevant and reliable instrument with adequate measurement properties for both clinical practice and research. The electronic version demonstrated superior precision and user preference. However, maintaining the paper format as a viable alternative is essential to ensure equitable access for patients with digital barriers. Due to the overall low absolute reliability between formats, once a patient-preferred format is adopted, it should be used consistently for longitudinal patient monitoring.