Scanning electrochemical cell microscopy (SECCM) is a new pipette-based imaging technique purposely designed to allow simultaneous electrochemical, conductance, and topographical visualization of surfaces and interfaces. SECCM uses a tiny meniscus or droplet, at the end of a double-barreled (theta) pipette, for high-resolution functional imaging and nanoscale electrochemical measurements. Here we introduce this technique and provide an overview of its principles, instrumentation, and theory. We discuss the power of SECCM in resolving complex structure-activity problems and provide considerable new information on electrode processes by referring to key example systems, including graphene, graphite, carbon nanotubes, nanoparticles, and conducting diamond. The many longstanding questions that SECCM has been able to answer during its short existence demonstrate its potential to become a major technique in electrochemistry and interfacial science.
There is a prevailing and widely adopted view that carbon nanotubes, which are finding considerable application in energy, healthcare, and electronics applications, are highly (electro)catalytically inert unless modified, doped, or defected. By visualizing the electrochemical reduction of oxygen (hydrogen peroxide generation) at high resolution along pristine (defect-free) regions of individual single-walled carbon nanotubes, we show that there is, in fact, significant activity comparable to that of standard gold electrocatalysts. Moreover, the activity is greatly enhanced at strained (kinked) sites and regions modified by oxidation. Single-walled carbon nanotubes are thus effective electrocatalysts in their own right and not just supports for other materials.