Wei Wang

Wei Wang

Auto-generated profile, based on publicly available information

Wei Wang

From the Mallinckrodt Institute of Radiology, Division of Neuroradiology (F.R., S.J., C.A.R., W.W., A.N., G.G.P.-C., M.M.M.-T., C.D.C., S.K., P.L., T.L.S.B.)

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SHShivayogi Hiremath
Shivayogi Hiremath
ETElizabeth C Tyler-Kabara
Elizabeth C Tyler-Kabara
JWJesse J Wheeler
Jesse J Wheeler
DMDaniel W Moran
Daniel W Moran
RGRobert A Gaunt
Robert A Gaunt
WWWei Wang
Wei Wang
Recent advancement in electrocorticography (ECoG)-based brain-computer interface technology has sparked a new interest in providing somatosensory feedback using ECoG electrodes, i.e., cortical surface electrodes. We conducted a 28-day study of cortical surface stimulation in an individual with arm paralysis due to brachial plexus injury to examine the sensation produced by electrical stimulation of the somatosensory cortex. A high-density ECoG grid was implanted over the somatosensory and motor cortices. Stimulation through cortical surface electrodes over the somatosensory cortex successfully elicited arm and hand sensations in our participant with chronic paralysis. There were three key findings. First, the intensity of perceived sensation increased monotonically with both pulse amplitude and pulse frequency. Second, changing pulse width changed the type of sensation based on qualitative description provided by the human participant. Third, the participant could distinguish between stimulation applied to two neighboring cortical surface electrodes, 4.5 mm center-to-center distance, for three out of seven electrode pairs tested. Taken together, we found that it was possible to modulate sensation intensity, sensation type, and evoke sensations across a range of locations from the fingers to the upper arm using different stimulation electrodes even in an individual with chronic impairment of somatosensory function. These three features are essential to provide effective somatosensory feedback for neuroprosthetic applications.

1 July 2017 in Cortex
Verified
Journal Article
Closed access
YYYing Yang
Ying Yang
MDMichael Walsh Dickey
Michael Walsh Dickey
JFJulie Fiez
Julie Fiez
BMBrian Murphy
Brian Murphy
TMTom Mitchell
Tom Mitchell
WWWei Wang
Wei Wang

16 February 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
FRF. Rahmani
F. Rahmani
SJS. Jindal
S. Jindal
CRC.A. Raji
C.A. Raji
WWW. Wang
W. Wang
ANA. Nazeri
A. Nazeri
TBTammie Benzinger
Tammie Benzinger
BACKGROUND AND PURPOSE: Automated volumetric analysis of structural MR imaging allows quantitative assessment of brain atrophy in neurodegenerative disorders. We compared the brain segmentation performance of the AI-Rad Companion brain MR imaging software against an in-house FreeSurfer 7.1.1/Individual Longitudinal Participant pipeline. MATERIALS AND METHODS: T1-weighted images of 45 participants with de novo memory symptoms were selected from the OASIS-4 database and analyzed through the AI-Rad Companion brain MR imaging tool and the FreeSurfer 7.1.1/Individual Longitudinal Participant pipeline. Correlation, agreement, and consistency between the 2 tools were compared among the absolute, normalized, and standardized volumes. Final reports generated by each tool were used to compare the rates of detection of abnormality and the compatibility of radiologic impressions made using each tool, compared with the clinical diagnoses. RESULTS: We observed strong correlation, moderate consistency, and poor agreement between absolute volumes of the main cortical lobes and subcortical structures measured by the AI-Rad Companion brain MR imaging tool compared with FreeSurfer. The strength of the correlations increased after normalizing the measurements to the total intracranial volume. Standardized measurements differed significantly between the 2 tools, likely owing to differences in the normative data sets used to calibrate each tool. When considering the FreeSurfer 7.1.1/Individual Longitudinal Participant pipeline as a reference standard, the AI-Rad Companion brain MR imaging tool had a specificity of 90.6%–100% and a sensitivity of 64.3%–100% in detecting volumetric abnormalities. There was no difference between the rate of compatibility of radiologic and clinical impressions when using the 2 tools. CONCLUSIONS: The AI-Rad Companion brain MR imaging tool reliably detects atrophy in cortical and subcortical regions implicated in the differential diagnosis of dementia.

1 July 2013
Verified
Conference Paper
Open access
SPSagi Perel
Sagi Perel
PSPatrick T. Sadtler
Patrick T. Sadtler
JGJason M. Godlove
Jason M. Godlove
SRStephen I. Ryu
Stephen I. Ryu
WWWei Wang
Wei Wang
SCSteven M. Chase
Steven M. Chase
Primary motor-cortex multi-unit activity (MUA) and local-field potentials (LFPs) have both been suggested as potential control signals for brain-computer interfaces (BCIs) aimed at movement restoration. Some studies report that LFP-based decoding is comparable to spiking-based decoding, while others offer contradicting evidence. Differences in experimental paradigms, tuning models and decoding techniques make it hard to directly compare these results. Here, we use regression and mutual information analyses to study how MUA and LFP encode various kinematic parameters during reaching movements. We find that in addition to previously reported directional tuning, MUA also contains prominent speed tuning. LFP activity in low-frequency bands (15-40Hz, LFP L ) is primarily speed tuned, and contains more speed information than both high-frequency LFP (100-300Hz, LFP H ) and MUA. LFP H contains more directional information compared to LFP L , but less information when compared with MUA. Our results suggest that a velocity and speed encoding model is most appropriate for both MUA and LFP H , whereas a speed only encoding model is adequate for LFP L .

26 November 2022 in arXiv
Verified
Preprint
Open access
PDF file
JLJiyang Li
Jiyang Li
WWWei Wang
Wei Wang
KBKratika Bhagtani
Kratika Bhagtani
YJYincheng Jin
Yincheng Jin
ZJZhanpeng Jin
Zhanpeng Jin
With the increasing demands of emotion comprehension and regulation in our daily life, a customized music-based emotion regulation system is introduced by employing current EEG information and song features, which predicts users' emotion variation in the valence-arousal model before recommending music. The work shows that: (1) a novel music-based emotion regulation system with a commercial EEG device is designed without employing deterministic emotion recognition models for daily usage; (2) the system considers users' variant emotions towards the same song, and by which calculate user's emotion instability and it is in accordance with Big Five Personality Test; (3) the system supports different emotion regulation styles with users' designation of desired emotion variation, and achieves an accuracy of over $0.85$ with 2-seconds EEG data; (4) people feel easier to report their emotion variation comparing with absolute emotional states, and would accept a more delicate music recommendation system for emotion regulation according to the questionnaire.