15 May 2013 in NMR in Biomedicine
7 March 2011 in Magnetic Resonance in Medicine
The Tofts model (TM) and extended Tofts model (ETM) have become a standard for the analysis of dynamic contrast‐enhanced MRI. In this study, a mathematical analysis is used to identify exactly in which tissue types the Tofts models may be applied. The results show that the TM is accurate if and only if the tissue is weakly vascularised (small blood volume). The ETM is additionally accurate in highly perfused tissues (high blood flow). In tissues that are highly vascularised, or where tracer exchange is very fast or very slow, TM and ETM accurately fit the data but lead to a misinterpretation of the parameters. In tissue types with intermediate vascularity, perfusion and tracer exchange, neither model offers a good fit to the tissue concentrations. A good fit can be obtained with a measured input function by reducing the temporal resolution, but this does not improve the accuracy of the parameters. In conclusion, the Tofts models only produce reliable parameter values if the tissue is weakly vascularized (TM or ETM) or highly perfused (ETM). Without prior knowledge that at least one of these constraints is fulfilled, the physiological interpretation of the values produced by the Tofts models is unclear. Magn Reson Med, 2011.
1 December 2010 in European Journal of Radiology
18 October 2019 in Magnetic Resonance Materials in Physics, Biology and Medicine
Purpose: The potential of renal MRI biomarkers has been increasingly recognised, but clinical translation requires more standardisation. The PARENCHIMA consensus project aims to develop and apply a process for generating technical recommendations on renal MRI. Methods: A task force was formed in July 2018 focused on five methods. A draft process for attaining consensus was distributed publicly for consultation and finalised at an open meeting (Prague, October 2018). Four expert panels completed surveys between October 2018 and March 2019, discussed results and refined the surveys at a face-to-face meeting (Aarhus, March 2019) and completed a second round (May 2019). Results: A seven-stage process was defined: (1) formation of expert panels; (2) definition of the context of use; (3) literature review; (4) collection and comparison of MRI protocols; (5) consensus generation by an approximate Delphi method; (6) reporting of results in vendor-neutral and vendor-specific terms; (7) ongoing review and updating. Application of the process resulted in 166 consensus statements. Conclusion: The process generated meaningful technical recommendations across very different MRI methods, while allowing for improvement and refinement as open issues are resolved. The results are likely to be widely supported by the renal MRI community and thereby promote more harmonisation.
19 October 2012 in Journal of Magnetic Resonance Imaging
Purpose: To evaluate liver function obtained by tracer-kinetic modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data acquired with a routine gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced protocol. Materials and Methods: Data were acquired from 25 cases of nonchronic liver disease and 94 cases of cirrhosis. DCE-MRI was performed with a dose of 0.025 mmol/kg Gd-EOB-DTPA injected at 2 mL/sec. A 3D breath-hold sequence acquired 5 volumes of 72 slices each: precontrast, double arterial phase, portal phase, and 4-minute postcontrast. Regions of interest (ROIs) were selected semiautomatically in the aorta, portal vein, and whole liver on a middle slice. A constrained dual-inlet two-compartment uptake model was fitted to the ROI curves, producing three parameters: intracellular uptake rate (UR), extracellular volume (Ve), and arterial flow fraction (AFF). Results: Median UR dropped from 4.46 10−2 min−1 in the noncirrhosis to 3.20 in Child–Pugh A (P = 0.001), and again to 1.92 in Child–Pugh B (P < 0.0001). Median Ve dropped from 6.64 mL 100 mL−1 in the noncirrhosis to 5.80 in Child–Pugh A (P = 0.01). Other combinations of Ve and AFF changes were not significant for any group. Conclusion: UR obtained from tracer kinetic analysis of a routine DCE-MRI has the potential to become a novel index of liver function. J. Magn. Reson. Imaging 2013;37:1109–1114.