21 November 2022 in Mechanics of Advanced Materials and Structures
In magnetic nanoparticle hyperthermia, the magnetic nanoparticles (MNPs) start oscillations when they are exposed to an alternating magnetic field, which may generate ultrasound waves. These resulting oscillations of nanoparticles can lead to the movement of drug carrier liposomes. In this study, a multiphysics coupling model of magnetic nanoparticle behavior in an alternating magnetic field was developed, implementing solid mechanics compliance parameters and piezomagnetic coupling matrices. A detailed sensitivity study was conducted to examine the effects of size and elastic modulus of MNPs, distribution and distance between two MNPs, elasticity and viscosity of the glycerol medium and mesh element sizes on the output displacement signals of MNPs. The results indicated that magnetic nanoparticles undergo some displacements when they are exposed to an alternating magnetic field. These oscillations may generate ultrasound waves, though the amount of displacement for each nanoparticle is negligibly small. It is expected that aggregated nanoparticles result in much higher oscillations.
31 March 2026 in Plasma Physics and Controlled Fusion
An improved geometry for the ITER Fast Ion Loss Detector (FILD) (i.e. Lost Alpha Monitor) collimator has been optimized to maximize the signal-to-noise ratio and resolution for the lost 3.5 MeV fusion-born alpha particles. A new optimization method has been developed to be able to study a broad range of geometries and ensure the best performance through the entire velocity-space of interest. The collimator now presents advanced shaping, fitting the helical trajectories of the ions. Synthetic diagnostic simulations have been conducted with the FILDSIM code to evaluate its performance. These simulations provide the main parameters of the diagnostic, including the gyroradius and pitch angle resolutions, and the collimator factor. Synthetic signals are computed from ASCOT ion distributions to evaluate the optic and data acquisition system of ITER. A scan of the FILD insertion has been performed to evaluate the ion flux at different measuring positions. The synthetic signals in this work show that the new collimator geometry enhances both collimation and resolution, ultimately improving the signal to noise ratio by . These simulations incorporate the latest update on the optical system and multiple sources of noise: scintillator noise generated by gamma and neutron fluxes, camera-induced noise, neutronic noise on the camera sensor, optic transmission and field of view, and distortion due to the optical system.
25 September 2025 in Nuclear Fusion
TTthe EUROfusion Tokamak Exploitation Team
the EUROfusion Tokamak Exploitation Team
+7
In ITER and future fusion power plants, the source of the fusion born alpha particles is almost isotropic in pitch angle, thus having co- and counter-current populations. For trapped ions, the co-current side of the orbit corresponds to its outer leg, while the counter-current side corresponds to the inner leg. Understanding the mechanisms responsible for the fast-ion losses (FILs) is critical for future magnetically confined fusion power plants. To further study the interplay of fast ions with plasma instabilities, a double pinhole collimator has been developed for a Fast-Ion Loss Detector (FILD) in the ASDEX Upgrade tokamak (AUG). This new FILD opens the operational window to simultaneous measurements of the co- and counter-current ion velocity-space. In this paper, the first results for the AUG double collimator FILD detector are shown. The commissioning of this new probe is carried out in H-mode plasmas with an on-axis magnetic field T, and a plasma current MA. Simultaneous co- and counter-current FILs have been measured. Both have shown a similar dependence on Ion Cyclotron Resonance Heating (ICRH) power, where the main difference is the intensity of the losses, with the co-losses being an order of magnitude larger. Toroidal Alfvén eigenmode-coherent ICRH-only losses have been identified for the co-current ions. Additionally, the presence of Edge Localized Modes during the discharge were shown to increment Neutral Beam Injection prompt losses, while partially mitigating ICRH-driven losses on both co- and counter- sides of the velocity-space. Finally, a very trapped and high gyroradius losses, with an unclear origin, have been measured in the co- and counter-current velocity-space. The computed ion trajectories show that these ions remain permanently near the vessel wall, suggesting that they are accelerated within the scrape-off layer.
1 July 2026 in Plasma Physics and Controlled Fusion
Latest advancements in the design of the ITER Lost Alpha Monitor diagnostic, also known as fast-ion loss detector (FILD), are detailed in this article. Advanced Hamiltonian full-orbit simulations are performed to estimate the velocity-space of fast-ion fluxes on the diagnostic probe head. Using the ASCOT code, these fluxes are characterized for different spatial spectra of externally applied 3D fields and probe head insertion depths. The probe head is inserted into the scrape-off layer (positioned at the level of the first wall) using a reciprocating system featuring an internal moving shaft, double bellows for vacuum integrity, and an electric actuator with a total radial stroke of 50 cm. Detailed structural, electromagnetic, and dynamic analyses of this reciprocating system are presented to validate its mechanical robustness against gravitational and induced electromagnetic forces. Thermomechanical modeling of heat loads on the probe head is used to estimate mechanical stresses and scintillator operating temperature. The light pattern emitted by the scintillator is computed using the FILDSIM code, which incorporates scintillator efficiency and orbit simulations. A 14 m long optical relay, featuring free-form mirrors and radiation-hardened lenses, collects and transmits the scintillator light into a shielding cabinet in the port cell. This cabinet houses the instrumentation for data acquisition (DAQ), digitizers for Faraday Cups, photomultiplier tubes, and charge couple device cameras. Monte Carlo simulations estimate radiation-induced noise on the scintillator and the effectiveness of DAQ shielding in the interspace. Together, these advancements ensure an acceptable signal-to-noise ratio of the Lost Alpha Monitor throughout the entire ITER operation.
1 September 2026 in Nuclear Fusion
This paper presents simulations of alpha-particle transport in ITER driven by static 3D magnetic field perturbations in the high-performance baseline scenario, specifically resonant magnetic perturbations arising from edge-localized mode (ELM) control coils, combined with toroidal field ripple and effects from ferromagnetic materials. We employ the Lorentz-Orbit Code for Use in Stellarators and Tokamaks (LOCUST), which tracks fast-ion orbits under the Lorentz force and Monte Carlo collisions with the bulk plasma, taking into account the detailed geometry of ITER plasma-facing components. LOCUST uses GPU cards to enable the high-resolution modelling required to accurately resolve power fluxes across surfaces with complex morphologies, including unprotected cooling pipes beneath the dome divertor, and the generation of reliable synthetic diagnostics for the ITER Fast Ion Loss Detector (FILD) to support its design. The simulations include a range of ELM control coil current profiles with toroidal mode number n = 3. The results indicate that the total alpha-particle energy lost has a negligible impact on plasma performance, remaining below 1% of the alpha energy produced in D–T reactions. Furthermore, the power flux density on the divertor structures and the first wall remains well below design limits and is comparable to thermal and radiative loads. The simulated alpha flux on the FILD scintillator plate is well above the noise threshold and can be significantly higher than conservative estimates.