Adele Chin Wei Ng

Adele Chin Wei Ng

Auto-generated profile, based on publicly available information

Adele Chin Wei Ng

Department of Otorhinolaryngology–Head & Neck Surgery, SingHealth Duke-NUS Sleep Centre, Singapore General Hospital (SGH), Singapore, Singapore

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2025 in Sleep and Breathing
Verified
Journal Article
Closed access
YHYunrui Hao
Yunrui Hao
NTNicole Kye Wen Tan
Nicole Kye Wen Tan
EGEsther Yanxin Gao
Esther Yanxin Gao
JAJoy Xin Yi Au
Joy Xin Yi Au
NTNovelle En Xian Toh
Novelle En Xian Toh
STSong Tar Toh
Song Tar Toh

8 December 2025 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Open access
PDF file
EGEsther Yanxin Gao
Esther Yanxin Gao
YHYunrui Hao
Yunrui Hao
NTNicole Kye Wen Tan
Nicole Kye Wen Tan
ANAdele Chin Wei Ng
Adele Chin Wei Ng
ZLZhou Hao Leong
Zhou Hao Leong
STSong Tar Toh
Song Tar Toh
Study objectives Obstructive sleep apnea (OSA) is a prevalent but underdiagnosed condition linked to serious health risks. Due to the limited accessibility of polysomnography (PSG), AI (Artificial Intelligence)-based speech analysis has gained attention as a non-invasive screening tool. This Bayesian meta-analysis evaluates the diagnostic accuracy of AI models trained on awake speech and examines factors affecting performance. Methods We systematically searched Medline/PubMed, Embase, Scopus, Web of Science, and IEEE Xplore databases. Eligible studies included adults with OSA diagnosis via in-lab polysomnography or home sleep apnea tests and evaluated AI models using speech recordings. Models evaluated using random-split test sets or k-fold cross-validation were included in a Bayesian bivariate meta-analysis and meta-regression. Publication bias was examined using a selection model approach, while risk of bias and evidence quality were assessed with QUADAS-2 and GRADE. Results From 6,254 screened articles, 8 studies comprising 24 AI models, trained and tested on 1,060 and 825 participants were included. All studies used professional microphone recordings in the controlled hospital settings. AI models analysing awake speech recordings demonstrated pooled sensitivity and specificity of 82.9% (95% CrI: 80.0–86.4%) and 83.3% (95% CrI: 80.7–86.1%), respectively. The diagnostic odds ratio was 24.3 (95% CrI: 18.2–35.0). Higher mean age improved sensitivity. No significant effects were seen for OSA severity, model type, OSA prevalence, or male percentage. Publication bias was not evident. Conclusion AI models trained on awake speech recordings demonstrate good diagnostic accuracy for OSA and hold potential as a practical, scalable screening tool in both clinical and community-based settings.

16 November 2025 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
SRShahana Rani
Shahana Rani
EGEsther Yanxin Gao
Esther Yanxin Gao
JOJoel Zuo Er Ong
Joel Zuo Er Ong
NTNicole Kye Wen Tan
Nicole Kye Wen Tan
ANAdele Chin Wei Ng
Adele Chin Wei Ng
STSong Tar Toh
Song Tar Toh

25 September 2026 in Journal of Medical Internet Research
Verified
Journal Article
Open access
BYBrian Sheng Yep Yeo
Brian Sheng Yep Yeo
EGEsther Yanxin Gao
Esther Yanxin Gao
ETErn Xin Joan Tan
Ern Xin Joan Tan
JKJun Yuan Koo
Jun Yuan Koo
YLYi Siang Lee
Yi Siang Lee
STSong Tar Toh
Song Tar Toh
Background: The traditional method for diagnosing obstructive sleep apnea (OSA) through polysomnography may be expensive and inaccessible. Recent developments in AI propose the use of photoplethysmography (PPG) to aid OSA diagnosis. Objective: This study seeks to evaluate the diagnostic accuracy of an AI-based approach in diagnosing OSA using PPG. Methods: PubMed, Embase, Scopus, Web of Science, and IEEE Xplore were searched from inception to November 3, 2025. The inclusion criteria comprised observational studies that evaluated the accuracy of AI-based methods of OSA diagnosis using PPG compared with conventional sleep testing used in adults. We excluded case reports, case series, reviews, meta-analyses, letters, conference abstracts, pediatric studies, animal studies, foreign language studies, studies with incomplete data, and studies focusing on individual apneic events without patient-level classification. The outcome of interest was the diagnostic accuracy of PPG-based AI models for OSA, as assessed in primary studies using random split tests, cross-validation, or external validation. Independent reviewers extracted data and assessed risk of bias using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool. A Bayesian bivariate meta-analysis was used to pool estimates. Further subgroup, sensitivity, and meta-regression analyses were conducted. Overall quality of evidence was assessed using the GRADE (Grading of Recommendations, Assessment, Development and Evaluations) framework. Results: From 12,579 records, we included 13 studies, comprising 9983 participants. All studies were rated as either low or unclear for risk of bias. The overall evidence quality was moderate. AI trained on PPG achieved a pooled sensitivity of 79.6% (95% credible interval [CrI] 55.5%‐93.8%) and specificity of 76.5% (95% CrI 48.2%‐94.0%), compared to conventional diagnosis. The overall specificity increased (apnea-hypopnea index [AHI] ≥5: 63.6%; AHI ≥15: 81.8%; AHI ≥30: 85.1%), but overall sensitivity decreased (AHI ≥5: 87.2%; AHI ≥15: 79.7%; AHI ≥30: 76.7%) with greater categorical AHI severity cutoffs. Additionally, deep learning models achieved a higher specificity (82.9%) than traditional machine learning (63.6%). OSA prevalence and device type were not clearly associated with sensitivity or specificity. Conclusions: AI models trained on PPG have reasonable accuracy and may potentially serve as a low-cost screening tool. However, limitations such as small sample sizes, potential sources of bias, underrepresentation of certain geographic regions, and the influence of potential confounding factors highlight the necessity for further research. Future work should focus on deep learning to improve the feasibility and accessibility of this approach in primary care.

1 December 2020 in Laryngoscope Investigative Otolaryngology
Verified
Journal Article
Open access
PDF file
ANAdele Chin Wei Ng
Adele Chin Wei Ng
PSParag Ratnakar Salkade
Parag Ratnakar Salkade
MRMahalakshmi Rangabashyam
Mahalakshmi Rangabashyam
SLShaun Ray Han Loh
Shaun Ray Han Loh
STSong Tar Toh
Song Tar Toh
Objective(s): Obstructive sleep apnoea is characterized by repetitive obstruction of the upper airway during sleep. These repeated oxygen desaturations increase cardiovascular and cerebrovascular morbidity and mortality significantly. Upper airway surgery is an option for patients who fail continuous positive airway pressure therapy. Airway collapse is usually multilevel and hypopharyngeal collapse is a challenging area to address. It is hypothesized that hyoid expansion with hyomandibular suspension can potentially increase upper airway dimensions at the hypopharynx. This study aims to document the effect of hyoid expansion using titanium plate and screws with hyomandibular suspension on hypopharyngeal airway dimensions. It is an anatomical feasibility study performed using 10 human cadaver heads. Methods: The hyoid bone is trifractured. The expanded hyoid is then suspended to the mandible. Computed tomography (CT) scans were performed on the cadavers to measure the airway dimensions before and after the procedure. Results: This procedure resulted in statistically significant increase in airway dimensions at the level of the hypopharynx in all 10 human cadaver heads. Increase in cross-sectional area correlated significantly with increase in 3-dimentional (3D) volume. The mean area of the airway at the level of the hyoid increased from 999.3 +/- 193.0 mm(2)to 1241.4 +/- 103.2 mm(2). Statistically significant increase in upper airway volume based on 3D reconstruction was also noted. Upper airway volume increased from 6.94 +/- 6.46 mL to 13.58 +/- 8.29 mL. Conclusion Airway dimensions increased with hyoid expansion and hyomandibular suspension in our cadaveric study measured using CT scans. Further studies are needed to see if this technique can be translated to clinical use in live patients.

8 July 2026 in Journal of Medical Internet Research
Verified
Journal Article
Open access
KYKvan Jie Ming Yam
Kvan Jie Ming Yam
CLClaire Yi Jia Lim
Claire Yi Jia Lim
EGEsther Yanxin Gao
Esther Yanxin Gao
JKJin Hean Koh
Jin Hean Koh
NTNicole Kye Wen Tan
Nicole Kye Wen Tan
STSong Tar Toh
Song Tar Toh
Background: Obstructive sleep apnea (OSA) affects 38% of the population, yet over 90% of cases remain undiagnosed. The gold standard for diagnosis, polysomnography, requires specialized equipment and trained personnel, making it inaccessible in primary care and acute settings. With artificial intelligence (AI) advancements, oximetry-based AI models have emerged as potential alternatives for OSA diagnosis. Objective: This meta-analysis aims to evaluate the diagnostic accuracy of AI models trained on pulse oximetry readings in diagnosing OSA. Methods: A systematic search was conducted across Medline/PubMed, Embase, Scopus, Web of Science, and IEEE Xplore databases from inception to January 3, 2026. Studies that evaluated the diagnostic accuracy of AI models trained on oxygen saturation recordings, compared to the apnea-hypopnea index (AHI) as the reference standard, were included and screened by 2 blinded independent reviewers. Models were evaluated using Bayesian bivariate meta-analysis and meta-regression. Publication bias was examined using a selection model approach, while risk of bias and evidence quality were assessed with Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) and Grading of Recommendations Assessment, Development, and Evaluation (GRADE). Results: From 13,986 screened articles, 25 studies met the inclusion criteria, encompassing 23,171 participants with a mean age of 40 (SD 10.6) to 63 (SD 13.3) years and a BMI of 25 to 37 kg/m 2 . AI-oximetry models demonstrated a pooled sensitivity of 91.1% (95% credible interval [CrI] 89.7%‐92.4%) and specificity of 88.4% (95% CrI 85.3%‐90.8%). Neural network classifiers achieved the highest sensitivity (92.7%) and specificity (91.3%). Deep learning feature extraction models were significantly higher in sensitivity (by 3.7%; 95% CrI 0.9%-6.9%) than domain expert-based approaches. Sensitivity decreased slightly with higher AHI cutoffs, while specificity increased by 16.6% from an AHI cutoff of ≥5 to ≥30. Sensitivity analyses showed that even with up to 40% probability of an unpublished study, changes in accuracy were modest (area under the curve: 0.902 to 0.877). QUADAS-2 and GRADE assessments found low-moderate risk of bias with high overall quality of evidence. Conclusions: AI-oximetry models showed high diagnostic accuracy for OSA across models and AHI cutoffs, performing better than or comparably to traditional overnight oximetry and home sleep apnea tests. This review provides the first pooled quantitative synthesis of AI models trained solely on oximetry data, with additional evaluations of publication bias and methodological limitations. Prior reviews were largely narrative or used alternative AI inputs other than oximetry. This study advances the field by offering a clearer and more reliable evidence base on pooled AI oximetry performance. These findings support the potential of oximetry-based AI as a convenient and scalable tool for OSA screening and diagnosis, with potential real-world applications in both primary care and inpatient settings for early identification of high-risk patients. Prospective external validation in diverse populations and low-prevalence settings is still needed before widespread real-world use.