21 November 2024 in Plasma Physics and Controlled Fusion
During deuterium campaigns on the heliotron large helical device (LHD), ITER pressure gauges with different cathode materials were used to measure the neutral pressure in the sub-divertor region. Throughout these campaigns, it was observed that the performance of a LaB6 cathode was unsatisfactory during deuterium operation. Conversely, measurements taken with pressure gauges with a ZrC cathode performed well throughout the deuterium pulses. The ITER pressure gauge with the ZrC cathode could be operated with a very high electron current of 800 µA, thus improving the lower detection limit of the neutral pressure in LHD. With this design it was also possible to avoid jumps in the ion current within strong magnetic fields, improving the accuracy of the measurement from 15% uncertainty to 5%. These features allowed very precise neutral pressure measurements to be made in a fusion device with magnetic confinement. The problems with the lifetime of the ZrC cathode reported in Mackel et al (2023 Fusion Eng. Des. 189 113439) were not relevant here, as the total runtime in the magnetic field was about 60 h, less than the expected lifetime of the cathode of 350 h.
1 July 2024 in Review of Scientific Instruments
Hot cathode ionization gauges will measure the neutral gas pressure in the vacuum vessel of ITER. Overall, 52 gauge heads based on the concept of the ASDEX pressure gauge but using novel ZrC emitters are located in the divertor, in equatorial ports and in pumping ducts. The initial lifetime tests of the novel gauge design have raised the concern that the pyrolytic graphite used to indirectly heat the ceramic ZrC emitter erodes too fast during operation. This effect might limit the lifetime of the gauges below the limits acceptable according to the inherent availability (ignoring operational delays) requirement of 99.8% for the diagnostic system over the lifetime of ITER. Long term operation tests have been performed using 0.1 mm thick W, Ir, and Mo foils as an interlayer between the pyrolytic graphite and the ZrC within a constant atmosphere of 20 Pa H2. The longest lifetime of 860 h has been achieved with the Ir foil. Subsequent vibration tests applying accelerations on a shaker with magnitudes typical for seismic and ITER disruption loads demonstrated that the emitter can survive such demanding loads even after far-progressed erosion of the pyrolytic graphite. Additional ON/OFF cycle tests demonstrated that the gauge is still fully operational. In combination with a revision and consolidation of the operational plan and the reliability, accessibility, maintainability, and inspectability (RAMI) analysis, ITER’s inherent availability requirement for the diagnostic system could be demonstrated successfully.