Visvaraja Subrayan

Visvaraja Subrayan

Auto-generated profile, based on publicly available information

Visvaraja Subrayan

Department of Ophthalmology, University of Malaya, Kuala Lumpur, Malaysia

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
WLWei Wei Lee
Wei Wei Lee
ITIqbal Tajunisah
Iqbal Tajunisah
Sharmilla KanagasundramSharmilla Kanagasundram
Sharmilla Kanagasundram
MPMohammadreza Peyman
Mohammadreza Peyman
VSVisvaraja Subrayan
Visvaraja Subrayan
Purpose. We determined structural retinal nerve fiber layer (RNFL) changes in schizophrenia patients and established if the structural changes were related to the duration of the illness using spectral-domain optical coherence tomography (SD-OCT). Methods. We recruited a total of 30 schizophrenic patients and 30 age-matched controls in the study. The schizophrenic patients were subdivided further to acute (n = 5), chronic (n = 13), and long-term chronic (n = 12) subgroups depending on their duration of illness. Using SD-OCT, the peripapillary RNFL thickness, macula thickness, and macula volume measurements of schizophrenic patients and the control subjects were measured and compared at each location. Results. Schizophrenic patients showed a statistically significant reduction in overall peripapillary RNFL thickness (cases, 94.70 ± 9.88 μm; controls, 103.53 ± 6.53 μm; P < 0.001), macula thickness (cases, 269.26 ± 12.59 μm; controls, 284.83 ± 9.76 μm; P < 0.001), and macula volume (cases, 9.61 ± 0.45 mm3; controls, 10.17 ± 0.35 μm; P < 0.001). Chronic and long-term chronic schizophrenic patients were found to have significant peripapillary RNFL thinning, macula thinning, and reduction of macula volume when compared to controls (P < 0.001). There also was a statistically significant reverse correlation (P < 0.05) of peripapillary RNFL thickness (r = −0.36), macula thickness (r = −0.38), and macula volume reduction (r = −0.36) with the duration of schizophrenic illness. Conclusions. These results indicate that RNFL and macula thickness, as well as macula volume measurements are reduced in schizophrenic patients. The degree of thinning and reduction was more significant in the chronic phase of the disease and correlated with the duration of illness. These findings demonstrate that SD-OCT can be a useful tool for the diagnosis and monitoring the progression of this disease.

1 June 2013 in Cornea
Verified
Journal Article
Closed access
LTLai-Yong Tai
Lai-Yong Tai
KKKeat-Ween Khaw
Keat-Ween Khaw
CNChoung-Min Ng
Choung-Min Ng
VSVisvaraja Subrayan
Visvaraja Subrayan
The aim of this study was to compare 4 methods of central corneal thickness (CCT) measurements in terms of their agreement, repeatability, and measurement time. CCT was measured in 184 eyes of 92 healthy subjects by the same examiner. The methods used were as follows: noncontact specular microscopy (SM; Topcon SP-3000P; Topcon Corporation, Tokyo, Japan), Pentacam rotating Scheimpflug photography system (Oculus Inc, Wetzlar, Germany), optical low-coherence reflectometry (OLCR; LenStar LS900; Haag-Streit AG, Koeniz, Switzerland), and ultrasound pachymetry (UP; PachPen; Accutome Inc, Malvern, PA). The duration for each examination was measured by an independent observer. The mean age (±SD) of the subjects was 54.3 (± 15.3) years. The mean CCTs (± SD) for SM, Pentacam, OLCR, and UP were 507.8 (± 30.2), 538.4 (± 31.7), 531.8 (± 31.4), and 528.3 (± 32.9) μm, respectively. The Bland-Altman plots showed closest agreement for OLCR-UP, followed by OLCR-Pentacam and Pentacam-UP. SM had the poorest agreement with the other methods. CCTs measured by SM were on average 20 to 30 μm thinner than those of the other methods. The coefficient of repeatability for SM, Pentacam, OLCR, and UP were 3.14%, 4.23%, 1.51%, and 3.46%, respectively. The mean measurement times (± SD) were 13.5 (± 5.7), 45.7 (± 12.3), 18.5 (± 7.1), and 5.6 (± 1.0) seconds, respectively. CCT measurements between OLCR-UP and OLCR-Pentacam are comparable and can be used interchangeably in clinical practice. However, SM underestimates CCT compared with the other methods, whereas Pentacam was found to be the least repeatable and took the longest time.

1 August 2010 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
HSHoy Choong Shin
Hoy Choong Shin
VSVisvaraja Subrayan
Visvaraja Subrayan
ITIqbal Tajunisah
Iqbal Tajunisah
To evaluate changes in anterior chamber depth (ACD) and intraocular pressure (IOP) after phacoemulsification in eyes with occludable angles and compare the results with those in eyes with normal open angles. Eye Clinic, Ipoh General Hospital, Ipoh, Perak, Malaysia. Patients with nonglaucomatous eyes with open angles or with occludable angles were recruited. Ocular biometric measurements (ACD, axial length [AL], lens thickness and position) and IOP (tonometry) were performed preoperatively and 1 day and 1, 4, 9, and 12 weeks postoperatively. The open-angle group and occludable-angle group each comprised 35 patients. The occludable-angle group had a shallower ACD, shorter AL, thicker and relatively anterior lens position, and higher IOP preoperatively; postoperatively, there was a significant increase in ACD and a significant reduction in IOP (P<.01). Anterior chamber deepening was inversely related to preoperative ACD in the occludable-angle group (P<.01). The mean preoperative IOP was higher in the occludable-angle group (15.77 mm Hg +/- 2.20 [SD]) than in the open-angle group (14.52 +/- 2.65 mm Hg) (P<.05). The IOP dropped progressively and significantly over 12 weeks postoperatively; the mean decrease was 2.31 +/- 0.99 mm Hg in the occludable-angle group and 0.77 +/- 1.17 mm Hg in the open-angle group. The IOP decrease in the occludable-angle group was inversely related to the preoperative IOP (P<.01). Phacoemulsification led to anterior chamber deepening and lower IOP in eyes with occludable angles, which suggests it is an option for preventing acute angle-closure attacks in eyes with occludable angles and cataract. No author has a financial or proprietary interest in any material or method mentioned.

11 March 2011 in Eye
Verified
Journal Article
Open access
PDF file
SJS Jasvinder
S Jasvinder
TKT F Khang
T F Khang
KSK K S Sarinder
K K S Sarinder
VLV P Loo
V P Loo
VSV Subrayan
V Subrayan
To assess the agreement of the optical low-coherence reflectometry (OLCR) device LENSTAR LS900 with partial coherence interferometry (PCI) device IOLMaster and applanation and immersion ultrasound biometry. We conducted the study at the Ophthalmology Clinic, University of Malaya Medical Center, Malaysia. Phakic eyes of 76 consecutive cataract patients were measured using four different methods: IOLMaster, LENSTAR and A-scan applanation and immersion ultrasound biometry. We assessed the method agreement in the LENSTAR-IOLMaster, LENSTAR-applanation, and LENSTAR-immersion comparisons for axial length (AL) and intraocular lens (IOL) power using Bland–Altman plots. For average K, we compared LENSTAR with IOLMaster and the TOPCON KR-8100 autorefractor-keratometer. SRK/T formula was used to compute IOL power, with emmetropia as the target refractive outcome. For all the variables studied, LENSTAR agreement with IOLMaster is strongest, followed by those with immersion and applanation. For the LENSTAR-IOLMaster comparison, the estimated proportion of differences falling within 0.33 mm from zero AL and within 1D from zero IOL power is 100%. The estimated proportion of differences falling within 0.5 D from zero average K is almost 100% in the LENSTAR-IOLMaster comparison but 88% in the LENSTAR-TOPCON comparison. The proportion of differences falling within 0.10 mm (AL) and within 1D (IOL power) in the LENSTAR-IOLMaster comparison has practically significant discrepancy with that of LENSTAR-applanation and LENSTAR-immersion comparisons. In phakic eyes of cataract patients, measurements of AL, average K, and IOL power calculated using the SRK/T formula from LENSTAR are biometrically equivalent to those from IOLMaster, but not with those from applanation and immersion ultrasound biometry.

1 March 2003 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
IKIngrid Kielhorn
Ingrid Kielhorn
MRMadhavan S. Rajan
Madhavan S. Rajan
PTPeter M. Tesha
Peter M. Tesha
VSVisva Raja Subryan
Visva Raja Subryan
JBJohn A. Bell
John A. Bell
To compare axial lengths and intraocular lens (IOL) power calculations obtained with the Zeiss IOLMaster by 2 observers with different training grades and to assess the agreement between optical and acoustic biometry. Department of Ophthalmology, Pembury Hospital, The Laser Eye Clinic, Kent, United Kingdom. In this prospective study, optical biometry was performed twice in 79 patients: first by a qualified ophthalmic nurse and second by 1 of several health care assistants without formal nursing training. In the same group of patients, the qualified nurse also obtained ultrasonic measurements to compare the 2 clinical methods. There was a high correlation coefficient for axial length and IOL power measurements (0.99 each) between the experienced examiner and the inexperienced examiners. The coefficient of repeatability (2 SD) was 0.58 diopter (D) for IOL power (mean 0.04 D) and 0.07 mm for the axial length (mean 0.00 mm). The correlation coefficient of IOLMaster measurements with A-scan measurements done by the same experienced ophthalmic nurse was 0.97 for IOL power and 0.98 for axial length. The limits of agreement (mean +/- 2 SD) were between +0.50 and -2.40 D for IOL power calculations and between +0.7 mm and -0.2 mm for axial length measurements. Optical biometry showed excellent repeatability using different examiners regardless of their medical training. The agreement with ultrasonic measurements and the precision of the method need further evaluation.

1 December 2005 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
VSVisvaraja Subrayan
Visvaraja Subrayan
BMBrid Morris
Brid Morris
AAAna Maria Armbrecht
Ana Maria Armbrecht
AWAlan F. Wright
Alan F. Wright
BDBaljean Dhillon
Baljean Dhillon