Garima Thakur

Garima Thakur

Auto-generated profile, based on publicly available information

Garima Thakur

Preclinical Manufacturing and Process Development, Regeneron Pharmaceuticals Inc Tarrytown New York USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2022 in Trends in Biotechnology
Verified
Journal Article
Closed access
ARAnurag Rathore
Anurag Rathore
SNSaxena Nikita
Saxena Nikita
GTGarima Thakur
Garima Thakur
SMSomesh Mishra
Somesh Mishra

3 July 2022 in Computers & Chemical Engineering
Verified
Journal Article
Closed access
SNSaxena Nikita
Saxena Nikita
GTGarima Thakur
Garima Thakur
NJNaveen G Jesubalan
Naveen G Jesubalan
AKAmey Kulkarni
Amey Kulkarni
VYVinesh B. Yezhuvath
Vinesh B. Yezhuvath
ARAnurag Rathore
Anurag Rathore

28 September 2022 in Biotechnology and Bioengineering
Verified
Journal Article
Closed access
ARAnurag Rathore
Anurag Rathore
GTGarima Thakur
Garima Thakur
NKNikhil Kateja
Nikhil Kateja

3 March 2025 in Molecular Therapy - Methods & Clinical Development
Verified
Journal Article
Open access
GTGarima Thakur
Garima Thakur
SMSheldon Mink
Sheldon Mink
AGAna J. Garcia
Ana J. Garcia
HBHanne Bak
Hanne Bak
ATAndrew D. Tustian
Andrew D. Tustian
A critical step in manufacturing of adeno-associated viral vectors (AAVs) is separation of full and empty capsids. The current consensus in the industry is that it is critical to enrich for full capsids to deliver safer and more efficacious drug products to patients. Anion-exchange chromatography is well established as a scalable method for full/empty separations. However, due to the poor peak resolution, especially at process-scale column loadings, anion exchange gradient methods are unlikely to be able to achieve >70% full capsids in cases of 5%-20% full capsids in the load material, as the low starting percent full truncates the yield and purity of the elution pools. To overcome this challenge, we propose a "two-pass" anion exchange method which is effective in maximally enriching for full capsids. The method consists of a "first-pass" elution using a series of microstep increases in conductivity to remove the bulk of the empty capsids, followed by a "second-pass" elution in which selected enriched fractions from the first pass are reloaded onto the chromatography column for a final, targeted enrichment. The two-pass AEX strategy has been tested on four serotypes (AAV1, AAV2, AAV8, and AAV9) and demonstrated at pilot and production scale.

7 January 2023 in Journal of Chromatography A
Verified
Journal Article
Closed access
NNNitika Nitika
Nitika Nitika
GTGarima Thakur
Garima Thakur
ARAnurag Rathore
Anurag Rathore

17 September 2022 in Journal of Chromatography A
Verified
Journal Article
Closed access
GTGarima Thakur
Garima Thakur
VBVikrant Bansode
Vikrant Bansode
ARAnurag Rathore
Anurag Rathore