13 December 2017 in The American Journal of Sports Medicine
Background: Previous research has revealed decreased bone mineral density (BMD) among children and adolescents who receive methylphenidate (MP) treatment for attention deficit hyperactivity disorder (ADHD). These findings have major clinical implications given that the prevalence of medication-treated ADHD is on the rise worldwide. We decided to investigate the clinical effect of MP exposure on the incidence of stress fractures, for which a low BMD is a risk factor. Hypothesis: Exposure to MP is a risk factor for stress fractures. Study Design: Case-control study; Level of evidence, 3. Methods: This is a case-control study of combat soldiers who served in the military for 3 years between 2005 and 2015. The case group included 2400 soldiers with at least 1 stress fracture diagnosed by a bone scan. The control group comprised 6187 combat soldiers without a diagnosis of a stress fracture. The use of MP was determined by an automated text search of medical records and manual sorting of the results. Other study variables included age; sex; weight; height; body mass index (BMI); place of birth; and characterization of fractures by location, side, and grade. Odds ratios of stress fractures, the attributable proportion among the exposed, and the population attributable fraction were calculated using standard contingency tables. Logistic regression was fitted after adjusting for covariates. Results: The previous use of MP was associated with a higher risk of stress fractures (odds ratio, 1.15 [95% CI, 1.07-1.24]). The attributable proportion was 13.2%, and the population attributable fraction was 0.3%. Logistic regression demonstrated an increased risk of stress fractures associated with past MP use, preserved after adjusting for BMI, sex, and place of birth ( P = .005). Female sex, BMI ≤20 kg/m 2 , and 20 < BMI ≤25 kg/m 2 were independent positive predictors of a stress fracture, while African origin was a negative predictor. Most participants who used MP had only 1 fracture (77.8%), while the majority of participants who did not use MP in the past had ≥2 coincident fractures (53.5%) ( P = .003). Conclusion: This study supports the hypothesis that an MP-associated reduction in BMD has a clinical effect in the form of an increased incidence of stress fractures. The high percentage of fractures attributed to MP use may serve as a basis for risk stratification, that is, the referral of patients with a history of MP use to BMD measurements.
26 March 2016 in Knee Surgery, Sports Traumatology, Arthroscopy
16 November 2019 in Archives of orthopaedic and trauma surgery
1 July 2016 in Orthopaedic Nursing
When patients are asked a general question, whether they suffer from any complications, they tend to underreport the presence of such complications. Complete and comprehensive interviews of the patient may give us a better understanding of the true incidence of complications.
1 August 2018 in Journal of Hip Preservation Surgery
The most common types of cystic lesions around the hip joint are synovial or ganglion cysts. In rare cases, the cysts can compress adjacent structures and cause symptoms to arise. Obturator neuropathy secondary to a hip ganglion cyst is a rare phenomenon, with scarce reports on suggested treatment options. Hip arthroscopy is a potential minimally invasive treatment that has yet to be described in such cases. We present a 52-year-old male suffering from obturator neuropathy caused by an intra-pelvic ganglion cyst arising from the hip joint. Hip arthroscopy was performed for decompression of the cyst and dilation of the stalk opening. Six-month post-operative follow-up showed resolution of symptoms and complete elimination of the cyst on magnetic resonance imaging.
22 March 2023 in Journal of Hip Preservation Surgery
MGMatheus Almeida Guberovich
Matheus Almeida Guberovich
+1
Arthroscopy and endoscopic hip surgery have attracted increasing attention in the orthopedic field. In the case of arthroscopy, portals and their relationships with neurovascular bundle structures at risk are well established. However, studies on endoscopic portals used for the repair of hamstring tendon injuries are insufficient. Hamstring injuries are the most common muscle injury in sports medicine, and up to 12% can present as a tendon rupture. Endoscopic surgery is advantageous because it has a lower rate of bleeding and avoids excessive handling of the gluteal muscles. The objective of this study is to perform an anatomical evaluation of endoscopic portals for hamstring repair and measure their distance to neurovascular structures—mainly sciatic nerve and posterior femoral cutaneous nerve (PFCN). Fifteen hips from frozen and formalized cadavers were evaluated. Specimens that showed any modification in their anatomy were excluded. Portals were simulated using Steinmann pins, and anatomical dissection was performed. Distances from neurovascular structures were measured using a digital caliper. Four male cadaver hips (26%) and eleven female cadaver hips (74%) were included. Two dissected hips presented PFCN injury through the posterolateral portal— mean 20.28 mm (±8.14), and one through the distal accessory portal— 21.87 mm (±12.03). The injury rate for PFCN was 3/15 or 20%. None of the portals presented sciatic nerve injury. Conclusion: There is an imminent risk of nerve injury to the PFCN by performing the lateral portals for hamstring repair. To avoid this, we recommend starting the procedure through the most medial (posteromedial) portal, and the other portals must be performed under direct visualization.