Paul Porter

Paul Porter

Auto-generated profile, based on publicly available information

Paul Porter

Joondalup Health Campus

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 1998 in New England Journal of Medicine
Verified
Journal Article
Open access
PDF file
TJTimothy W. Jones
Timothy W. Jones
PPPaul Porter
Paul Porter
RSRobert S. Sherwin
Robert S. Sherwin
EDElizabeth A. Davis
Elizabeth A. Davis
POPeter O'Leary
Peter O'Leary
WTWilliam V. Tamborlane
William V. Tamborlane
In patients with type I diabetes mellitus, hypoglycemia occurs commonly during sleep and is frequently asymptomatic. This raises the question of whether sleep is associated with reduced counterregulatory-hormone responses to hypoglycemia. We studied the counterregulatory-hormone responses to insulin-induced hypoglycemia in eight adolescent patients with type I diabetes and six age-matched normal subjects when they were awake during the day, asleep at night, and awake at night. In each study, the plasma glucose concentration was stabilized for 60 minutes at approximately 100 mg per deciliter (5.6 mmol per liter) and then reduced to 50 mg per deciliter (2.8 mmol per liter) and maintained at that concentration for 40 minutes. Plasma free insulin, epinephrine, norepinephrine, cortisol, and growth hormone were measured frequently during each study. Sleep was monitored by polysomnography. The plasma glucose and free insulin concentrations were similar in both groups during all studies. During the studies when the subjects were asleep, no one was awakened during the hypoglycemic phase, but during the final 30 minutes of the studies when the subjects were awake both the patients with diabetes and the normal subjects had symptoms of hypoglycemia. In the patients with diabetes, plasma epinephrine responses to hypoglycemia were blunted when they were asleep (mean [±SE] peak plasma epinephrine concentration, 70±14 pg per milliliter [382±76 pmol per liter]; P=0.3 for the comparison with base line), as compared with when they were awake during the day or night (238±39 pg per milliliter [1299±213 pmol per liter], P=0.004 for the comparison with base line, and 296±60 pg per milliliter [1616±327 pmol per liter], P=0.004, respectively). The patients' plasma norepinephrine responses were also reduced during sleep, whereas their plasma cortisol concentrations did not increase and their plasma growth hormone concentrations increased slightly. The patterns of counterregulatory-hormone responses in the normal subjects were similar. Sleep impairs counterregulatory-hormone responses to hypoglycemia in patients with diabetes and normal subjects.

6 June 2019 in Respiratory Research
Verified
Journal Article
Open access
PDF file
PPPaul Porter
Paul Porter
UAUdantha Abeyratne
Udantha Abeyratne
VSVinayak Swarnkar
Vinayak Swarnkar
JTJamie Tan
Jamie Tan
TNTi-Wan Ng
Ti-Wan Ng
Phillip Roy DellaPhillip Roy Della
Phillip Roy Della
The differential diagnosis of paediatric respiratory conditions is difficult and suboptimal. Existing diagnostic algorithms are associated with significant error rates, resulting in misdiagnoses, inappropriate use of antibiotics and unacceptable morbidity and mortality. Recent advances in acoustic engineering and artificial intelligence have shown promise in the identification of respiratory conditions based on sound analysis, reducing dependence on diagnostic support services and clinical expertise. We present the results of a diagnostic accuracy study for paediatric respiratory disease using an automated cough-sound analyser. We recorded cough sounds in typical clinical environments and the first five coughs were used in analyses. Analyses were performed using cough data and up to five-symptom input derived from patient/parent-reported history. Comparison was made between the automated cough analyser diagnoses and consensus clinical diagnoses reached by a panel of paediatricians after review of hospital charts and all available investigations. A total of 585 subjects aged 29 days to 12 years were included for analysis. The Positive Percent and Negative Percent Agreement values between the automated analyser and the clinical reference were as follows: asthma (97, 91%); pneumonia (87, 85%); lower respiratory tract disease (83, 82%); croup (85, 82%); bronchiolitis (84, 81%). Conclusion: The results indicate that this technology has a role as a high-level diagnostic aid in the assessment of common childhood respiratory disorders. Australian and New Zealand Clinical Trial Registry (retrospective) - ACTRN12618001521213 : 11.09.2018.

1 March 1997 in The Journal of Pediatrics
Verified
Journal Article
Closed access
PPPaul A. Porter
Paul A. Porter
BKBarbara Keating
Barbara Keating
GBGeoffrey Byrne
Geoffrey Byrne
TJTimothy W. Jones
Timothy W. Jones

21 June 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Roneel SharanRoneel Sharan
Roneel Sharan
UAUdantha Ranjit Abeyratne
Udantha Ranjit Abeyratne
VSVinayak R. Swarnkar
Vinayak R. Swarnkar
PPPaul Porter
Paul Porter
Objective: Croup, a respiratory tract infection common in children, causes an inflammation of the upper airway restricting normal breathing and producing cough sounds typically described as seal-like "barking cough". Physicians use the existence of barking cough as the defining characteristic of croup. This work aims to develop automated cough sound analysis methods to objectively diagnose croup. Methods: In automating croup diagnosis, we propose the use of mathematical features inspired by the human auditory system. In particular, we utilize the cochleagram for feature extraction, a time-frequency representation where the frequency components are based on the frequency selectivity property of the human cochlea. Speech and cough share some similarities in the generation process and physiological wetware used. As such, we also propose the use of mel-frequency cepstral coefficients which has been shown to capture the relevant aspects of the short-term power spectrum of speech signals. Feature combination and backward sequential feature selection are also experimented with. Experimentation is performed on cough sound recordings from patients presenting various clinically diagnosed respiratory tract infections divided into croup and non-croup. The dataset is divided into training and test sets of 364 and 115 patients, respectively, with automatically segmented cough sound segments. Results: Croup and non-croup patient classification on the test dataset with the proposed methods achieve a sensitivity and specificity of 92.31% and 85.29%, respectively. Conclusion: Experimental results show significant improvement in automatic croup diagnosis against earlier methods. Significance: This work has the potential to automate croup diagnosis based solely on cough sound analysis.

1 September 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
Roneel SharanRoneel Sharan
Roneel Sharan
UAUdantha R Abeyratne
Udantha R Abeyratne
VSVinayak R Swarnkar
Vinayak R Swarnkar
SCScott Claxton
Scott Claxton
CHCraig Hukins
Craig Hukins
PPPaul Porter
Paul Porter
Spirometry is a commonly used method of measuring lung function. It is useful in the definitive diagnosis of diseases such as asthma and chronic obstructive pulmonary disease (COPD). However, spirometry requires cooperative patients, experienced staff, and repeated testing to ensure the consistency of measurements. There is discomfort associated with spirometry and some patients are not able to complete the test. In this paper, we investigate the possibility of using cough sound analysis for the prediction of spirometry measurements. Our approach is based on the premise that the mechanism of cough generation and the forced expiratory maneuver of spirometry share sufficient similarities enabling this prediction. Using an iPhone, we collected mostly voluntary cough sounds from 322 adults presenting to a respiratory function laboratory for pulmonary function testing. Subjects had the following diagnoses: obstructive, restrictive, or mixed pattern diseases, or were found to have no lung disease along with normal spirometry. The cough sounds were automatically segmented using the algorithm described in Sharan et al (2018 IEEE Trans. Biomed. Eng.). We then represented cough sounds with various cough sound descriptors and built linear and nonlinear regression models connecting them to spirometry parameters. Augmentation of cough features with subject demographic data is also experimented with. The dataset was divided into 272 training subjects and 50 test subjects for experimentation. The performance of the auto-segmentation algorithm was evaluated on 49 randomly selected subjects from the overall dataset with a sensitivity and PPV of 84.95% and 98.51%, respectively. Our regression models achieved a root mean square error (and correlation coefficient) for standard spirometry parameters FEV1, FVC, and FEV1/FVC of 0.593L (0.810), 0.725L (0.749), and 0.164 (0.547), respectively, on the test dataset. In addition, we could achieve sensitivity, specificity, and accuracy of 70% or higher by applying the GOLD standard for COPD diagnosis on the estimated spirometry test results. The experimental results show high positive correlation in predicting FEV1 and FVC and moderate positive correlation in predicting FEV1/FVC. The results show possibility of predicting spirometry results using cough sound analysis.

1 August 1996 in Archives of Disease in Childhood
Verified
Journal Article
Open access
PDF file
PPP A Porter
P A Porter
GBG Byrne
G Byrne
SSS Stick
S Stick
TJT W Jones
T W Jones
OBJECTIVE: To determine the effect of nocturnal hypoglycaemia on sleep architecture in adolescents with insulin dependent diabetes mellitus (IDDM). DESIGN: 20 adolescents with IDDM (mean age 12.8 years, mean glycated haemoglobin (HbA1c) 8.9%) were studied on one night. Plasma glucose was measured every 30 minutes and cortisol and growth hormone levels every 60 minutes. Sleep was recorded using standard polysomnographic montages, and sleep architecture was analysed for total sleep time, stages 1-4, rapid eye movement, fragmentation, and arousals. RESULTS: Six subjects (30%) became hypoglycaemic (five subjects < 2.5 mmol/l), with one being symptomatic. There were no differences in age, HbA1c, duration of diabetes, or insulin regimen between hypoglycaemic and non-hypoglycaemic subjects. Hypoglycaemia was not predicted by glucose measurements before bed. There was no detectable rise in plasma cortisol or growth hormone concentrations during hypoglycaemia. Sleep architecture was not disturbed by nocturnal hypoglycaemia with no differences found in sleep stages, fragmentation, or arousals. CONCLUSIONS: Nocturnal hypoglycaemia is a common and usually asymptomatic complication of treatment in adolescents with IDDM. Moderate hypoglycaemia has not been shown to affect sleep architecture adversely. These findings are consistent with, and may explain, the observation that severe hypoglycaemia, with consequent seizure activity, is more common at night than during the day. Counterregulatory hormone responses to nocturnal hypoglycaemia may be less marked than with similar degrees of diurnal hypoglycaemia.