Li Chen

Li Chen

Auto-generated profile, based on publicly available information

Li Chen

Academy for Engineering and Technology, Fudan University, Shanghai, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YCYuhui Cen
Yuhui Cen
JLJingchun Luo
Jingchun Luo
Hongbo WangHongbo Wang
Hongbo Wang
LCLi Chen
Li Chen
XZXing Zhu
Xing Zhu
Jingjing LuoJingjing Luo
Jingjing Luo
Pulse wave analysis, a non-invasive and cuffless approach, holds promise for blood pressure (BP) measurement in precision medicine. In recent years, pulse wave learning for BP estimation has undergone extensive scrutiny. However, prevailing methods still encounter challenges in grasping comprehensive features from pulse waves and generalizing these insights for precise BP estimation. In this study, we propose a general pulse wave deep learning (PWDL) approach for BP estimation, introducing the OVAR-BPnet model to powerfully capture intricate pulse wave features and showcasing its effectiveness on multiple types of pulse waves. The approach involves constructing population pulse waves and employing a model comprising an omni-scale convolution subnet, a Vision Transformer subnet, and a multilayer perceptron subnet. This design enables the learning of both single-period and multi-period waveform features from multiple subjects. Additionally, the approach employs a data augmentation strategy to enhance the morphological features of pulse waves and devise a label sequence regularization strategy to strengthen the intrinsic relationship of the subnets' output. Notably, this is the first study to validate the performance of the deep learning approach of BP estimation on three types of pulse waves: photoplethysmography, forehead imaging photoplethysmography, and radial artery pulse pressure waveform. Experiments show that the OVAR-BPnet model has achieved advanced levels in both evaluation indicators and international evaluation criteria, demonstrating its excellent competitiveness and generalizability. The PWDL approach has the potential for widespread application in convenient and continuous BP monitoring systems.

7 June 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XZXueze Zhang
Xueze Zhang
MWMinjie Wang
Minjie Wang
Hongbo WangHongbo Wang
Hongbo Wang
FWFuhao Wang
Fuhao Wang
LCLi Chen
Li Chen
Xiaoyang KangXiaoyang Kang
Xiaoyang Kang
Wrist exoskeletons are increasingly being used in the rehabilitation of stroke and hand dysfunction because of its ability to assist patients in high intensity, repetitive, targeted and interactive rehabilitation training. However, the existing wrist exoskeletons cannot effectively replace the work of therapist and improve hand function, mainly because the existing exoskeletons cannot assist patients to perform natural hand movement covering the entire physiological motor space (PMS). Here, we present a bioelectronic controlled hybrid serial-parallel wrist exoskeleton HrWr-ExoSkeleton (HrWE) which is based on the PMS design guidance, the gear set can carry out forearm pronation/supination (P/S) and the 2-DoF parallel configuration fixed on the gear set can carry out wrist flexion/extension (F/E) and radial/ulnar deviation (R/U). This special configuration not only provides enough range of motion (RoM) for rehabilitation training (85F/85E, 55R/55U, and 90P/90S), but also makes it easier to provide the interface for finger exoskeletons and be adapted to upper limb exoskeletons. In addition, to further improve the rehabilitation effect, we propose a HrWE-assisted active rehabilitation training platform based on surface electromyography signals.

19 September 2024 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
QPQiqi Pan
Qiqi Pan
Jingjing LuoJingjing Luo
Jingjing Luo
YFYongfei Feng
Yongfei Feng
LCLi Chen
Li Chen
Hongbo WangHongbo Wang
Hongbo Wang
The coupling effect of the flexible robotic arm with multiple degrees of freedom greatly increases the control complexity. For flexible endoscopic robots that manipulate an endoscope or other necessary channels like gas detection channel, its performance, like adaptability to tortuous paths, simplicity of control, and compactness of size are essential. Currently, there is a tradeoff between multiple-degree of freedom (DOF) and control accuracy of continuum robots. In this article, a self-decoupling continuum robot with multiple stiffness was proposed. Based on the difference in stiffness among segments, the proposed robotic arm can well realize the independent operation of each DOF. Using stiffness analysis and kinematics calculation, the optimal self-decoupling structure model of the robot was determined. With finite element analysis and experimental verification, the control error of the proposed robotic arm is less than 2.5%. The coupling error among segments is less than 6.7%, and the ratio of absolute maximum error to the length of the robotic arm is less than 1.4%.

11 September 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QPQiqi Pan
Qiqi Pan
Jingjing LuoJingjing Luo
Jingjing Luo
LCLi Chen
Li Chen
HXHaodan Xue
Haodan Xue
Hongbo WangHongbo Wang
Hongbo Wang
Force sensing is important in robot-assisted minimally invasive surgery (MIS), but it is still difficult to achieve both miniaturization and multi-dimensional perception at the same time. A modular design scheme of a miniature six-dimensional force sensor that can be integrated into a MIS robot is proposed. The force and moment applied on the sensor are converted into the signal response of the pressure sensitive element, and the position of the pressure sensitive element is located by using flexible printed circuit board (FPCB), with which the wiring of signal circuits is simplified. The blind signal separation Fast Independent Component Analysis (FastICA) algorithm is used to decouple the output signal. The calibration experiment of the proposed sensor was carried out, and the calibration matrix was established. From the comparative experiment with commercial sensors, the accuracy, linearity, hysteresis, coupling error and other performance of the proposed sensor are verified. The maximum coupling error is 2.8% and the maximum stable measuring error is 3.9%. Analysis and experiments proved the rationality and scientificity of the sensor. This work opens up new ideas for the miniaturization, modularization and integration of sensors for surgical robots.