Steven Sourbron

Steven Sourbron

Auto-generated profile, based on publicly available information

Steven Sourbron

Division of Medical Physics, University of Leeds, Leeds, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2013 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
SSSteven P. Sourbron
Steven P. Sourbron
DBDavid L. Buckley
David L. Buckley

7 March 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SSSteven P. Sourbron
Steven P. Sourbron
DBDavid L. Buckley
David L. Buckley
The Tofts model (TM) and extended Tofts model (ETM) have become a standard for the analysis of dynamic contrast‐enhanced MRI. In this study, a mathematical analysis is used to identify exactly in which tissue types the Tofts models may be applied. The results show that the TM is accurate if and only if the tissue is weakly vascularised (small blood volume). The ETM is additionally accurate in highly perfused tissues (high blood flow). In tissues that are highly vascularised, or where tracer exchange is very fast or very slow, TM and ETM accurately fit the data but lead to a misinterpretation of the parameters. In tissue types with intermediate vascularity, perfusion and tracer exchange, neither model offers a good fit to the tissue concentrations. A good fit can be obtained with a measured input function by reducing the temporal resolution, but this does not improve the accuracy of the parameters. In conclusion, the Tofts models only produce reliable parameter values if the tissue is weakly vascularized (TM or ETM) or highly perfused (ETM). Without prior knowledge that at least one of these constraints is fulfilled, the physiological interpretation of the values produced by the Tofts models is unclear. Magn Reson Med, 2011.

1 December 2010 in European Journal of Radiology
Verified
Journal Article
Closed access
SSSteven Sourbron
Steven Sourbron

1 June 2012 in Radiology
Verified
Journal Article
Closed access
SSSteven Sourbron
Steven Sourbron
WSWieland H. Sommer
Wieland H. Sommer
MRMaximilian F. Reiser
Maximilian F. Reiser
CZChristoph J. Zech
Christoph J. Zech
To evaluate the feasibility of quantifying hepatic perfusion and function by using dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging with the hepatobiliary contrast agent gadoxetic acid and a dual-inlet two-compartment uptake model. The study was approved by the local institutional review board, and written informed consent was obtained from all patients. Data were acquired between October 2008 and November 2009 in 24 patients with hepatic metastases from neuroendocrine tumors (13 men, 11 women; mean age, 59.8 years). DCE MR imaging was performed at 3.0 T with a standard dose of gadoxetic acid and a three-dimensional sequence, with 48 sections of data acquired every 2.2 seconds for 5 minutes. For each patient, a plasma flow map was calculated by means of deconvolution and the model was fitted to six region-of-interest curves. Results were evaluated with goodness-of-fit analysis and, in normal-appearing liver tissue, by comparing perfusion parameters with those reported in the literature. Interobserver effects in the selection of arterial and venous input functions were assessed. With an arterial delay parameter, the model provided a good fit to all data. Values for arterial and venous plasma flow and extracellular volume in normal-appearing liver tissue were comparable to those in the literature. The mean intracellular uptake rate is 3.4/100/min with a standard deviation of 1.9/100/min The model also provided a good fit in all tumor data, producing high arterial flow fraction (87%) and lower uptake (1.7/100/min) . Bias due to observer-dependent differences in the selection of the input functions was negligible. The analysis of dynamic gadoxetic acid-enhanced MR images with the dual-inlet two-compartment uptake model presents a new and practical approach for measuring arterial and venous perfusion and hepatic function in a single acquisition.

18 October 2019 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
IMIosif Mendichovszky
Iosif Mendichovszky
PPPim Pullens
Pim Pullens
IDIlona Dekkers
Ilona Dekkers
FNFabio Nery
Fabio Nery
OBOctavia Bane
Octavia Bane
SSSteven Sourbron
Steven Sourbron
Purpose: The potential of renal MRI biomarkers has been increasingly recognised, but clinical translation requires more standardisation. The PARENCHIMA consensus project aims to develop and apply a process for generating technical recommendations on renal MRI. Methods: A task force was formed in July 2018 focused on five methods. A draft process for attaining consensus was distributed publicly for consultation and finalised at an open meeting (Prague, October 2018). Four expert panels completed surveys between October 2018 and March 2019, discussed results and refined the surveys at a face-to-face meeting (Aarhus, March 2019) and completed a second round (May 2019). Results: A seven-stage process was defined: (1) formation of expert panels; (2) definition of the context of use; (3) literature review; (4) collection and comparison of MRI protocols; (5) consensus generation by an approximate Delphi method; (6) reporting of results in vendor-neutral and vendor-specific terms; (7) ongoing review and updating. Application of the process resulted in 166 consensus statements. Conclusion: The process generated meaningful technical recommendations across very different MRI methods, while allowing for improvement and refinement as open issues are resolved. The results are likely to be widely supported by the renal MRI community and thereby promote more harmonisation.

19 October 2012 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
KSKazuhiro Saito
Kazuhiro Saito
JLJoseph Ledsam
Joseph Ledsam
SSSteven Sourbron
Steven Sourbron
JOJun Otaka
Jun Otaka
YAYoichi Araki
Yoichi Araki
KTKoichi Tokuuye
Koichi Tokuuye
Purpose: To evaluate liver function obtained by tracer-kinetic modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data acquired with a routine gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced protocol. Materials and Methods: Data were acquired from 25 cases of nonchronic liver disease and 94 cases of cirrhosis. DCE-MRI was performed with a dose of 0.025 mmol/kg Gd-EOB-DTPA injected at 2 mL/sec. A 3D breath-hold sequence acquired 5 volumes of 72 slices each: precontrast, double arterial phase, portal phase, and 4-minute postcontrast. Regions of interest (ROIs) were selected semiautomatically in the aorta, portal vein, and whole liver on a middle slice. A constrained dual-inlet two-compartment uptake model was fitted to the ROI curves, producing three parameters: intracellular uptake rate (UR), extracellular volume (Ve), and arterial flow fraction (AFF). Results: Median UR dropped from 4.46 10−2 min−1 in the noncirrhosis to 3.20 in Child–Pugh A (P = 0.001), and again to 1.92 in Child–Pugh B (P < 0.0001). Median Ve dropped from 6.64 mL 100 mL−1 in the noncirrhosis to 5.80 in Child–Pugh A (P = 0.01). Other combinations of Ve and AFF changes were not significant for any group. Conclusion: UR obtained from tracer kinetic analysis of a routine DCE-MRI has the potential to become a novel index of liver function. J. Magn. Reson. Imaging 2013;37:1109–1114.